{"product_id":"general-electric-ic697cmm721-series-90-70-carrierband-map-interface-module","title":"General Electric IC697CMM721 Series 90-70 Carrierband MAP Interface Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC697CMM721 is a high-performance Carrierband MAP Interface Module designed specifically for the Series 90-70 programmable controller platform. As part of the GEnet family of industrial automation solutions, this module provides a direct, high-speed connection between a Series 90-70 PLC and an IEEE 802.4 carrierband network. It implements the Manufacturing Automation Protocol (MAP) version 3.0 specification, enabling seamless multi-vendor interoperability within complex factory automation architectures.\u003c\/p\u003e\n\u003cp\u003eEquipped with an onboard modem daughter board and RAM-based protocol storage, the IC697CMM721 supports easy firmware updates without requiring hardware modifications. An integrated battery backup system maintains communication software integrity for at least six months during power loss. The single-slot module also features a 9-pin RS-232 serial DTE port for programmer connection and local GeneT System Manager (GSM) integration.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect IEEE 802.4 carrierband network interface for Series 90-70 PLC systems\u003c\/li\u003e\n  \u003cli\u003eSupports Manufacturing Automation Protocol (MAP) version 3.0 specifications\u003c\/li\u003e\n  \u003cli\u003e5 Mbps modem daughter board for high-performance real-time control applications\u003c\/li\u003e\n  \u003cli\u003eRAM-based communication software storage allows easy downloading and field upgrades\u003c\/li\u003e\n  \u003cli\u003eOnboard battery backup protects stored software against power loss for a minimum of six months\u003c\/li\u003e\n  \u003cli\u003eIntegrated 9-pin RS-232 serial port (DTE) for programmer or local GSM communication\u003c\/li\u003e\n  \u003cli\u003eFront-panel LED status indicators for Module OK, Online, and Status OK diagnostics\u003c\/li\u003e\n  \u003cli\u003eDedicated hardware restart and reload pushbutton for manual reset and download initiation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomated manufacturing plant floor networks\u003c\/li\u003e\n  \u003cli\u003eMulti-vendor PLC communication integration\u003c\/li\u003e\n  \u003cli\u003eReal-time industrial process control cells\u003c\/li\u003e\n  \u003cli\u003eLegacy GEnet Factory LAN architecture expansion\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eGeneral Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003eIC697CMM721\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Family\u003c\/td\u003e\n      \u003ctd\u003eSeries 90-70 \/ GEnet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eCarrierband MAP Interface Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSupported Protocol\u003c\/td\u003e\n      \u003ctd\u003eMAP Specification Version 3.0 (IEEE 802.4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Rate\u003c\/td\u003e\n      \u003ctd\u003e5 Mbps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSlot Requirement\u003c\/td\u003e\n      \u003ctd\u003eSingle slot in Series 90-70 PLC rack\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSerial Interface\u003c\/td\u003e\n      \u003ctd\u003e9-Pin RS-232 DTE Port\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSoftware Storage\u003c\/td\u003e\n      \u003ctd\u003eRAM with battery backup\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBattery Backup Retention\u003c\/td\u003e\n      \u003ctd\u003e6 months minimum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDiagnostics\u003c\/td\u003e\n      \u003ctd\u003eFront-panel LEDs (Module OK, Online, Status OK)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLAN Connector:\u003c\/strong\u003e Coaxial drop cable connector located on the lower front edge for network attachment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSerial Port:\u003c\/strong\u003e 9-pin D-sub RS-232 DTE port for connecting to local programming terminals or GSM systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBattery Connector:\u003c\/strong\u003e Internal connector supporting IC697ACC701 replacement batteries with secure drop-out protection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRestart Pushbutton:\u003c\/strong\u003e Recessed front-panel button for module reboot and download request functions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe IC697CMM721 module occupies a single slot in any standard Series 90-70 PLC rack. Ensure the rack is securely grounded using the safety ground wire connected to the modem and coaxial cable shield. When connecting to the carrierband network, use only recommended cable plant components to avoid damage not covered by equipment warranty. Always install a new backup battery before unplugging an old unit to preserve stored RAM data.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770186686827,"sku":"IC697CMM721","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/IC697CMM721_1200x1200_95a01826-1881-401a-99d0-56c86636df8e.jpg?v=1787737929","url":"https:\/\/www.plcprotech.com\/products\/general-electric-ic697cmm721-series-90-70-carrierband-map-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}