{"product_id":"general-electric-ic200mdl330-versamax-discrete-isolated-output-module","title":"General Electric IC200MDL330 VersaMax Discrete Isolated Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC200MDL330 is a 16-point discrete isolated output module designed for use within the VersaMax I\/O system family. This high-density output module provides reliable switching capabilities for industrial automation applications, requiring an external 120VAC power supply to energize connected loads. Intelligent processing and communication functions are handled directly by the system CPU or Network Interface Unit (NIU).\u003c\/p\u003e\n\u003cp\u003eEngineered for safety and operational reliability, the IC200MDL330 features robust optical isolation between field outputs and internal logic, as well as group-to-group and point-to-point isolation barriers. Built-in LED indicators provide clear visual feedback, displaying individual point ON\/OFF states alongside a dedicated backplane power status indicator.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e16 isolated discrete output channels\u003c\/li\u003e\n  \u003cli\u003eExternal power supply rating of 85 to 132VAC (47 to 63Hz) at 120VAC nominal\u003c\/li\u003e\n  \u003cli\u003eRobust isolation: 250VAC continuous and 1500VAC for 1 minute (user input to logic, group-to-group, and point-to-point)\u003c\/li\u003e\n  \u003cli\u003eIndividual green logic-driven LED indicators for each output point\u003c\/li\u003e\n  \u003cli\u003eDedicated OK LED for backplane power status monitoring\u003c\/li\u003e\n  \u003cli\u003eBuilt-in snubber circuits and MOVs for output protection against transient overvoltages\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting compatibility within the VersaMax modular architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDiscrete actuator control (solenoids, contactors, and indicator lamps)\u003c\/li\u003e\n  \u003cli\u003eAC motor starter interfacing\u003c\/li\u003e\n  \u003cli\u003eIndustrial manufacturing assembly lines\u003c\/li\u003e\n  \u003cli\u003eProcess control and packaging machinery\u003c\/li\u003e\n  \u003cli\u003eDistributed I\/O drops in hazardous location environments (Class I, Division 2)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eGeneral Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003eIC200MDL330\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Family\u003c\/td\u003e\n      \u003ctd\u003eVersaMax I\/O\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n      \u003ctd\u003e16 isolated outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e85 to 132 VAC (47 to 63Hz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Current per Point\u003c\/td\u003e\n      \u003ctd\u003e10mA minimum to 0.5A maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInrush Current\u003c\/td\u003e\n      \u003ctd\u003e5.0A maximum for one cycle (20ms)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage Drop\u003c\/td\u003e\n      \u003ctd\u003e2.0V maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Leakage Current\u003c\/td\u003e\n      \u003ctd\u003eLess than 2mA at 132VAC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResponse Time\u003c\/td\u003e\n      \u003ctd\u003eLess than 1\/2 cycle maximum (on and off)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBackplane Current Consumption\u003c\/td\u003e\n      \u003ctd\u003e140mA maximum (5V output)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIsolation Rating\u003c\/td\u003e\n      \u003ctd\u003e250VAC continuous; 1500VAC for 1 min (optical logic, group-to-group, point-to-point)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule ID Code\u003c\/td\u003e\n      \u003ctd\u003e88408840\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eField wiring terminals accommodate two-row or three-row terminal carriers\u003c\/li\u003e\n  \u003cli\u003eTerminals A1 through A16 handle Outputs 1 through 8 and their respective returns\u003c\/li\u003e\n  \u003cli\u003eTerminals B1 through B16 handle Outputs 9 through 16 and their respective returns\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure all external power is disconnected before installing, wiring, or replacing modules in hazardous or non-hazardous locations.\u003c\/li\u003e\n  \u003cli\u003eWhen connecting output channels to inductive loads, use external suppression circuits (such as MOV or RC networks) to prolong relay and switch contact life.\u003c\/li\u003e\n  \u003cli\u003eObserve thermal derating guidelines regarding ambient temperature and the number of points active simultaneously to prevent module overheating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770194059627,"sku":"IC200MDL330","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ic200mdl330_1200x1200_4992d2c5-b388-417c-9ebc-afd90552fc16.jpg?v=1787738195","url":"https:\/\/www.plcprotech.com\/products\/general-electric-ic200mdl330-versamax-discrete-isolated-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}