{"product_id":"hima-f-6705-hiquad-x-2-fold-converter-digital-analog-module","title":"HIMA F 6705 HIQuad X 2-Fold Converter Digital\/Analog Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe HIMA \u003cstrong\u003eF 6705\u003c\/strong\u003e is a 2-fold digital\/analog converter designed for safety-related signal conversion in source or sink mode. The module operates within safety-instrumented systems up to Requirement Class \u003cstrong\u003eAK 1 ... 6\u003c\/strong\u003e and receives data via the internal \u003cstrong\u003eVO bus\u003c\/strong\u003e. The \u003cstrong\u003eF 6705\u003c\/strong\u003e provides two individually galvanically isolated analog outputs capable of delivering \u003cstrong\u003e0\/4 ... 20 mA\u003c\/strong\u003e current signals with integrated safety shutdown isolation. During continuous operation, automated internal testing routines continuously verify the linearity of the onboard \u003cstrong\u003e12-bit D\/A converter\u003c\/strong\u003e, cross-talk between individual output channels, and safety shutdown capabilities.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo individually galvanically isolated analog output channels with safety isolation\u003c\/li\u003e\n\u003cli\u003eConfigurable operation for either source mode or sink mode per channel\u003c\/li\u003e\n\u003cli\u003eContinuous automated testing of D\/A converter linearity, channel cross-talk, and safety shutdown\u003c\/li\u003e\n\u003cli\u003eSupport for parallel redundant output configurations and bipolar current mode (-20 mA to +20 mA)\u003c\/li\u003e\n\u003cli\u003eIntegrated safety shutdown mechanism for fail-safe system operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSafety-instrumented systems (SIS) requiring Requirement Class AK 1 ... 6 compliance\u003c\/li\u003e\n\u003cli\u003eFail-safe process control loops using 0\/4 ... 20 mA analog outputs\u003c\/li\u003e\n\u003cli\u003eRedundant and bipolar current output control configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number \/ Model\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eF 6705\u003c\/td\u003e\n\u003ctd\u003e2-fold Converter Digital\/Analog Module, Safety Related\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZ 7126 \/ F 6705\u003c\/td\u003e\n\u003ctd\u003eFront Cable Plug Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZ 7126\/6705\/C..\u003c\/td\u003e\n\u003ctd\u003eCable Plug for F 6705 Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e2 channels, 0\/4 ... 20 mA, individual galvanically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Modes\u003c\/td\u003e\n\u003ctd\u003eSource mode or sink mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequirement Class\u003c\/td\u003e\n\u003ctd\u003eAK 1 ... 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12 bits (4095 steps: 0 = 0 mA, 3840 = 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurden Resistance (Source Mode)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 550 Ohm including line resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurden Resistance (Sink Mode)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= (UQ - 10 V) \/ 21.2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource Voltage (UQ)\u003c\/td\u003e\n\u003ctd\u003e10 ... 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic Error\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 0.2% (40 uA) at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Error\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 0.4% at 0 ... +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Line Length\u003c\/td\u003e\n\u003ctd\u003e1000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectric Strength\u003c\/td\u003e\n\u003ctd\u003e250 V against Analog-GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic Status with Plug-in (Sink Mode)\u003c\/td\u003e\n\u003ctd\u003eI \u0026lt;= 40 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e5 V DC: 85 mA, 24 V DC: 130 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpace Requirement\u003c\/td\u003e\n\u003ctd\u003e4 TE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eb8\u003c\/td\u003e\n\u003ctd\u003eChannel 1 Output Line (WS \/ White)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eb6\u003c\/td\u003e\n\u003ctd\u003eChannel 1 Signal Line (br \/ Brown)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eb4\u003c\/td\u003e\n\u003ctd\u003eChannel 1 Signal Line (rs \/ Pink)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eb10\u003c\/td\u003e\n\u003ctd\u003eChannel 1 Signal Line (gr \/ Grey)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eb24\u003c\/td\u003e\n\u003ctd\u003eChannel 2 Output Line (gn \/ Green)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eb22\u003c\/td\u003e\n\u003ctd\u003eChannel 2 Signal Line (ge \/ Yellow)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eb20\u003c\/td\u003e\n\u003ctd\u003eChannel 2 Signal Line (rt \/ Red)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eb26\u003c\/td\u003e\n\u003ctd\u003eChannel 2 Signal Line (bl \/ Blue)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eb28\u003c\/td\u003e\n\u003ctd\u003eL- Flat Pin Connection (SW \/ Black)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eb32\u003c\/td\u003e\n\u003ctd\u003eL+ Flat Pin Connection (rt \/ Red)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth Bar\u003c\/td\u003e\n\u003ctd\u003eFlat pin plug 6.3 x 0.8 mm for cable screen (ge-gn \/ Yellow-Green)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnused Channels\u003c\/strong\u003e: Connect a jumper between terminals b6 and b8 for Channel 1, or between b22 and b24 for Channel 2, to avoid module error messages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding\u003c\/strong\u003e: Connect the 6.3 x 0.8 mm flat pin plug of the cable screen directly to the earth bar located beneath the module slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Operation\u003c\/strong\u003e: Paralleled channels must operate in the same mode (source or sink). Total burden resistance must be halved, and current generation should be balanced across both channels to minimize thermal drift.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBipolar Operation\u003c\/strong\u003e: When generating -20 mA to +20 mA outputs using two modules, configure Module 1 for positive current and Module 2 for negative current. Control logic must ensure only one module outputs current at a given time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard \/ Certification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTÜV\u003c\/td\u003e\n\u003ctd\u003eApproved for safety-related applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003ctd\u003eCE Compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequirement Class\u003c\/td\u003e\n\u003ctd\u003eAK 1 ... 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS\u003c\/td\u003e\n\u003ctd\u003eIntrinsic Safety Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":53710889484651,"sku":"F6705","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/F6705_001_1200x1200_39d1464b-5b97-430a-86d6-fa9dd058d83c.jpg?v=1786512028","url":"https:\/\/www.plcprotech.com\/products\/hima-f-6705-hiquad-x-2-fold-converter-digital-analog-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}