{"product_id":"general-electric-ds200plibg2aca-phase-logic-interface-board","title":"General Electric DS200PLIBG2ACA Phase Logic Interface Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric DS200PLIBG2ACA is a Phase Logic Interface Board designed for use within the Mark V Speedtronic control system architecture. This specialized printed circuit board facilitates critical control functions in industrial turbine management applications, specifically interfacing with EX2000 digital regulator systems for brushless excitation and supporting both single-phase and three-phase configurations. As an essential component for legacy turbine control systems, it manages state transitions and provides reliable phase logic execution.\u003c\/p\u003e\n\u003cp\u003eEngineered for high-reliability environments, the board features robust surface-mount and through-hole components, including integrated circuits, resistors, capacitors, LEDs, diodes, and multiple vertical pin connectors. It incorporates factory-drilled, insulated mounting holes to ensure secure electrical isolation and mechanical stability when installed in standard control cabinet racks.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  Supports 3-phase and single-phase voltage source inputs for flexible turbine management.\n  Compatible with GE Mark V Speedtronic control systems and EX2000 digital regulator systems.\n  Equipped with factory-drilled, insulated mounting holes for secure cabinet installation.\n  Features robust onboard diagnostic LEDs for status indication and troubleshooting.\n  Designed with high-dielectric isolation to protect against transient industrial electrical noise.\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  Gas and steam turbine generator control and regulation.\n  Brushless excitation systems utilizing EX2000 regulators.\n  Legacy Mark V Speedtronic distributed control system (DCS) maintenance and retrofits.\n  Phase-angle detection and logic interfacing in heavy industrial power generation.\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eGeneral Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number\u003c\/td\u003e\n      \u003ctd\u003eDS200PLIBG2ACA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eMark V Speedtronic\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003ePhase Logic Interface Board\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e0 to 150 V AC (3-phase sources)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Range\u003c\/td\u003e\n      \u003ctd\u003e45 to 65 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Power Supply\u003c\/td\u003e\n      \u003ctd\u003e+5 V DC (internal backplane)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResponse Time\u003c\/td\u003e\n      \u003ctd\u003eUnder 2 cycles\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n      \u003ctd\u003ePlus or minus 1 percent full scale\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n      \u003ctd\u003e2500 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n  Multiple vertical pin connectors for internal rack and backplane communication.\n  Pluggable and onboard wiring terminals for primary phase voltage inputs.\n  Diagnostic LED indicators for visual operational status monitoring.\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  Ensure all rack power is completely de-energized before installing or removing the DS200PLIBG2ACA module.\n  Observe standard electrostatic discharge (ESD) precautions, including the use of a grounded wrist strap, when handling the circuit board.\n  Secure the module evenly using the insulated mounting holes to maintain proper chassis ground isolation.\n  Verify firmware and hardware revision compatibility with existing Mark V rack components prior to system startup.\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695410606443,"sku":"DS200PLIBG2ACA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ds200plibg2aca-phase-logic-interface-board-3k54yjsygoh_0e1f8955-15e2-4f15-907d-7ec63873ceea.jpg?v=1766135051","url":"https:\/\/www.plcprotech.com\/products\/general-electric-ds200plibg2aca-phase-logic-interface-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}