{"product_id":"ge-multilin-ur-6av-universal-relay-series-digital-i-o-module","title":"GE Multilin UR-6AV Universal Relay Series Digital I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eUR-6AV (UR6AV)\u003c\/strong\u003e is an expansion \u003cstrong\u003eDigital I\/O Module\u003c\/strong\u003e engineered for General Electric's \u003cstrong\u003eUniversal Relay (UR)\u003c\/strong\u003e series protection platforms. This hardware card functions as a localized signal concentrator, providing the necessary contact inputs and outputs to bridge communication between the relay host and peripheral substation equipment. The module architecture is characterized by the \"6A\" order designation, which traditionally provides a specific combination of discrete input and output channels tailored for high-speed interlocking, signaling, and remote telemetry control loops.\u003c\/p\u003e\n\u003cp\u003eThe \"V\" configuration within the \u003cstrong\u003eUR-6AV (UR6AV)\u003c\/strong\u003e model structure designates its mechanical optimization for vertically mounted UR chassis systems. These units are specifically designed for space-restricted industrial switchgear and small-footprint control cabinets. Operating via the internal system backplane, the module enables field signals to be mapped directly into the host relay's internal logic engine using the \u003cstrong\u003eEnerVista\u003c\/strong\u003e configuration software utility. This setup eliminates comprehensive, traditional point-to-point secondary hardwiring while preserving electrical isolation against ambient transients.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVertical Form Factor Design\u003c\/strong\u003e: Built with a specialized mechanical layout tailored exclusively for space-saving vertical mount Universal Relay enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete I\/O Concentration\u003c\/strong\u003e: Integrates a dedicated combination of contact inputs and outputs onto a single plug-in board to scale relay telemetry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexLogic Subsystem Integration\u003c\/strong\u003e: Fully maps physical input statuses and output command states into the internal relay logic sequence for custom automation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardwired Layout Reduction\u003c\/strong\u003e: Decreases physical panel auxiliary wiring complexity by converting field signals directly into internal backplane digital data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubstation Hardened Architecture\u003c\/strong\u003e: Constructed with industrial-grade physical components designed to suppress electromagnetic interference (EMI) and power surges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed status monitoring and interlocking logic in vertical-mount protection systems\u003c\/li\u003e\n\u003cli\u003eHigh-speed auxiliary signaling loops for distribution switchgear control panels\u003c\/li\u003e\n\u003cli\u003eAutomated industrial substation telemetry expansion\u003c\/li\u003e\n\u003cli\u003eInput\/output slot scaling for GE Multilin \u003cstrong\u003eUR Series\u003c\/strong\u003e platforms (e.g., F60, B30, L90, T60)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Multilin (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUR-6AV (UR6AV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Input\/Output Module (Digital I\/O Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Mounting Alignment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnerVista UR Setup Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature scope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 Celsius to +70 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature scope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 Celsius to +85 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eEnclosure Layout and Mechanical Alignment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the physical orientation of the target enclosure card cage before installing the module. The \u003cstrong\u003eUR-6AV (UR6AV)\u003c\/strong\u003e features structural keying and physical specifications intended solely for vertical slot configurations.\u003c\/li\u003e\n\u003cli\u003eDo not attempt insertion into standard horizontal rack frameworks, as this can result in mechanical binding or severe backplane pin misalignment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePre-Installation Power Isolation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompletely switch off and isolate the primary auxiliary AC\/DC control voltage lines entering the primary relay power supply module.\u003c\/li\u003e\n\u003cli\u003eDisconnect or trip external breaker control loops wired to the card's target terminal blocks to prevent accidental breaker actuation or severe shock risks during maintenance.\u003c\/li\u003e\n\u003cli\u003eSecurely wear an earth-grounded electrostatic discharge (ESD) wrist strap throughout the card replacement process to safeguard internal CMOS microprocessors from static damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCard Insertion Mechanics\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSlide the side edges of the circuit card squarely into the molded plastic track guides of the vacant target slot.\u003c\/li\u003e\n\u003cli\u003ePush the module smoothly into the backplane channel until the outer aluminum faceplate sits perfectly flush with the adjacent modular assemblies.\u003c\/li\u003e\n\u003cli\u003eApply firm, centered manual pressure to guarantee the multi-pin rear terminal blocks mate completely with the internal backplane receptor.\u003c\/li\u003e\n\u003cli\u003eSecurely tighten both the upper and lower faceplate retention screws to lock mechanical stability and finalize the primary chassis earth ground pathway.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific configuration utility is utilized to set up the I\/O channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module paths are configured via General Electric's standard EnerVista UR Setup Software. This utility allows commissioning engineers to map discrete field input points to internal logic state operands and bind protection variables to the physical output contacts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this vertical I\/O card be mixed with older generation modules inside the relay?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, but when upgrading components within the Universal Relay framework, you must check the main hardware ordering rules. While I\/O modules are generally cross-compatible across firmware eras, matching structural variants (such as keeping all expansion modules within the vertical format inside a vertical chassis) is required to ensure mechanical compliance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the consequences of seating the card while the backplane is actively energized?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHot-swapping is not supported for this hardware block. Seating or extracting the card module while the internal backplane distribution rails are live can generate electrical terminal arcing, trigger permanent data register corruption, or place the host protective CPU into a critical system halt state.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695419715947,"sku":"UR-6AV","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ur6av-multilin-i-o-8-digital-inputs-module-31xnx4kp0e1_3063c3cc-fcc5-488a-ae8d-b261be6173ca.jpg?v=1766135361","url":"https:\/\/www.plcprotech.com\/products\/ge-multilin-ur-6av-universal-relay-series-digital-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}