{"product_id":"ge-multilin-ur6dv-ur-6dv-ur-series-digital-i-o-module","title":"GE Multilin UR6DV (UR-6DV) UR Series Digital I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eUR6DV (UR-6DV)\u003c\/strong\u003e is a high-density digital input\/output module engineered for the General Electric \u003cstrong\u003eUniversal Relay (UR) Series\u003c\/strong\u003e platform. This module serves as a critical hardware interface between external field switchgear devices and the internal processing environment of protection, control, and monitoring relays. It provides simultaneous discrete signal acquisition and heavy-duty control execution capabilities, facilitating high-speed communication over the internal backplane bus. Designed for deployment in utility substations, power generation facilities, and critical heavy industrial networks, the \u003cstrong\u003eUR6DV\u003c\/strong\u003e ensures reliable monitoring of breaker status auxiliary contacts, disconnect switches, and external lockout systems while providing low-latency control outputs for protective tripping circuits. It functions seamlessly within modular UR chassis configurations, maintaining full compatibility with core processor modules and EnerVista orchestration software.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-density contact configuration optimizing chassis slot utilization\u003c\/li\u003e\n\u003cli\u003eHardware and software filtering on inputs to eliminate false triggers from induced AC noise or DC battery ground faults\u003c\/li\u003e\n\u003cli\u003eHeavy-duty output relay contacts designed to handle inductive trip coil currents\u003c\/li\u003e\n\u003cli\u003eHigh-speed physical contact closure execution minimizing protection loop latency\u003c\/li\u003e\n\u003cli\u003ePlug-in form factor allowing secure mounting inside standard 19-inch UR rack enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUtility substation automation and distribution system control\u003c\/li\u003e\n\u003cli\u003eCircuit breaker status monitoring and automatic trip\/close control loops\u003c\/li\u003e\n\u003cli\u003eDisconnect switch and grounding switch position indication\u003c\/li\u003e\n\u003cli\u003ePower generation plant protection systems (such as G60 or Generator Management setups)\u003c\/li\u003e\n\u003cli\u003eIndustrial microgrid power management and load shedding systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input \/ Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Series\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Threshold Options\u003c\/td\u003e\n\u003ctd\u003eConfigurable for 24 VDC, 48 VDC, 125 VDC, or 250 VDC utility control circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Immunity Standard\u003c\/td\u003e\n\u003ctd\u003eCompliant with IEEE C37.90.1 and IEC 60255\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Dimensions\u003c\/td\u003e\n\u003ctd\u003eStandard UR Series rear slot plug-in card dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Isolation:\u003c\/strong\u003e De-energize the main UR relay chassis and completely isolate all connected external DC battery control voltage sources before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Alignment:\u003c\/strong\u003e Slide the module precisely along the plastic guide rails of the designated rear chassis slot to prevent pins on the backplane connector from bending.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block Fastening:\u003c\/strong\u003e Secure the rear terminal block using the integral captive screws to guarantee structural stability under high-vibration conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Ensure the overall chassis ground terminal is connected to the primary station ground bus via a low-impedance copper strap to mitigate EMI and RFI anomalies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Separate discrete control and trip circuit wiring from low-voltage communication or analog signaling paths within the enclosure panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the UR6DV module inside a Universal Relay chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module acts as the physical link between external discrete field components and the internal microprocessor logic, reading high-voltage status indications and executing hardware trip or close commands.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support hot-swapping while the relay is active?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, complete isolation of the chassis power supply and external field wetting voltages is required prior to removal to avoid unintentional circuit breaker tripping or backplane communication damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the input circuitry manage high levels of electrical noise common in substations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe digital inputs employ selectable hardware thresholds combined with programmable software debounce timers to filter out high-frequency transients, inductive coupling, and battery ground faults.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre the contact outputs capable of directly breaking inductive circuit breaker trip currents?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the internal relays are designed with high inductive current ratings and arc suppression properties to reliably control standard utility switchgear trip coils.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695422501227,"sku":"UR-6DV","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ur6dv-digital-i-o-module-nwus5gdfrzv_99f527d6-8398-478a-9291-0b1fcbf40d0a.jpg?v=1766135471","url":"https:\/\/www.plcprotech.com\/products\/ge-multilin-ur6dv-ur-6dv-ur-series-digital-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}