{"product_id":"general-electric-ds200tceag1bsf-mark-v-emergency-overspeed-board","title":"General Electric DS200TCEAG1BSF Mark V Emergency Overspeed Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDS200TCEAG1BSF\u003c\/strong\u003e is a printed circuit board developed by General Electric for the Mark V Turbine Control System Series. Functioning as an \u003cstrong\u003eEmergency Overspeed Board\u003c\/strong\u003e (abbreviated as TCEA), this Group 1 module is integrated into automated drive assemblies for wind, steam, or gas turbine control applications. The \u003cstrong\u003eDS200TCEAG1BSF\u003c\/strong\u003e features a normal assembly type with specialized functional and artwork revisions, building upon the baseline architecture of the parent DS200TCEAG1 board layout.\u003c\/p\u003e\n\u003cp\u003eThe primary function of this board is to process turbine overspeed limits and manage flame detection trip signals, initiating drive shutdowns when safety boundaries are breached. Positioned securely within the system \u0026lt; P \u0026gt; core, it coordinates diagnostic routines via specialized internal hardware structures, using Speedtronic control technology to interface with auxiliary control boards across the drive network.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmploys specialized integrated loops including TCEA Flame Detection, TCEA Turbine Overspeed, and TCEA Automatic Synchronizing circuits.\u003c\/li\u003e\n\u003cli\u003eFeatures an onboard 80196 microprocessor designed for high-reliability local signal processing and trip execution.\u003c\/li\u003e\n\u003cli\u003eAccommodates multiple programmable read-only memory (PROM) modules for firmware management.\u003c\/li\u003e\n\u003cli\u003eOutfitted with a standard protective layer using a normal style PCB coating to insulate circuit traces.\u003c\/li\u003e\n\u003cli\u003eIncorporates 30 manual Berg jumpers for precise location programming and functional hardware tracking.\u003c\/li\u003e\n\u003cli\u003eUtilizes the Mark V IO Configuration Editor for software setup and system parameter alignment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGas, steam, and wind turbine automated drive systems.\u003c\/li\u003e\n\u003cli\u003eEmergency trip and turbine overspeed monitoring infrastructure.\u003c\/li\u003e\n\u003cli\u003eTriple Modular Redundant (TMR) safety and diagnostic control loops.\u003c\/li\u003e\n\u003cli\u003eIndustrial flame detection and emergency signal isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMark V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS200TCEAG1BSF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmergency Over Speed Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Acronym\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTCEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssembly Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormal Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRevision Quantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMark V Series Grouping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMicroprocessor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntel 80196\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJumpers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 Berg jumpers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePair of bayonet connectors, multi-pin block connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; P \u0026gt; Core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoftware Management\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIO Configuration Editor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJ7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePD Core Power Distribution Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTCEB Board Signal Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTCTG Board Trip Signal Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTCEB Board Flame Detection Signal Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJX1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDaisy Chained IONET Connector 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJX2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDaisy Chained IONET Connector 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoard Orientation \u0026amp; Support:\u003c\/strong\u003e When inserting or removing cables via the male bayonet connectors, hold the connector with one hand and secure the board frame firmly with the other hand to prevent bending or mechanical stress on the board substrate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation Programming:\u003c\/strong\u003e Configure the 30 onboard Berg jumpers to program the card for its precise tracking location in the \u0026lt; P \u0026gt; core. If the module is relocated within the panel, these jumpers must be reset to match the new slot coordinates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Configuration:\u003c\/strong\u003e Complete system deployment and interface configuration via the standard Mark V IO Configuration Editor tool.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit Protection:\u003c\/strong\u003e Ensure all 3 onboard fuses are present and correctly matched to the designated circuit specifications before restoring power to the distribution network via the J7 connector.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695420961131,"sku":"DS200TCEAG1BSF","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ds200tceag1bsf-emergency-overspeed-board-wuoz2epi2at_e6fa553c-a4a5-4bc1-b784-ea6ca09b4c86.jpg?v=1766135412","url":"https:\/\/www.plcprotech.com\/products\/general-electric-ds200tceag1bsf-mark-v-emergency-overspeed-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}