{"product_id":"general-electric-is220paich1a-mark-vie-analog-i-o-pack","title":"General Electric IS220PAICH1A Mark VIe Analog I\/O Pack","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS220PAICH1A\u003c\/strong\u003e is an analog I\/O pack manufactured by General Electric Company USA (GE Industrial Systems) as part of the Mark VIe Series for turbine control and automated drive management systems. This pack interfaces directly with compatible terminal boards to handle dual-way analog input and output signal transitions. It supports specialized control configurations for gas, steam, and alternative energy wind turbine assemblies. Designed for installation inside 13-slot or 21-slot VME racks, the \u003cstrong\u003eIS220PAICH1A\u003c\/strong\u003e typically operates within a Triple Modular Redundant (TMR) control architecture consisting of individual control modules, dedicated internal I\/O nets, and central processor cards. The module integrates a conformal protective circuit coating to withstand aggressive industrial environments and features four front-facing status indicators paired with a base-mounted I\/O port.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProcesses diverse industrial analog input and output channels for turbine control systems\u003c\/li\u003e\n\u003cli\u003eDesigned for deployment in Triple Modular Redundant (TMR) network architectures\u003c\/li\u003e\n\u003cli\u003eFeatures an A-rated functional revision incorporating a conformal PCB defensive coating\u003c\/li\u003e\n\u003cli\u003eEquipped with four faceplate status indicators for instant diagnostics\u003c\/li\u003e\n\u003cli\u003eBuilt with an interface port located at the bottom of the casing assembly\u003c\/li\u003e\n\u003cli\u003eApproved for operational safety across both non-hazardous and specialized hazardous locations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGas turbine automated drive assembly management\u003c\/li\u003e\n\u003cli\u003eSteam turbine loop control systems\u003c\/li\u003e\n\u003cli\u003eAlternative energy wind turbine control applications\u003c\/li\u003e\n\u003cli\u003eDistributed control architectures requiring reliable TMR verification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric Company USA (GE Industrial Systems)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eIS220PAICH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003ePAIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog I\/O Pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Type\u003c\/td\u003e\n\u003ctd\u003eIS220 Standard Module with Conformal PCB Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-22 to 149 Fahrenheit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Power Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e27.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Power Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e28.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e28.6 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power Supply Current\u003c\/td\u003e\n\u003ctd\u003e0.49 A dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Input Voltage (Channels 1-8)\u003c\/td\u003e\n\u003ctd\u003e10 V dc (with 20 mA dc Max Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Input Voltage (Channels 9-10)\u003c\/td\u003e\n\u003ctd\u003e5 V dc (with 20 mA dc Max Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Voltage\u003c\/td\u003e\n\u003ctd\u003e16.3 V dc (with 20 mA dc Max Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Analog Transmitter Voltage\u003c\/td\u003e\n\u003ctd\u003e25.2 V dc (with 21 mA dc Max Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCompatible Model \/ Function\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS200STAIH1A\u003c\/td\u003e\n\u003ctd\u003eInput-Output Terminal Board Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS200STAIH2A\u003c\/td\u003e\n\u003ctd\u003eInput-Output Terminal Board Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS20TBAIH1C\u003c\/td\u003e\n\u003ctd\u003eInput-Output Terminal Board Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBottom I\/O Port\u003c\/td\u003e\n\u003ctd\u003eDedicated port for local input\/output link routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Deployment:\u003c\/strong\u003e Install the I\/O pack within its designated location inside a compatible 13-slot or 21-slot VME rack assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Board Mating:\u003c\/strong\u003e Ensure correct structural connection with approved input-output terminal boards, including the TBAI (such as IS20TBAIH1C) or STAI (such as IS200STAIH1A and IS200STAIH2A) options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Integrity:\u003c\/strong\u003e Provide a direct current supply source within the critical boundaries of 27.4 VDC minimum and 28.6 VDC maximum, targeting a nominal voltage of 28.0 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTMR Setup Requirements:\u003c\/strong\u003e Align network cables and node addresses to sync properly with the independent control modules and individual I\/O nets forming the Triple Modular Redundant loop.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eClass I, Div. 2, Groups A, B, C, D Standard: ANSI\/ISA - 12.12.01-2015\u003c\/li\u003e\n\u003cli\u003eClass I, Zone 2, Group IIC\u003c\/li\u003e\n\u003cli\u003eATEX Zone 2, Group IIC\u003c\/li\u003e\n\u003cli\u003eNon-Hazardous Location Certification: UL E207865\u003c\/li\u003e\n\u003cli\u003eHazardous Location Certifications: UL E207685, UL DEMKO 12 ATEX 1114875X\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695417487723,"sku":"IS220PAICH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is220paich1a-analog-i-o-pack-xfcyusd3oz3_c2891e95-5e3c-40a9-a491-5d209ee3da05.jpg?v=1766135294","url":"https:\/\/www.plcprotech.com\/products\/general-electric-is220paich1a-mark-vie-analog-i-o-pack","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}