{"product_id":"general-electric-ic610mdl179-series-one-ac-output-module","title":"General Electric IC610MDL179 Series One AC Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC610MDL179 is a Series One 115\/230V AC output module featuring 8 discrete output circuits designed to control user-supplied ON\/OFF loads. Engineered for reliable industrial automation performance, this module efficiently manages inductive and resistive loads such as relay coils, motor starters up to size No. 3, solenoid valves, and visual indicator lights. The 8 individual output points are segregated into 2 isolated groups of 4 circuits each, allowing separate power sources to be applied to each group depending on your panel architecture requirements.\u003c\/p\u003e\n\u003cp\u003eEquipped with a removable terminal board for streamlined wiring and maintenance, the IC610MDL179 incorporates solid-state switching with individual logic-side circuit indicators to display operational status. Each group of 4 circuits is internally protected by a soldered 5-amp fuse. The module integrates seamlessly into legacy GE Series One PLC racks, delivering precise response times and robust isolation for discrete control applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8 discrete AC output circuits divided into 2 isolated groups of 4 channels\u003c\/li\u003e\n  \u003cli\u003eOperating voltage range of 80 to 264V AC at 47 to 63Hz\u003c\/li\u003e\n  \u003cli\u003eMaximum continuous current rating of 1A per point\u003c\/li\u003e\n  \u003cli\u003eLogic-side circuit indicators for real-time status monitoring\u003c\/li\u003e\n  \u003cli\u003eBuilt-in protection featuring dual 5A internal soldered fuses (one per 4-circuit group)\u003c\/li\u003e\n  \u003cli\u003eRemovable terminal board design for fast installation and easy field wiring replacement\u003c\/li\u003e\n  \u003cli\u003eSolid-state switching providing rapid 1ms OFF-to-ON and 9ms ON-to-OFF response times\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eControlling industrial motor starters up to size No. 3\u003c\/li\u003e\n  \u003cli\u003eSwitching AC relay and contactor coils\u003c\/li\u003e\n  \u003cli\u003eOperating pneumatic and hydraulic solenoid valves\u003c\/li\u003e\n  \u003cli\u003eDriving panel status indicator lights and horns\u003c\/li\u003e\n  \u003cli\u003eLegacy GE Series One automation system upgrades and maintenance replacements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eGeneral Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003eIC610MDL179\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eAC Output Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePlatform\u003c\/td\u003e\n      \u003ctd\u003eSeries One\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Points\u003c\/td\u003e\n      \u003ctd\u003e8 circuits (2 groups of 4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Voltage\u003c\/td\u003e\n      \u003ctd\u003e80 to 264V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAC Frequency\u003c\/td\u003e\n      \u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Current\u003c\/td\u003e\n      \u003ctd\u003e1A per point\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Leakage Current\u003c\/td\u003e\n      \u003ctd\u003e1.2 mA at 230V AC, 60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eON Voltage Drop\u003c\/td\u003e\n      \u003ctd\u003e1.5V at 1A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSmallest Recommended Load\u003c\/td\u003e\n      \u003ctd\u003e25 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n      \u003ctd\u003e10A for 17 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOFF to ON Response Time\u003c\/td\u003e\n      \u003ctd\u003e1 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eON to OFF Response Time\u003c\/td\u003e\n      \u003ctd\u003e9 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInternal Protection\u003c\/td\u003e\n      \u003ctd\u003e(2) 5A internal soldered fuses (one per 4-circuit group)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInternal Power Consumption\u003c\/td\u003e\n      \u003ctd\u003e12 mA for each ON circuit at 9V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnits of Load\u003c\/td\u003e\n      \u003ctd\u003e16 at 9V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCircuit Indicators\u003c\/td\u003e\n      \u003ctd\u003eLogic side LEDs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cp\u003eField wiring connects via the integrated removable terminal board on the front of the module. Terminals 0 through 3 correspond to the first group of 4 outputs, and terminals 4 through 7 correspond to the second group of 4 outputs. Hot connections for the AC power supply are tied together internally for each group, while user loads are wired in series between the module output terminals and the neutral return.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure all rack power is disconnected before installing or removing the module.\u003c\/li\u003e\n  \u003cli\u003eVerify that external user-supplied power sources feeding the load circuits are properly fused and rated within the 80 to 264V AC operating window.\u003c\/li\u003e\n  \u003cli\u003eEnsure the removable terminal board is securely seated and retention screws are tightened to maintain reliable electrical contact.\u003c\/li\u003e\n  \u003cli\u003eObserve derating guidelines when operating multiple circuits simultaneously at elevated ambient temperatures to prevent thermal overload.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770265428331,"sku":"IC610MDL179","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/IC610MDL179_1200x1200_ab15ea22-f7e8-4c43-8adb-072acf5421d0.jpg?v=1787739915","url":"https:\/\/www.plcprotech.com\/products\/general-electric-ic610mdl179-series-one-ac-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}