{"product_id":"general-electric-is200ectbg2ade-exciter-contact-terminal-board","title":"General Electric IS200ECTBG2ADE Exciter Contact Terminal Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe General Electric IS200ECTBG2ADE is an exciter contact terminal board engineered specifically for the GE EX2100 Excitation Control System. Operating exclusively in simplex mode, this component serves as a critical interface for monitoring and managing auxiliary signals in power generation applications. It handles vital turbine and generator status inputs while supplying controlled isolated power for internal contact wetting.\u003c\/p\u003e\n\u003cp\u003eDesigned to integrate seamlessly within the EX2100 architecture, the board interfaces with associated control and I\/O modules such as the EMIO and ESEL boards to process logic-level gate pulses and maintain system stability. Its robust hardware design ensures reliable operation in demanding industrial environments where precise excitation control and rapid fault response are required.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEngineered specifically for the GE EX2100 Excitation Control System platform\u003c\/li\u003e\n  \u003cli\u003eConfigured for simplex mode operation to support standard system architectures\u003c\/li\u003e\n  \u003cli\u003eProvides six auxiliary contact inputs, two trip contact outputs, and four Form-C relay contact outputs\u003c\/li\u003e\n  \u003cli\u003eEquipped with isolated +70V DC contact wetting power sourced from the EPSM module\u003c\/li\u003e\n  \u003cli\u003eMonitors critical generator protection and status inputs including 52G and 86G\u003c\/li\u003e\n  \u003cli\u003eDirectly interfaces with system management cards including EMIO and ESEL boards\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGas and steam turbine generator excitation control\u003c\/li\u003e\n  \u003cli\u003ePower generation plant automation and turbine management\u003c\/li\u003e\n  \u003cli\u003eIndustrial synchronous generator retrofits and upgrades\u003c\/li\u003e\n  \u003cli\u003eEX2100 excitation system maintenance and board replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eGeneral Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eEX2100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003eIS200ECTBG2ADE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eExciter Contact Terminal Board\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Mode\u003c\/td\u003e\n      \u003ctd\u003eSimplex Mode\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAuxiliary Contact Inputs\u003c\/td\u003e\n      \u003ctd\u003e6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTrip Contact Outputs\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eForm-C Relay Outputs\u003c\/td\u003e\n      \u003ctd\u003e4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eContact Wetting Voltage\u003c\/td\u003e\n      \u003ctd\u003eIsolated +70V DC (from EPSM module)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMonitored Inputs\u003c\/td\u003e\n      \u003ctd\u003e52G (Generator Status), 86G (Lockout Mechanism)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCompatible System Modules\u003c\/td\u003e\n      \u003ctd\u003eEMIO, ESEL, EXTB, EACF, EPCT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe IS200ECTBG2ADE features dedicated terminal blocks for field wiring termination of auxiliary inputs, trip outputs, and Form-C relay contacts. Internal ribbon cable and backplane connectors establish high-speed communication and signal routing with the EMIO management board and adjacent EX2100 system racks.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure all rack power and excitation system feeds are completely de-energized before handling the terminal board.\u003c\/li\u003e\n  \u003cli\u003eObserve standard electrostatic discharge (ESD) precautions by wearing a grounded wrist strap during handling and installation.\u003c\/li\u003e\n  \u003cli\u003eVerify that the board is installed in the designated EX2100 rack slot configured for simplex operation.\u003c\/li\u003e\n  \u003cli\u003eInspect all field wiring terminations for correct polarity and secure connection before restoring system power.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695414243691,"sku":"IS200ECTBG2A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is200ectbg2ade-hvac-control-system-board-eshu3ura3gu_2e426b45-a949-4ebb-bc62-42085fa6286c.jpg?v=1766135179","url":"https:\/\/www.plcprotech.com\/products\/general-electric-is200ectbg2ade-exciter-contact-terminal-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}