{"product_id":"general-electric-ic698cmx016-pacsystems-rx7i-control-memory-xchange-module","title":"General Electric IC698CMX016 PACSystems RX7i Control Memory Xchange Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IC698CMX016 is a PACSystems RX7i Control Memory Xchange (CMX) module designed to provide deterministic, high-speed data sharing among PLCs and other computing devices across a fiber optic network. Utilizing advanced reflective memory technology, this single-slot module allows up to 256 nodes to be interconnected in a daisy-chained loop, ensuring that any data written to a single node automatically updates all other compatible nodes on the network instantly without requiring CPU processing overhead.\u003c\/p\u003e\n\u003cp\u003eEngineered specifically for the RX7i main rack architecture, the IC698CMX016 features 16 MB of SDRAM user memory and communicates via a robust 2.12 Gbaud fiber optic interface. It supports dynamic packet sizes ranging from 4 to 64 bytes, delivering maximum network transfer rates up to 174 Mbytes\/s. Configuration of node parameters is handled entirely through Proficy Machine Edition Logic Developer-PLC software, eliminating the need for physical jumpers or switches.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePACSystems RX7i single-slot form factor for main rack installation\u003c\/li\u003e\n  \u003cli\u003e16 MB SDRAM user memory with parity support\u003c\/li\u003e\n  \u003cli\u003eHigh-speed 2.12 Gbaud fiber-optic network interface with LC-type connectors\u003c\/li\u003e\n  \u003cli\u003eAutomatic dynamic packet sizing from 4 to 64 bytes\u003c\/li\u003e\n  \u003cli\u003eSoftware configuration of all node parameters via Machine Edition\u003c\/li\u003e\n  \u003cli\u003eProgrammable VMEbus interrupt output with four general-purpose network interrupts\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDeterministic inter-controller data synchronization in distributed control systems\u003c\/li\u003e\n  \u003cli\u003eHigh-speed real-time process monitoring and multi-PLC communication\u003c\/li\u003e\n  \u003cli\u003eRedundant node data exchange and fault-tolerant industrial networking\u003c\/li\u003e\n  \u003cli\u003eIntegration of third-party computing workstations into RX7i control racks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number\u003c\/td\u003e\n      \u003ctd\u003eIC698CMX016\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBrand\u003c\/td\u003e\n      \u003ctd\u003eGeneral Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeries\u003c\/td\u003e\n      \u003ctd\u003ePACSystems RX7i\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUser Memory\u003c\/td\u003e\n      \u003ctd\u003e16 MB SDRAM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Voltage\u003c\/td\u003e\n      \u003ctd\u003e+5 VDC (sourced from rack power supply)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Requirements\u003c\/td\u003e\n      \u003ctd\u003e1.8 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNetwork Bandwidth\u003c\/td\u003e\n      \u003ctd\u003eUp to 174 Mbytes\/s\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNetwork Node Capacity\u003c\/td\u003e\n      \u003ctd\u003eUp to 256 nodes per network\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOptical Transceiver\u003c\/td\u003e\n      \u003ctd\u003eFiber optic LC type, conforms to IEC 61754-20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOptical Ferrule\u003c\/td\u003e\n      \u003ctd\u003eZirconium ceramic\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInsertion Loss\u003c\/td\u003e\n      \u003ctd\u003e0.35 dB maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eReturn Loss\u003c\/td\u003e\n      \u003ctd\u003e-30 dB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-20°C to +85°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n      \u003ctd\u003e6.299 in W x 9.187 in H (PCB form factor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUL Listed for Hazardous Locations (Class I, Division 2, Groups A, B, C, D)\u003c\/li\u003e\n  \u003cli\u003eConforms to IEC 61754-20 fiber optic standards\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53770191569259,"sku":"IC698CMX016","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ge-emerson-ic698rmx016_1200x1200_2db12b3b-f310-4d31-a712-3a3b0d06abc7.jpg?v=1787738089","url":"https:\/\/www.plcprotech.com\/products\/general-electric-ic698cmx016-pacsystems-rx7i-control-memory-xchange-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}