{"product_id":"ge-is215wetah1a-mark-vie-wind-top-box-a-module-board","title":"GE IS215WETAH1A Mark VIe Wind Top Box A Module Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS215WETAH1A\u003c\/strong\u003e functions as a dedicated \u003cstrong\u003eTop Box A Module Board\u003c\/strong\u003e designed for integration within the Mark VIe Wind turbine control system architecture. This circuit board assembly is primarily located within the turbine's upper drive assembly loop, providing essential local monitoring and control node synchronization. The hardware configuration features a special assembly version that incorporates a SCOM grounding output terminal structure, engineered to manage auxiliary voltage dissipation and electrical isolation. To ensure operational survivability in harsh wind engine environments, the entire surface area of the printed circuit board is sealed with an exhaustive, chemically applied conformal coating that completely envelopes all onboard hardware sub-components.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSpecialized assembly design containing a integrated SCOM grounding terminal for voltage stabilization.\u003c\/li\u003e\n\u003cli\u003eFactory-applied conformal coating covering all components to prevent moisture and particulate degradation.\u003c\/li\u003e\n\u003cli\u003eDesigned as a conversational shorthand variant under the WETA functional acronym.\u003c\/li\u003e\n\u003cli\u003ePart of the Group 1 classification within the Mark VIe Wind control series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWind turbine main nacelle Top Box drive control networks.\u003c\/li\u003e\n\u003cli\u003eLocalized rotor or pitch control loop automation.\u003c\/li\u003e\n\u003cli\u003eMulti-megawatt wind engine electrical distribution monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Energy (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIS215WETAH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTop Box A Module Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMark VIe Wind\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Acronym\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWETA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePCB Coating Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Revision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries Grouping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturing Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSalem, Virginia, USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSCOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrounding Output Terminal for Voltage Storage and Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Grounding:\u003c\/strong\u003e Technicians must utilize a verified electrostatic discharge (ESD) wrist strap properly bonded to cabinet ground prior to unpacking or adjusting the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Connection:\u003c\/strong\u003e Ensure the SCOM grounding output terminal is securely integrated into the main chassis grounding bus to provide continuous over-voltage protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e Verify the completeness of the conformal coating layer along board edges before mounting inside the Top Box enclosure to prevent condensation short-circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Mounting:\u003c\/strong\u003e Secure the board assembly within its designated slot inside the wind turbine drive housing using correct torque specifications to prevent vibration detachment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695411327339,"sku":"IS215WETAH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is215wetah1a-top-box-a-module-board-iyzphz3wry1_efb18e70-7608-41c2-b0c1-71d41a3ca91c.jpg?v=1766135071","url":"https:\/\/www.plcprotech.com\/products\/ge-is215wetah1a-mark-vie-wind-top-box-a-module-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}