{"product_id":"ge-mark-vie-is220prtdh1a-resistance-temperature-device-input-module","title":"GE Mark VIe IS220PRTDH1A Resistance Temperature Device Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS220PRTDH1A\u003c\/strong\u003e is a \u003cstrong\u003eResistance Temperature Device (RTD) Input Module\u003c\/strong\u003e designed for General Electric's \u003cstrong\u003eMark VIe Speedtronic\u003c\/strong\u003e turbine control system. Functioning as an \u003cstrong\u003eI\/O pack\u003c\/strong\u003e (Input\/Output pack), this device interfaces directly with a terminal board to digitize analog temperature measurements from industrial processes. It provides high-density temperature monitoring across \u003cstrong\u003eeight channels\u003c\/strong\u003e, accepting inputs exclusively from resistive simple apparatus such as RTDs.\u003c\/p\u003e\n\u003cp\u003eThe module features a \u003cstrong\u003econformal PCB coating\u003c\/strong\u003e to ensure long-term reliability in harsh operating conditions, protecting the internal circuitry from environmental contaminants. Engineered for critical control loops, the \u003cstrong\u003eIS220PRTDH1A\u003c\/strong\u003e communicates over a redundant network via dual onboard \u003cstrong\u003eEthernet ports\u003c\/strong\u003e to deliver real-time thermal data to the primary controller, making it suitable for industrial gas and steam turbine management.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEight-Channel Input\u003c\/strong\u003e: Supports up to 8 independent RTD sensor connections for comprehensive thermal monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coated PCB\u003c\/strong\u003e: Thin layer of chemically applied protection Safeguards the entire base circuit board against moisture, dust, and chemical contaminants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Revision A\u003c\/strong\u003e: Incorporates targeted design enhancements to optimize core module performance and reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Power Supply\u003c\/strong\u003e: Features an onboard power supply unit, reducing reliance on external power distribution components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual Diagnostics\u003c\/strong\u003e: Front-panel LED indicators provide immediate status monitoring for power, attention (ATTN), and link activity on both Ethernet ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Certified\u003c\/strong\u003e: Approved for installation in classified locations when paired with compatible, specified terminal boards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial gas turbine thermal monitoring and control loops\u003c\/li\u003e\n\u003cli\u003eSteam turbine bearing and stator temperature supervision\u003c\/li\u003e\n\u003cli\u003eGeneral Electric \u003cstrong\u003eMark VIe\u003c\/strong\u003e control system retrofits and expansions\u003c\/li\u003e\n\u003cli\u003eHazardous location process temperature data acquisition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIS220PRTDH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Acronym\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePRTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMark VIe Speedtronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssembly Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIS220 Special Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Grouping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRevision Total\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Revision (Functional Revision A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTop and Bottom-Vented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual Ethernet Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.40 pounds (unpacked)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34 x 18 x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eTerminal Board Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS220PRTDH1A\u003c\/strong\u003e must be paired with approved terminal boards to maintain system compliance and safety. For certified applications, utilize only the following compatible boards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIS200TRTDH2D\u003c\/li\u003e\n\u003cli\u003eIS200SRTDH1A\u003c\/li\u003e\n\u003cli\u003eIS200SRTDH2A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWiring and Cable Routing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnect only resistive simple apparatus, such as standard RTD sensors, to the input channels. Do not connect active voltage or current sources to these inputs.\u003c\/li\u003e\n\u003cli\u003eEnsure all field cabling features insulation ratings that strictly comply with local electrical codes and industrial standards.\u003c\/li\u003e\n\u003cli\u003eRoute signal cables away from high-voltage AC lines or high-frequency switching cables to minimize electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVenting and Enclosure Positioning\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module within a clean, secure enclosure that provides sufficient protection from environmental debris.\u003c\/li\u003e\n\u003cli\u003eMaintain unobstructed airflow around the top and bottom vents of the chassis to prevent thermal buildup during continuous operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE Marked\u003c\/li\u003e\n\u003cli\u003eUL Listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the conformal coating on the circuit board protect against?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conformal PCB coat is a thin, chemically applied protective layer covering the entire base circuit board. It shields the internal components against humidity, dust, and airborne contaminants typical of industrial turbine environments, preventing tracking faults and corrosion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the revision status on this specific model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe designated functional revision A represents an optimized engineering update that directly enhances the baseline operation, signal stability, and hardware performance of the input module compared to the parent non-A variant.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is status monitoring handled directly on the hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module front panel provides real-time diagnostic status via hardware LEDs. These include dedicated indicators for the two Ethernet communication links, a Power LED to verify active internal voltage, and an Attention (ATTN) LED to signal system faults or configuration mismatches.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695414112619,"sku":"IS220PRTDH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is220prtdh1a-resistance-temperature-device-w5ig3m0k3ep_7291f57b-7d70-4f86-98db-d9e4e82b5bc3.jpg?v=1766135174","url":"https:\/\/www.plcprotech.com\/products\/ge-mark-vie-is220prtdh1a-resistance-temperature-device-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}