{"product_id":"general-electric-is200trlyh1bgg-mark-vie-coil-sensing-terminal-board","title":"General Electric IS200TRLYH1BGG Mark VIe Coil Sensing Terminal Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS200TRLYH1BGG\u003c\/strong\u003e functions as a specialized coil sensing terminal board designed for the General Electric \u003cstrong\u003eMark VIe\u003c\/strong\u003e control system. It serves as a hardware interface to handle relay-based control and signaling architectures, accommodating up to 12 plug-in magnetic relays. The board features a segmented circuit layout where the first six relay channels are jumper-configurable to enable dry, Form-C contact outputs or to drive external field solenoids. Channels 7 through 11 provide unpowered, isolated Form-C contacts to manage standard auxiliary signaling, while the 12th channel is dedicated to special applications, such as ignition transformers. The \u003cstrong\u003eIS200TRLYH1BGG\u003c\/strong\u003e includes internal diagnostic fault loops that continuously cross-reference actual coil current parameters against incoming system commands to verify component operation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccommodates up to 12 plug-in magnetic relays to support multi-channel control configurations.\u003c\/li\u003e\n\u003cli\u003eFeatures 6 configurable relay circuits utilizing onboard jumpers for Form-C dry contact selection or external solenoid excitation.\u003c\/li\u003e\n\u003cli\u003eProvides field solenoid power distributions compatible with 125 V DC, 115\/230 V AC, or optional 24 V DC lines.\u003c\/li\u003e\n\u003cli\u003eIntegrates individual jumper-selectable fuses alongside on-board voltage suppression loops for field solenoid protection.\u003c\/li\u003e\n\u003cli\u003eIncludes 5 dedicated channels (Relays 7-11) configured strictly for unpowered isolated Form-C contact outputs.\u003c\/li\u003e\n\u003cli\u003eHouses 1 specialized application relay channel (Output 12) featuring a standalone 7 A current rating for equipment like ignition transformers.\u003c\/li\u003e\n\u003cli\u003eEmploys real-time diagnostic logic to generate faults for loss of relay excitation, coil current mismatches, or disconnected I\/O communication cables.\u003c\/li\u003e\n\u003cli\u003eSafeguards hardware operations through automatic de-energization of relays upon detection of an unplugged cable or I\/O board communication loss.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed relay control systems inside Mark VIe control architectures.\u003c\/li\u003e\n\u003cli\u003ePower plant solenoid valve activation and diagnostic monitoring.\u003c\/li\u003e\n\u003cli\u003eSpecial ignition transformer control operations via dedicated high-rating channels.\u003c\/li\u003e\n\u003cli\u003eIsolated dry-contact signaling arrays within power generation networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIS200TRLYH1BGG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCoil sensing terminal board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Number of Relay Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Inrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSilver cad-oxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Response Time On\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Response Time Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Load Current (125 V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Load Current (24 V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Load Current (115\/230 V AC, 50\/60 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Load Current (Relay 12 Only)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A at 115 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Contact Rating (24 V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A resistive, 2 A inductive (L\/R = 7 ms) without suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Contact Rating (125 V DC, No Suppression)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A resistive, 0.2 A inductive (L\/R = 7 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Contact Rating (125 V DC, With Suppression)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A resistive, 0.65 A inductive (L\/R = 150 ms) with MOV across load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 65 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.8 cm wide x 33.02 cm high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Manufacture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States of America (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Cross-Connection Prevention:\u003c\/strong\u003e During 240 V AC installation procedures, prevent unexpected cross-connections between the 240 V AC and DC distribution loops to ensure voltage transients do not exceed the onboard Transorb thresholds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Neutral Grounding:\u003c\/strong\u003e Ensure that the AC supply operates with a grounded neutral line. In mixed 125 V DC \/ 120 V AC setups, confirm the combined peak transient voltages sit within the acceptable Transorb safety margin.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Securement:\u003c\/strong\u003e Mount the terminal board securely into the Mark VIe enclosure frame utilizing standard mounting dimensions (17.8 cm x 33.02 cm) to stabilize the plug-in relays against vibrational mechanical stress.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695409426795,"sku":"IS200TRLYH1BGG","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is200trlyh1bgg-relay-output-terminal-board-ywtzmttam2z_af7c0e49-4533-4591-9dcc-06607ba8163d.jpg?v=1766135005","url":"https:\/\/www.plcprotech.com\/products\/general-electric-is200trlyh1bgg-mark-vie-coil-sensing-terminal-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}