{"product_id":"ge-multilin-489-p5-lo-a20-e-generator-management-relay","title":"GE Multilin 489-P5-LO-A20-E Generator Management Relay","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin 489-P5-LO-A20-E Generator Management Relay\u003c\/strong\u003e is a digital protection, monitoring, and metering device designed for small to medium-sized synchronous or induction generators operating at 25 Hz, 50 Hz, or 60 Hz. As a member of the SR family of relays, this system features a draw-out construction and delivers advanced protection algorithms, including generator stator differential protection and 100% stator ground fault detection.\u003c\/p\u003e\n\u003cp\u003eThe unit manages thermal modeling using 12 RTD inputs, processes vibration\/speed inputs via 4 analog transducer channels, and supports continuous operational logging with oscillography and event recording. Integration with industrial DCS and SCADA architectures is facilitated through front RS232, dual RS485, and 10BaseT Ethernet communications supporting Modbus RTU, Modbus TCP\/IP, and DNP 3.0 protocols.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed dual slope differential protection with CT saturation detection algorithms.\u003c\/li\u003e\n\u003cli\u003e100% stator ground protection via overvoltage and adaptive voltage differential elements.\u003c\/li\u003e\n\u003cli\u003eThermal overload modeling incorporating current unbalance biasing and RTD thermal feedback.\u003c\/li\u003e\n\u003cli\u003e12 field-programmable RTD inputs supporting Platinum, Nickel, and Copper sensors with RTD voting functionality.\u003c\/li\u003e\n\u003cli\u003e4 isolated 4 to 20 mA analog transducer inputs for bearing vibration and speed tracking.\u003c\/li\u003e\n\u003cli\u003e4 active 4 to 20 mA analog outputs for parameter signaling to PLCs.\u003c\/li\u003e\n\u003cli\u003eIntegrated oscillography capturing 12 samples per cycle for up to 128 cycles.\u003c\/li\u003e\n\u003cli\u003eTime-synchronized event recording up to 256 events via IRIG-B clock inputs.\u003c\/li\u003e\n\u003cli\u003eFront panel interface featuring a 40-character display, numeric keypad, and 22 status LEDs.\u003c\/li\u003e\n\u003cli\u003eLow-range control power supply accepting 20 to 60 VDC or 20 to 48 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary or backup generator protection for synchronous and induction machines.\u003c\/li\u003e\n\u003cli\u003eStator, bearing, and excitation monitoring in cogeneration facilities.\u003c\/li\u003e\n\u003cli\u003eIndustrial power generation systems operating at 25 Hz, 50 Hz, or 60 Hz nominal frequencies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification \/ Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e489\u003c\/td\u003e\n\u003ctd\u003eGenerator Protection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase Current Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eP5\u003c\/td\u003e\n\u003ctd\u003e5 A phase CT secondaries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLO\u003c\/td\u003e\n\u003ctd\u003eDC: 24 to 60 V; AC: 20 to 48 V @ 48 to 62 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalogue Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA20\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnhancements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003eEnhanced display, larger LCD, improved keypad plus 10BaseT Ethernet Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e[None]\u003c\/td\u003e\n\u003ctd\u003eStandard (Harsh environment conformal coating not selected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Vernova \/ Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase Current Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A Phase CT Secondaries (Conversion Range: 0.02 to 20 x CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Power Supply (LO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC: 20 to 60 V DC; AC: 20 to 48 V AC at 48 to 62 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 VA maximum, 25 VA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Active 4 to 20 mA channels (Accuracy: ±1% of full scale, Max Load: 1200 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Transducer Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Channels; 0 to 1 mA, 0 to 20 mA, or 4 to 20 mA (Impedance: 226 Ω ±10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRTD Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Inputs; 3-wire 100 Ω Platinum, 100 Ω Nickel, 120 Ω Nickel, 10 Ω Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 Opto-isolated inputs (Dry contact \u0026lt; 400 Ω); Sensor supply: +24 V DC at 20 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Relays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 Electromechanical Form C contacts (10 A resistive at 120\/250 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase Voltage Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVT Secondary: 200 V AC full-scale; Max continuous: 280 V AC; Burden: \u0026gt; 500 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral Voltage Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVT Secondary: 100 V AC full-scale; Max continuous: 280 V AC; Burden: \u0026gt; 500 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Communications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x Front RS232 (9600 baud); 2 x Rear RS485 (300 to 19200 baud)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x 10Mbps Copper RJ45 Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus RTU, Modbus TCP\/IP, DNP 3.0 Level 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 95% non-condensing at 55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAltitude \u0026amp; Pollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 2000 m; Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA2 - A4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD #1 (Compensation, Return, Hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA5 - A7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD #2 (Compensation, Return, Hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA8 - A10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD #3 (Compensation, Return, Hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA11 - A13\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD #4 (Compensation, Return, Hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA14 - A16\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD #5 (Compensation, Return, Hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA17 - A19\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD #6 (Compensation, Return, Hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB1 - B3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary RS485 Interface (+, -, COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB4 - B11\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Outputs 1 to 4 (+, - per output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB12 - B19\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Inputs 1 to 4 (+24V, +, - per input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB20 - B21\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Inputs COM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD1 - D3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD #7 (Compensation, Return, Hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD4 - D6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD #8 (Compensation, Return, Hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD7 - D9\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD #9 (Compensation, Return, Hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD10 - D12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD #10 (Compensation, Return, Hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD13 - D15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD #11 (Compensation, Return, Hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD16 - D18\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD #12 (Compensation, Return, Hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD19 - D21\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAssignable Digital Inputs 1 to 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD22 - D25\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAssignable Digital Inputs 4 to 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD26\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch +24V DC Access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD27\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccess Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD28\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBreaker Status Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE1 - E12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput Relays R1 Trip, R2 Aux, R3 Aux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eF1 - F12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput Relays R4 Aux, R5 Alarm, R6 In-Service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eG1 - G3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Current Inputs Phase A (16\/5A, 1A\/COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eG4 - G6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Current Inputs Phase B (16\/5A, 1A\/COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eG7 - G9\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Current Inputs Phase C (16\/5A, 1A\/COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eG10 - G12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl Power Inputs (+\/L, -\/N, Ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eH1 - H3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGround Current Inputs (16\/5A, 1A\/COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eH4 - H6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral CT Inputs (16\/5A, 1A\/COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eH7 - H9\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Voltage Sensing (Va, Vb, Vc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eH10 - H12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage Sensing Neutral \/ Open Delta Connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect safety ground and filter ground terminals independently to the main station ground bus to satisfy noise rejection and safety standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Safeguards:\u003c\/strong\u003e Ensure CT connections pass through automatic shorting terminals before servicing or removing the draw-out unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Power Matching:\u003c\/strong\u003e Confirm that the supply voltage matches the low-voltage range (20 to 60 VDC \/ 20 to 48 VAC) prior to applying power to terminals G10-G12.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Interference Mitigation:\u003c\/strong\u003e Route RTD and analog transducer signal cables using twisted-pair shielded conductors, grounding the shields exclusively at the designated shield terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Lines:\u003c\/strong\u003e Terminate RS485 networks with 120-ohm resistors and 1 nF capacitors at both ends of the loop.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eISO:\u003c\/strong\u003e Manufactured under an ISO9001 registered system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA\/UL:\u003c\/strong\u003e Certified to UL508, UL1053, and CSA C22.2 No. 14 standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to EN60255-5 and EN50263 standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType Tests:\u003c\/strong\u003e Complies with IEC 61000-4 series, EN60255 series, IEEE\/ANSI C37.90.1, C37.90.3, and CISPR11\/22 requirements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53644035391851,"sku":"489-P5-LO-A20-E","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/489.jpg?v=1785589818","url":"https:\/\/www.plcprotech.com\/products\/ge-multilin-489-p5-lo-a20-e-generator-management-relay","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}