{"product_id":"ge-multilin-ur-rhh-universal-relay-power-supply-module","title":"GE Multilin UR-RHH Universal Relay Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin UR-RHH\u003c\/strong\u003e is a power supply module designed for direct installation within Universal Relays (UR) series protection and control systems. It converts input station power to supply internal processing logic and feed field dry contact inputs. Featuring built-in diagnostic and health-testing logic, the module continually evaluates internal hardware integrity and de-energizes automatically in the event of a critical component failure while reporting operational status through faceplate status LEDs.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with GE Multilin Universal Relay (UR) chassis systems\u003c\/li\u003e\n\u003cli\u003eHigh Range (HI) nominal operational capability supporting 125 to 250 V (DC and AC)\u003c\/li\u003e\n\u003cli\u003eContinuous auto-diagnostic self-testing with major and minor device integrity checks\u003c\/li\u003e\n\u003cli\u003eAutomatic de-energization execution during critical failure detection\u003c\/li\u003e\n\u003cli\u003eFaceplate LED status reporting including continuous on, cycling, and off states\u003c\/li\u003e\n\u003cli\u003eBlack matte finish for environmental protection and aesthetic integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary and secondary power distribution in GE Multilin UR protection relay racks\u003c\/li\u003e\n\u003cli\u003eUtility substations requiring reliable internal processing and contact input power\u003c\/li\u003e\n\u003cli\u003eIndustrial power systems utilizing GE EnerVista UR software management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 103.958%;\" height=\"369\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 51.6878%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 47.8903%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.6878%;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"width: 47.8903%;\"\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.6878%;\"\u003eManufacturing Location\u003c\/td\u003e\n\u003ctd style=\"width: 47.8903%;\"\u003eMarkham, Ontario, Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.6878%;\"\u003eNominal Input Voltage (High Range - HI)\u003c\/td\u003e\n\u003ctd style=\"width: 47.8903%;\"\u003e125 to 250 VDC \/ 100 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.6878%;\"\u003ePower Output \/ Consumption\u003c\/td\u003e\n\u003ctd style=\"width: 47.8903%;\"\u003e35 W \/ 35 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.6878%;\"\u003eInternal Fuse Rating\u003c\/td\u003e\n\u003ctd style=\"width: 47.8903%;\"\u003e4 A \/ 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.6878%;\"\u003eIsolation Voltage Level\u003c\/td\u003e\n\u003ctd style=\"width: 47.8903%;\"\u003e2000 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.6878%;\"\u003eDiagnostic Status Indicators\u003c\/td\u003e\n\u003ctd style=\"width: 47.8903%;\"\u003eContinuous ON, ON\/OFF Cycling, OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.6878%;\"\u003eElectrolytic Capacitors\u003c\/td\u003e\n\u003ctd style=\"width: 47.8903%;\"\u003e27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.6878%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 47.8903%;\"\u003eapprox. 2 lb 2 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.6878%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 47.8903%;\"\u003eapprox. 6.5 in L x 6.5 in W x 1.75 in H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 51.6878%;\"\u003eSoftware\u003c\/td\u003e\n\u003ctd style=\"width: 47.8903%;\"\u003eEnerVista UR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure input power lines are de-energized before inserting or removing the module from the UR rack chassis.\u003c\/li\u003e\n\u003cli\u003eVerify correct ground continuity to the chassis frame to mitigate electromagnetic interference and line transients.\u003c\/li\u003e\n\u003cli\u003eEnsure proper ventilation spacing around the UR enclosure to support passive convective heat dissipation.\u003c\/li\u003e\n\u003cli\u003eObserve internal fuse rating limits (4 A \/ 250 V) when servicing or performing maintenance procedures.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53614189707627,"sku":"UR-RHH","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/UR-RHH_1.jpg?v=1785143192","url":"https:\/\/www.plcprotech.com\/products\/ge-multilin-ur-rhh-universal-relay-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}