{"product_id":"ge-multilin-760-p1-g1-s1-hi-a20-r-multilin-feeder-management-relay","title":"GE Multilin 760-P1-G1-S1-HI-A20-R Multilin Feeder Management Relay","description":"\u003cp\u003eGE Multilin \u003cstrong\u003e760-P1-G1-S1-HI-A20-R\u003c\/strong\u003e is a digital protection relay engineered for the comprehensive management, primary protection, and control of distribution feeders. This feeder protection system incorporates advanced overcurrent protection, voltage monitoring, and metering capabilities within a draw-out construction. It features full integration with the \u003cstrong\u003eEnerVista\u003c\/strong\u003e software suite to facilitate streamlined configuration and event analysis.\u003c\/p\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin 760-P1-G1-S1-HI-A20-R\u003c\/strong\u003e serves as a digital relay intended for the management and primary protection and control of distribution feeders. The device provides comprehensive protection functions for feeders and back-up protection for buses, transformers, and transmission lines. Equipped with accurate built-in metering functions, it measures current, voltage, sequence components, power, energy, and voltage. The relay possesses robust communication interfaces, utilizing multiple protocols such as ModBus RTU, DNP 3.0 Level 2, and ModBus RTU TCP\/IP over an optional 10Mbps Ethernet port. It is suitable for applications in solidly grounded, high-impedance grounded, or resonant (Peterson Coil) grounded distribution systems. The architecture allows complete asset monitoring, system simulation, and advanced fault localization to enhance grid stability and equipment management.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete protection functions for feeders and back-up protection for bus, transformers, and transmission lines.\u003c\/li\u003e\n\u003cli\u003eDraw-out construction minimizes replacement time and maintenance efforts.\u003c\/li\u003e\n\u003cli\u003eAccurate built-in metering functions eliminating the need for auxiliary metering devices.\u003c\/li\u003e\n\u003cli\u003eComprehensive equipment management including a trip counter, trip coil monitoring, and breaker contact wear calculations.\u003c\/li\u003e\n\u003cli\u003eFlash memory for convenient product field upgrades.\u003c\/li\u003e\n\u003cli\u003eIRIG-B time synchronization input for accurate event stamping.\u003c\/li\u003e\n\u003cli\u003eAdvanced oscillography and data logger supporting up to 256 power frequency cycles of waveform data.\u003c\/li\u003e\n\u003cli\u003ePowerful built-in simulation features for verifying relay functionality against pre-fault, fault, and post-fault conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary protection and control for distribution feeders on solidly grounded, high impedance grounded, or resonant (Peterson Coil) grounded systems.\u003c\/li\u003e\n\u003cli\u003eBus blocking and interlocking schemes.\u003c\/li\u003e\n\u003cli\u003eHigh-speed fault detection for arc flash mitigation.\u003c\/li\u003e\n\u003cli\u003eThrow over schemes (bus transfer scheme applications on loss-of-source).\u003c\/li\u003e\n\u003cli\u003eLoad shedding schemes based on voltage and frequency elements.\u003c\/li\u003e\n\u003cli\u003eBack-up protection for transmission lines, feeders, and transformers.\u003c\/li\u003e\n\u003cli\u003eDistributed Generation (DG) interconnect protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrdering Code Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e760\u003c\/td\u003e\n\u003ctd\u003eFeeder Protection System with 4 Shot Recloser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase Current Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eP1\u003c\/td\u003e\n\u003ctd\u003e1 A phase current inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Current Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG1\u003c\/td\u003e\n\u003ctd\u003e1 A zero sequence current inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitive Ground Current Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS1\u003c\/td\u003e\n\u003ctd\u003e1 A sensitive ground current input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI\u003c\/td\u003e\n\u003ctd\u003e88-300 VDC, 70-265 VAC @48-62 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA20\u003c\/td\u003e\n\u003ctd\u003eEight 4-20 mA analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaker Status LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003ctd\u003eRed breaker closed LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Vernova \/ Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase Current Input Burden\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 0.2 VA at 1 or 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase Current Conversion Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 to 20 x CT (fundamental frequency only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Current Input Burden\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 0.2 VA at 1 or 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitive Ground Current Input Conversion Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.005 to 1.000 x CT (fundamental frequency only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus and Line Voltage Input Relay Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 V to 240 V phase-neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus and Line Voltage Input Max Continuous\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e273 V phase-neutral (full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic Inputs (Dry Contacts)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 maximum ON resistance (32 VDC @ 2 mA provided by relay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic Inputs (Wet Contacts)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 to 300 VDC @ 2.0 mA (external DC voltage only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Input Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-1 mA, 0-5 mA, 0-10 mA, 0-20 mA, or 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Input Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e375 ohm +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSolid State Trip Make and Carry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A @ 250 VDC for 500 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Relay Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 TRIP: Form A; 2 CLOSE: Form A; 3-7 AUXILIARY: Form C; 8 SELF-TEST WARNING: Form C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Relay Contact Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSilver alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHI Range Control Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC = 88 to 300 V; AC = 70 to 265 V @48-62Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 VA nominal, 35 VA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Loss Hold-up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Shipping Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating up to 95% (non condensing) @ 550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (front), IP20 (back)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eG7 \/ H7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase A Current Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eG8 \/ H8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase B Current Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eG9 \/ H9\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase C Current Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eG3 \/ H3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGround Current Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eG10 \/ H10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral Current Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eG5 \/ H5 \/ G6 \/ H6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Voltage Inputs (VA, VB, VC, VCOM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eG4 \/ H4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSync Voltage Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eH11 \/ H12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl Power Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eG11 \/ G12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFilter Ground \/ Chassis Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE1 \/ F1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid State Trip Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE2 \/ F2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput Relay 1 (TRIP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE3 \/ F3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput Relay 2 (CLOSE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE12 \/ F12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-Test Warning Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Panel Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232 Local Programming Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRear Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS485\/RS422 Ports (COM 1 \/ COM 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure reliable connection of the chassis ground to the substation safety ground grid via terminals G11\/G12.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Instrument and communication cable shields must be grounded at the PLC\/computer end only to avoid ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The device utilizes a draw-out construction designed for panel cutout installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Current transformer (CT) secondary inputs must be routed through automatic shorting terminals to ensure safety during maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePasscode Protection:\u003c\/strong\u003e Configure the optional software passcode to prevent unauthorized setpoint changes from the front panel or communication ports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus:\u003c\/strong\u003e UL508, UL1058, C22.2 No 14\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e EN60255-5, EN50263\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eType Tests Compliance:\u003c\/strong\u003e EN60255-5, IEC 61000-4-18, IEC 60255-22-1, EN61000-4-2, IEC 60255-22-2, EN61000-4-3, IEC 60255-22-3, EN61000-4-4, IEC 60255-22-4, EN61000-4-5, IEC 60255-22-5, EN61000-4-6, IEC 60255-22-6, CISPR11, CISPR22, IEC 60255-25, IEC 60255-21-1, IEC 60255-21-2, IEC 60255-21-3, IEC 61000-4-8, IEC 61000-4-9, IEC 61000-4-11, IEC 60529, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-30, IEEE\/ANSI C37.90.1, IEEE\/ANSI C37.90.2, IEEE\/ANSI C37.90.3, UL508, UL C22.2-14, UL1053\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695409754475,"sku":"760-P1-G1-S1-HI-A20-R","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ge-multilin-760-p1-g1-s1-hi-a20-r-multilin-feeder-management-relay-bsyp2l5hz2n_29cea042-aed5-4182-9697-465479060a99.jpg?v=1766135016","url":"https:\/\/www.plcprotech.com\/products\/ge-multilin-760-p1-g1-s1-hi-a20-r-multilin-feeder-management-relay","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}