{"product_id":"general-electric-ds200tceag1btf-mark-v-emergency-overspeed-board","title":"General Electric DS200TCEAG1BTF Mark V Emergency Overspeed Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDS200TCEAG1BTF\u003c\/strong\u003e is a printed circuit board (PCB) developed by General Electric for the Mark V Series turbine control systems. Functioning as an \u003cstrong\u003eEmergency Overspeed Board\u003c\/strong\u003e, this specific revision incorporates key hardware enhancements over the parent DS200TCEAG1 board, integrating three total functional and artwork modifications designated by the BTF suffix.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eDS200TCEAG1BTF\u003c\/strong\u003e leverages Speedtronic control technology to interface with the automated drive assembly of the turbine. Its central application involves executing safety and control routines via specialized hardware loops, processing critical protective data including turbine overspeed limits and flame detection signals. Situated within the designated \u0026lt; P \u0026gt; core of the control drive system, it provides vital control and emergency shutdown functionalities for industrial turbine applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrates specialized internal circuitry including TCEA Flame Detection, TCEA Turbine Overspeed, and TCEA Automatic Synchronizing loops.\u003c\/li\u003e\n\u003cli\u003eUses an onboard 80196 microprocessor to execute local process automation and emergency signal evaluation.\u003c\/li\u003e\n\u003cli\u003eContains sockets to accommodate multiple programmable erasable read-only memory (EPROM) modules for firmware application.\u003c\/li\u003e\n\u003cli\u003eFeatures dedicated hardware points including 30 manual jumpers, 3 protection fuses, and 2 bayonet connectors.\u003c\/li\u003e\n\u003cli\u003eEmploys specialized interface routing through active board connectors, completely eliminating unused vestigial structures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial gas and steam turbine overspeed protection systems.\u003c\/li\u003e\n\u003cli\u003eMark V turbine control drive automation and signaling.\u003c\/li\u003e\n\u003cli\u003eTriple Modular Redundant (TMR) turbine control architectures.\u003c\/li\u003e\n\u003cli\u003eFlame detection monitoring and emergency trip execution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMark V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS200TCEAG1BTF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmergency Over Speed Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Abbreviation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTCEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePCB Coating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormal Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1st Functional Revision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2nd Functional Revision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArtwork Revision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMicroprocessor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntel 80196\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 fuses (FU1, FU2, FU3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJumpers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 jumpers (Berg type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Bayonet connectors, multi-pin signal connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; P \u0026gt; Core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJ7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePD Core TCEA Board Power Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTCEB Board P1 Core Signal Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTCTG Board Trip Signals Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTCEB Board Flame Detection Signal Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJX1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDaisy Chained IONET TCQC Board Connector 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJX2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDaisy Chained IONET TCQC Board Connector 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation \u0026amp; Configuration:\u003c\/strong\u003e Mount the board inside the designated \u0026lt; P \u0026gt; core slot. Use the on-board Berg jumpers to program the exact physical and functional location within the turbine control drive housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Replacement:\u003c\/strong\u003e When replacing any of the three hardware fuses (FU1, FU2, FU3), use only identical replacement components with matching current and voltage ratings to protect circuit trace paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Connect the dedicated interface lines to the J7, JK, JL, JW, JX1, and JX2 ports. Ensure proper seating of the bayonet and multi-pin connectors to avoid signal corruption across the IONET and TCTG paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Precautions:\u003c\/strong\u003e Handle the board by the edges or mounting frame to avoid static damage to the 80196 microprocessor and EPROM modules.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695410934123,"sku":"DS200TCEAG1B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ds200tceag1btf-emergency-overspeed-board-aw45fvk2c1z_7623bb15-eb34-497a-9c2f-ba753310fe7f.jpg?v=1766135062","url":"https:\/\/www.plcprotech.com\/products\/general-electric-ds200tceag1btf-mark-v-emergency-overspeed-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}