{"product_id":"general-electric-ds3800hiod1h1g-digtal-i-o-board","title":"GE DS3800HIOD1H1G Mark IV Digital I\/O Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDS3800HIOD1H1G\u003c\/strong\u003e functions as a discrete digital input\/output routing interface component within the \u003cstrong\u003eMark IV\u003c\/strong\u003e Speedtronic industrial management sequence. This line driver circuit board processes binary automation signals to govern gate controls and logic networks connected to heavy-duty gas turbine systems.\u003c\/p\u003e\n\u003cp\u003eThe hardware implementation of the \u003cstrong\u003eDS3800HIOD1H1G\u003c\/strong\u003e incorporates high-density front-accessible line interfaces to establish robust plant interconnects. On one side of the layout, a built-in modular plug links the board channels directly into the system backplane, while the opposite side features integrated mechanical retention levers to facilitate clean extraction and secure locking into the drive slot housing. Positioned squarely between the dual extraction levers are two 10-pin interface terminals and one high-density 40-pin connector layout, allowing engineers to service discrete field wiring from the front faceplate area. Additionally, six adjustable physical onboard jumpers are integrated into the surface matrix to configure custom hardware line tracking. The component traces are highly susceptible to electrostatic accumulation, requiring careful ESD grounding controls during field retrofitting.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Front Connectivity:\u003c\/strong\u003e Integrates 2 ten-pin connection headers and 1 forty-pin primary connector placed for clean access between retention levers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnboard Signal Customization:\u003c\/strong\u003e Populated with 6 operational hardware jumpers to support manual logic path selection across the line driver framework.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLever-Lock Insertion Interface:\u003c\/strong\u003e Features factory-installed mechanical retention clips on the front edge to ensure positive board locking inside tight slots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Gas Turbine Processing:\u003c\/strong\u003e Engineered to meet the precise timing tolerances required by legacy Speedtronic gas turbine automation panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeedtronic Signal Line Driving:\u003c\/strong\u003e Drives digital command and feedback signals across distributed gas turbine control systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete I\/O Multiplexing:\u003c\/strong\u003e Manages auxiliary control paths and binary inputs coming from peripheral turbine infrastructure devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation Line Protection:\u003c\/strong\u003e Serves as an isolated signal interface to prevent electrical cross-talk across backplane communication buses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS3800HIOD1H1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMark IV Speedtronic Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O Board \/ Line Driver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegrated Jumper Config\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 Hardware Jumpers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Interface Blocks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo 10-pin connectors, One 40-pin connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRear Mounting Link\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Modular Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESD Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensitive to static electricity build-up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Matrix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eAccessibility\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModular Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRear Backplane Plug\u003c\/td\u003e\n\u003ctd\u003eSlot Interior\u003c\/td\u003e\n\u003ctd\u003eDirect internal system power and data bus linking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10-Pin Connectors (x2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMale Pin Headers\u003c\/td\u003e\n\u003ctd\u003eFront Panel Panel\u003c\/td\u003e\n\u003ctd\u003eAuxiliary digital signal inputs and output loop tracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e40-Pin Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-Density Header\u003c\/td\u003e\n\u003ctd\u003eFront Panel Panel\u003c\/td\u003e\n\u003ctd\u003eMain field instrumentation wiring trunk interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete System Depower:\u003c\/strong\u003e De-energize, lock out, and tag out all primary and auxiliary power distribution grids feeding the control chassis before touching the slot space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatic Discharge Containment:\u003c\/strong\u003e Keep the board inside its sealed static protection shipping container until active deployment. Field engineers must wear an approved, grounded ESD anti-static wrist strap clipped to a verified metal structure throughout handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCard Slot Insertion:\u003c\/strong\u003e Align the board edges inside the drive track, pushing steadily until the rear modular connector docks into the receiver block. Do not force alignment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention Clip Securing:\u003c\/strong\u003e Press the front mechanical retention levers completely down to lock the module face securely into the rack frame, preventing terminal drift from industrial turbine vibration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695420076395,"sku":"DS3800HIOD1H1G","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ds3800hiod1h1g-digtal-i-o-board-xzdxoinoadi_ceaf2615-af3b-4ed4-8fd8-0b4816d5dd0b.jpg?v=1766135373","url":"https:\/\/www.plcprotech.com\/products\/general-electric-ds3800hiod1h1g-digtal-i-o-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}