{"product_id":"general-electric-ic670mdl233-field-control-discrete-input-module","title":"General Electric IC670MDL233 Field Control Discrete Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC670MDL233 is an 8-point isolated discrete input module designed for the GE Field Control distributed I\/O architecture. This module provides reliable monitoring of 120VAC industrial input devices, converting alternating current field signals into digital data suitable for system processing. Operating within a 0 to 132VAC input range at 47 to 63 Hz, it incorporates internal resistor-capacitor networks and optoisolators to deliver robust noise filtering and complete electrical isolation between field circuits and system logic.\u003c\/p\u003e\n\u003cp\u003ePower for internal module operation is supplied directly via the backplane from a compatible Bus Interface Unit (BIU), drawing a maximum of 40 mA. External input devices require a separate 120VAC power source. Real-time status indication is provided by individual front-panel LEDs for each input point alongside a dedicated power (PWR) LED that confirms backplane power availability. The module communicates its 8 bits of discrete input data to the host or local processor through the system BIU.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides 8 isolated 120VAC discrete inputs for GE Field Control systems\u003c\/li\u003e\n  \u003cli\u003eWide input voltage range from 0 to 132VAC (47 to 63 Hz)\u003c\/li\u003e\n  \u003cli\u003eBuilt-in optoisolation offering 250VAC continuous and 1500VAC one-minute dielectric strength between user inputs and logic or frame ground\u003c\/li\u003e\n  \u003cli\u003eIndividual point status LEDs and a dedicated backplane power (PWR) indicator\u003c\/li\u003e\n  \u003cli\u003eLow internal power consumption, drawing a maximum of 40 mA from the Bus Interface Unit\u003c\/li\u003e\n  \u003cli\u003eConfigurable intelligent processing features including input defaults and fault reporting handled via the BIU\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDiscrete industrial automation and manufacturing lines\u003c\/li\u003e\n  \u003cli\u003eAC sensor and limit switch monitoring\u003c\/li\u003e\n  \u003cli\u003eProcess control and packaging machinery\u003c\/li\u003e\n  \u003cli\u003eDistributed I\/O architectures requiring isolated 120VAC signal acquisition\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eGeneral Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number \/ Exact Model\u003c\/td\u003e\n      \u003ctd\u003eIC670MDL233\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Family\u003c\/td\u003e\n      \u003ctd\u003eGE Field Control\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Voltage\u003c\/td\u003e\n      \u003ctd\u003e120 VAC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e0 to 132 VAC (47 to 63 Hz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e8 isolated points\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUser Input Current\u003c\/td\u003e\n      \u003ctd\u003e13 mA typical per point at rated voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Impedance\u003c\/td\u003e\n      \u003ctd\u003e10K ohms typical (reactive)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eON State Voltage \/ Current\u003c\/td\u003e\n      \u003ctd\u003e70 to 120 VAC \/ 5 to 15 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOFF State Voltage \/ Current\u003c\/td\u003e\n      \u003ctd\u003e0 to 20 VAC \/ 0 to 2.5 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResponse Time\u003c\/td\u003e\n      \u003ctd\u003eON: 10 ms typical (20 ms max); OFF: 20 ms typical (40 ms max)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIsolation\u003c\/td\u003e\n      \u003ctd\u003e250 VAC continuous, 1500 VAC for 1 minute (user input to logic\/frame ground)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBackplane Power Consumption\u003c\/td\u003e\n      \u003ctd\u003e40 mA maximum drawn from Bus Interface Unit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBus Interface Unit (BIU) Interface:\u003c\/strong\u003e Connects to the backplane to receive operating power and transmit 8 bits of serialized input data.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Block Options:\u003c\/strong\u003e Compatible with Field Control base styles including Box Terminals (IC670CHS002\/102), Barrier Terminals (IC670CHS001\/101), and Wire-to-Board Connectors (IC670CHS003\/103).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAuxiliary Terminal Blocks:\u003c\/strong\u003e Optional auxiliary terminal blocks can be utilized for expanded power distribution and field wiring termination.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure all system power and external 120VAC field supplies are turned off before installing or removing the module from the base.\u003c\/li\u003e\n  \u003cli\u003eVerify that the correct optional keying pins are set on the base and module to prevent incorrect insertion.\u003c\/li\u003e\n  \u003cli\u003eSecurely attach the module to the designated Field Control base unit, ensuring proper mating with backplane connectors.\u003c\/li\u003e\n  \u003cli\u003eConnect field input wiring to the appropriate terminal block connections, respecting the recommended wire gauge sizes (AWG 14 to 22 depending on terminal type).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770164339051,"sku":"IC670MDL233","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/IC670MDL233_1200x1200_36f67e60-19c7-4865-a9f3-a6c91374c48a.jpg?v=1787736985","url":"https:\/\/www.plcprotech.com\/products\/general-electric-ic670mdl233-field-control-discrete-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}