{"product_id":"general-electric-ic693mdl660-series-90-30-24-volt-dc-high-density-input-module","title":"General Electric IC693MDL660 Series 90-30 24 Volt DC High Density Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC693MDL660 is a high-density 24-volt DC input module designed for the Series 90-30 programmable logic controller (PLC) platform. This module provides 32 discrete input points arranged in four isolated groups of eight inputs, offering efficient space utilization and high-density signal processing for industrial automation systems. It features a removable terminal block design that allows direct field device wiring without requiring intermediate transition bases and cables.\u003c\/p\u003e\n\u003cp\u003eEngineered for reliable performance in demanding control environments, the IC693MDL660 supports selectable input filter times from 0.5 to 100 milliseconds to help suppress electrical noise. Configuration of this module requires Proficy Machine Edition Version 5.00 Service Pack 2 Logic Developer-PLC or later.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e32 discrete input points per module, organized into four isolated groups of eight\u003c\/li\u003e\n  \u003cli\u003eRated input voltage of 24 VDC with an input voltage range of 0 to 30 VDC\u003c\/li\u003e\n  \u003cli\u003eSelectable input filter times ranging from 0.5 to 100 ms for flexible noise rejection\u003c\/li\u003e\n  \u003cli\u003eOptical isolation rated at 250 VAC continuous and 1,500 VAC for one minute (field to backplane and group to group)\u003c\/li\u003e\n  \u003cli\u003eRemovable terminal block compatibility (Box-style IC694TBB032 and spring clamp IC694TBS032 available separately)\u003c\/li\u003e\n  \u003cli\u003eCompatible with Series 90-30 baseplates and PACSystems RX3i modular systems using Series 90-30 I\/O\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDiscrete manufacturing and assembly lines\u003c\/li\u003e\n  \u003cli\u003eProcess control and monitoring systems\u003c\/li\u003e\n  \u003cli\u003eMachine automation requiring high-density digital signal acquisition\u003c\/li\u003e\n  \u003cli\u003eConveyor and material handling control panels\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eGeneral Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003eIC693MDL660\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Platform\u003c\/td\u003e\n      \u003ctd\u003eSeries 90-30 PLC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eHigh Density DC Input Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e32 inputs (4 isolated groups of 8 inputs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e0 to 30 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Current (Typical)\u003c\/td\u003e\n      \u003ctd\u003e7.0 mA per point at rated voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n      \u003ctd\u003e11.5 to 30 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n      \u003ctd\u003e0 to 5 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOn-State Current (Max)\u003c\/td\u003e\n      \u003ctd\u003e3.2 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOff-State Current (Max)\u003c\/td\u003e\n      \u003ctd\u003e1.1 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Filter \/ Response Time\u003c\/td\u003e\n      \u003ctd\u003e0.5 to 100 ms (selectable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBackplane Power Consumption\u003c\/td\u003e\n      \u003ctd\u003e300 mA from 5V bus (all inputs on)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIsolation (Field to Backplane)\u003c\/td\u003e\n      \u003ctd\u003e250 VAC continuous; 1,500 VAC for 1 minute (optical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIsolation (Group to Group)\u003c\/td\u003e\n      \u003ctd\u003e250 VAC continuous; 1,500 VAC for 1 minute\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe module connects directly to a Series 90-30 baseplate slot. Field wiring is terminated externally using a removable terminal block (RTB), which must be ordered separately. Compatible terminal blocks include the IC694TBB032 (box-style) and IC694TBS032 (spring clamp).\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAlways disconnect rack power before installing or removing the module from the Series 90-30 baseplate.\u003c\/li\u003e\n  \u003cli\u003eEnsure proper seating of the module into the baseplate connector and secure retention screws.\u003c\/li\u003e\n  \u003cli\u003eUse shielded cables for field wiring in high-electromagnetic-interference (EMI) environments to maintain signal integrity.\u003c\/li\u003e\n  \u003cli\u003eVerify configuration settings in Proficy Machine Edition match physical switch or software parameters before system startup.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770136617323,"sku":"IC693MDL660","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/IC693MDL660_1200x1200_7b4b015f-79a8-4430-b378-8e861a3afdfd.jpg?v=1787736554","url":"https:\/\/www.plcprotech.com\/products\/general-electric-ic693mdl660-series-90-30-24-volt-dc-high-density-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}