{"product_id":"hima-f-6705-safety-related-2-fold-digital-to-analog-converter-module","title":"HIMA F 6705 Safety-Related 2-Fold Digital-to-Analog Converter Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA F 6705\u003c\/strong\u003e is a safety-related, 2-fold digital-to-analog converter module engineered for high-reliability process automation and safety-critical configurations. This device supports rigorous safety loop protocols across requirement classes AK 1 through AK 6. Featuring two individual galvanically isolated analog outputs with comprehensive safety isolation, the module integrates an embedded safety shutdown mechanism compatible with both source and sink operating modes. The \u003cstrong\u003eF 6705\u003c\/strong\u003e runs complete internal diagnostic self-test routines continuously during operation to secure functional integrity, verifying system parameters and preventing signal cross-talk.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated Diagnostics:\u003c\/strong\u003e The module executes automatic, full self-test routines during active operation, monitoring the linearity of the DA converter, cross-talk between individual channels, safety shutdown paths, and signal resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Isolation:\u003c\/strong\u003e Individual galvanic isolation across output paths is integrated with hardware-level safety isolation and a dedicated safety shutdown function.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Operating Modes:\u003c\/strong\u003e Flexible configuration capabilities enable independent output assignment for source mode or sink mode operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Resolution Conversion:\u003c\/strong\u003e An integrated 12-bit digital-to-analog converter provides 4,095 distinct operating steps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Functional Wiring:\u003c\/strong\u003e The module accommodates standard front cable plug installations and supports specialized configurations, including redundant current connections and bipolar current operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSafety-instrumented loops demanding precise analog control across requirement classes AK 1 through AK 6.\u003c\/li\u003e\n\u003cli\u003eRedundant current distribution loops using dual-channel configurations to maintain continuous signal output to the burden.\u003c\/li\u003e\n\u003cli\u003eBipolar current output applications ranging from -20 mA to +20 mA through synchronized multi-module pairings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHIMA Paul Hildebrandt GmbH + Co KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-fold digital-to-analog converter, safety-related\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequirement Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAK 1 to AK 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\/4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bits (4,095 steps); 0 = 0 mA, 3,840 = 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurden RB — Source Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 550 Ω, including line resistance to the burden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurden RB — Sink Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ (UQ - 10 V) \/ 21.2 mA, where UQ is the source voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic Error\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 0.2% (40 µA) at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Error\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 0.4% at 0 to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 1,000 m, subject to burden limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectric Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V against Analog GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic Status with Plug-In\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI ≤ 40 µA in sink mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSource Voltage UQ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 to 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpace Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 TE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V DC: 85 mA; 24 V DC: 130 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ch4\u003eLead Marking Cable Plug — Z 7126\/6705\/C..\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eChannel\u003c\/th\u003e\n\u003cth\u003eConnection Pin\u003c\/th\u003e\n\u003cth\u003eColor\u003c\/th\u003e\n\u003cth\u003eCable Specification \/ Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eb8\u003c\/td\u003e\n\u003ctd\u003eWS\u003c\/td\u003e\n\u003ctd\u003eLIYCY cable, 8 × 0.5 mm², length 750 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eb6\u003c\/td\u003e\n\u003ctd\u003ebr\u003c\/td\u003e\n\u003ctd\u003eLIYCY cable, 8 × 0.5 mm², length 750 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eb4\u003c\/td\u003e\n\u003ctd\u003ers\u003c\/td\u003e\n\u003ctd\u003eLIYCY cable, 8 × 0.5 mm², length 750 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eb10\u003c\/td\u003e\n\u003ctd\u003egr\u003c\/td\u003e\n\u003ctd\u003eLIYCY cable, 8 × 0.5 mm², length 750 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eb24\u003c\/td\u003e\n\u003ctd\u003egn\u003c\/td\u003e\n\u003ctd\u003eLIYCY cable, 8 × 0.5 mm², length 750 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eb22\u003c\/td\u003e\n\u003ctd\u003ege\u003c\/td\u003e\n\u003ctd\u003eLIYCY cable, 8 × 0.5 mm², length 750 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eb20\u003c\/td\u003e\n\u003ctd\u003ert\u003c\/td\u003e\n\u003ctd\u003eLIYCY cable, 8 × 0.5 mm², length 750 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eb26\u003c\/td\u003e\n\u003ctd\u003ebl\u003c\/td\u003e\n\u003ctd\u003eLIYCY cable, 8 × 0.5 mm², length 750 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eL−\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eb28\u003c\/td\u003e\n\u003ctd\u003esw\u003c\/td\u003e\n\u003ctd\u003eFlat pin plug, 2.8 × 0.8 mm; length 120 mm; conductor cross-section 1 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eL+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eb32\u003c\/td\u003e\n\u003ctd\u003ert\u003c\/td\u003e\n\u003ctd\u003eFlat pin plug, 2.8 × 0.8 mm; length 120 mm; conductor cross-section 1 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003ege-gn\u003c\/td\u003e\n\u003ctd\u003eFlat pin plug, 6.3 × 0.8 mm; connected to the earth bar; conductor cross-section 2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnused Channel Termination:\u003c\/strong\u003e To prevent module error messages, unused channels must be terminated with a hardware jumper across pins b6-b8 for channel 1 and pins b22-b24 for channel 2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e The yellow-green cable screen must be grounded through the 6.3 × 0.8 mm flat pin plug directly to the earth bar below the module slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Connection Rule:\u003c\/strong\u003e Parallel output channels must operate in the same mode. Both channels must use either source mode or sink mode. To improve load balancing and limit thermal errors, program each channel to supply half of the total target loop current, IG, to the burden resistance. In parallel redundant operation, the permissible total burden resistance is halved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBipolar Connection Constraints:\u003c\/strong\u003e For signed current output from -20 mA to +20 mA, only one module may actively generate or consume current at any time. This switching constraint must be implemented in the user application program.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTÜV\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"HIMA","offers":[{"title":"Default Title","offer_id":52695390814571,"sku":"F 6705","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/hima-f6705-analog-output-module-kac00lvi2hd_8b082660-163e-4c37-a18b-6be9b3176ceb.jpg?v=1766133070","url":"https:\/\/www.plcprotech.com\/products\/hima-f-6705-safety-related-2-fold-digital-to-analog-converter-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}