{"product_id":"ge-is220ypros1a-mark-vies-safety-discrete-i-o-pack","title":"GE IS220YPROS1A Mark VIeS Safety Discrete I\/O Pack","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS220YPROS1A\u003c\/strong\u003e is a safety discrete input\/output pack designed for the Mark VIeS Safety Control System. This high-reliability component interfaces dual or triple redundant safety discrete inputs and manages safety-critical discrete outputs, making it ideal for emergency shutdown (ESD) systems, burner management systems (BMS), and fire and gas detection applications. It provides direct network connectivity via dual Ethernet ports to the control system layer, ensuring fast, deterministic communication of safety status. The \u003cstrong\u003eIS220YPROS1A\u003c\/strong\u003e ensures complete electrical isolation between control logic and field-side instrumentation, maximizing system availability and fault tolerance in critical industrial processes.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual-redundant Ethernet ports for reliable ControlST network communication.\u003c\/li\u003e\n\u003cli\u003eDesigned specifically for functional safety applications within Mark VIeS architectures.\u003c\/li\u003e\n\u003cli\u003eSupports high-density discrete input monitoring and supervised discrete outputs.\u003c\/li\u003e\n\u003cli\u003eIntegrated diagnostics for real-time monitoring of internal hardware and loop integrity.\u003c\/li\u003e\n\u003cli\u003eOn-board processing filters input signals to eliminate contact bounce and electrical noise.\u003c\/li\u003e\n\u003cli\u003eCompact, rugged form factor optimized for standard industrial control cabinet installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmergency Shutdown (ESD) Systems\u003c\/li\u003e\n\u003cli\u003eBurner Management Systems (BMS)\u003c\/li\u003e\n\u003cli\u003eFire and Gas Monitoring Networks\u003c\/li\u003e\n\u003cli\u003eHigh-Integrity Pressure Protection Systems (HIPPS)\u003c\/li\u003e\n\u003cli\u003eCritical Turbine and Generator Interlock Controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 100%; height: 293.907px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 36.6602%; height: 19.5938px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 60.0065%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.6602%; height: 19.5938px;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0065%; height: 19.5938px;\"\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.6602%; height: 19.5938px;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0065%; height: 19.5938px;\"\u003eIS220YPROS1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.6602%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0065%; height: 19.5938px;\"\u003eSafety Discrete I\/O Pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.6602%; height: 19.5938px;\"\u003e\u003cstrong\u003eControl System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0065%; height: 19.5938px;\"\u003eMark VIeS Safety Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.6602%; height: 39.1875px;\"\u003e\u003cstrong\u003eAmbient Temperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0065%; height: 39.1875px;\"\u003e-30 to 65 degC (-22 to 149 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.6602%; height: 19.5938px;\"\u003e\u003cstrong\u003eNetwork Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0065%; height: 19.5938px;\"\u003eDual 100Base-TX Ethernet channels (IONet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.6602%; height: 19.5938px;\"\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0065%; height: 19.5938px;\"\u003eRedundant or single safety discrete inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.6602%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0065%; height: 19.5938px;\"\u003eSupervised discrete outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 36.6602%; height: 39.1875px;\"\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0065%; height: 39.1875px;\"\u003eLED diagnostics for Power, Link, and Fault conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.6602%; height: 19.5938px;\"\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0065%; height: 19.5938px;\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.6602%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0065%; height: 19.5938px;\"\u003e8.26 cm x 4.19 cm x 12.07 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 36.6602%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0065%; height: 19.5938px;\"\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Installation:\u003c\/strong\u003e Securely mount the I\/O pack onto a standard TS35 DIN rail. Ensure the locking mechanism engages completely to prevent movement caused by mechanical vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a low-impedance connection between the mounting rack\/DIN rail and the primary system safety ground busbar to mitigate EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling and Ventilation:\u003c\/strong\u003e Maintain at least 50 mm of unobstructed space above and below the module to facilitate natural convection cooling. Do not exceed the ambient temperature rating of 65 degC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route low-voltage Ethernet networks and signal lines in separate wire ducts away from high-voltage AC power lines to prevent signal cross-talk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Termination:\u003c\/strong\u003e Connect both Ethernet ports to designated network switches (IONet switches) to achieve full communications redundancy.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695420928363,"sku":"IS220YDIAS1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is220ydias1a-discrete-contact-input-i-o-module-iuftmw4kjxn_355e1b87-d856-4583-bcdd-d2ecfbec623e.jpg?v=1766135411","url":"https:\/\/www.plcprotech.com\/products\/ge-is220ypros1a-mark-vies-safety-discrete-i-o-pack","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}