{"product_id":"general-electric-is220yaics1aj-mark-vies-safety-analog-i-o-module","title":"General Electric IS220YAICS1AJ Mark VIeS Safety Analog I\/O Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS220YAICS1AJ\u003c\/strong\u003e is a revision variant of the IS220YAICS1A safety analog I\/O module designed for high-reliability signal interface and processing within GE Mark VIeS Safety Control Systems. The module processes analog input and output signals for functional safety applications in critical process industries.\u003c\/p\u003e\n\u003cp\u003eIt communicates via dual redundant Ethernet interfaces to system controllers, using built-in digital signal processing and analog-to-digital converter (ADC) architecture to execute continuous diagnostics and input signal conditioning.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual redundant Ethernet communication channels for high-availability system integration.\u003c\/li\u003e\n\u003cli\u003eIntegrated analog-to-digital converter (ADC) and digital signal processing circuitry.\u003c\/li\u003e\n\u003cli\u003eOnboard power supply filtering and transient voltage surge mitigation.\u003c\/li\u003e\n\u003cli\u003eForm-factor compatible with DIN rail-mountable terminal board interfaces.\u003c\/li\u003e\n\u003cli\u003eIntegrated field wiring terminal board support with intrinsic safety options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmergency Shutdown Systems (ESD)\u003c\/li\u003e\n\u003cli\u003eBurner Management Systems (BMS)\u003c\/li\u003e\n\u003cli\u003eTurbomachinery safety shutdown and trip logic\u003c\/li\u003e\n\u003cli\u003eCritical process industry safety instrumented functions (SIF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS220YAICS1AJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage Min\u003c\/td\u003e\n\u003ctd\u003e27.4 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage Nominal\u003c\/td\u003e\n\u003ctd\u003e28.0 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage Max\u003c\/td\u003e\n\u003ctd\u003e28.6 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Current Max\u003c\/td\u003e\n\u003ctd\u003e0.49 A dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs (1-8) Voltage Range\u003c\/td\u003e\n\u003ctd\u003e-10 to 10 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs (1-8) Current Range\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs (9-10) Voltage Range\u003c\/td\u003e\n\u003ctd\u003e-5 to 5 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs (9-10) Current Range\u003c\/td\u003e\n\u003ctd\u003e-1 to 20 mA dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 16.3 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs Current Range\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Transmitter Power Voltage Min\u003c\/td\u003e\n\u003ctd\u003e22.8 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Transmitter Power Voltage Nominal\u003c\/td\u003e\n\u003ctd\u003e24.0 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Transmitter Power Voltage Max\u003c\/td\u003e\n\u003ctd\u003e25.2 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Transmitter Power Current Max\u003c\/td\u003e\n\u003ctd\u003e21 mA dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTB1.45\u003c\/td\u003e\n\u003ctd\u003eSignal 1 (+) (STAI Terminal Board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTB1.46\u003c\/td\u003e\n\u003ctd\u003eReturn 1 (-) (STAI Terminal Board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTB1.47\u003c\/td\u003e\n\u003ctd\u003eSignal 2 (+) (STAI Terminal Board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTB1.48\u003c\/td\u003e\n\u003ctd\u003eReturn 2 (-) (STAI Terminal Board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTB2.45\u003c\/td\u003e\n\u003ctd\u003eSignal 1 (+) (STAI Terminal Board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTB2.46\u003c\/td\u003e\n\u003ctd\u003eReturn 1 (-) (STAI Terminal Board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTB2.47\u003c\/td\u003e\n\u003ctd\u003eSignal 2 (+) (STAI Terminal Board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTB2.48\u003c\/td\u003e\n\u003ctd\u003eReturn 2 (-) (STAI Terminal Board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Field wiring terminals are intended for copper conductors with insulation locally removed; ensure proper system grounding practices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Requirements:\u003c\/strong\u003e Use only copper conductors rated 90 degC minimum up to 60 degC product ambient, and 105 degC minimum above 60 degC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Installation:\u003c\/strong\u003e Install inside an enclosure that requires a tool or key to open and provides an ingress protection rating suitable for the location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Restrictions:\u003c\/strong\u003e Provision shall be made to limit power supply transient voltages to less than 140% of the peak rated power supply voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Operations:\u003c\/strong\u003e Do not connect or disconnect modules, connectors, cables, or terminal board wiring while circuits are energized unless the area is known to be non-hazardous.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53705363095915,"sku":"IS220YAICS1AJ","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/IS220YAICS1AJ_1200x1200_3eea3c73-8bdc-4acb-a7f7-7f300b9a2c84.jpg?v=1786426710","url":"https:\/\/www.plcprotech.com\/products\/general-electric-is220yaics1aj-mark-vies-safety-analog-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}