{"product_id":"hima-f-7133-h51q-system-family-4-fold-power-distribution-module","title":"HIMA F 7133 H51q System Family 4-Fold Power Distribution Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA F 7133\u003c\/strong\u003e is a non-interactive 4-fold power distribution module designed for the \u003cstrong\u003eH51q System Family\u003c\/strong\u003e to provide fuse monitoring and L- distribution. The module functions within the I\/O subrack (occupying slots 18 to 21) to supply and protect I\/O modules, sensor contacts, and actuator circuits. It incorporates four miniature fuses that provide line protection, with each fuse monitored via an internal evaluation logic block. Power for the I\/O modules is fed into the rear side of the power distribution modules via XG. 7\/8\/9\/10, allowing specific slots to allocate power to designated groups of I\/O slots. Built-in failure signalization is achieved through dedicated front-panel LEDs and an integrated relay contact to report missing or faulty fuse states safely.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 4-channel power distribution with independent fuse protection for each current path.\u003c\/li\u003e\n\u003cli\u003eIntegrates evaluation logic to monitor the operational state of each miniature fuse continuously.\u003c\/li\u003e\n\u003cli\u003eFeatures front-panel LED indicators that stay on when a path is functional, flash when a fuse is faulty or missing, and turn off if supply voltage fails.\u003c\/li\u003e\n\u003cli\u003eEquipped with a safety-related relay contact that remains closed when all fuses are functional and de-energizes automatically if any fuse is missing or faulty.\u003c\/li\u003e\n\u003cli\u003eDesigned as a non-interactive module ensuring isolated line protection across subrack assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e24 V DC power supply and distribution for safe routing to I\/O slots within HIMA safety subracks.\u003c\/li\u003e\n\u003cli\u003eFused power circuit distribution for external sensors and actuator contacts.\u003c\/li\u003e\n\u003cli\u003eFailure-signaling and monitored power marshalling in industrial automation and safety-instrumented systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Type Designation\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eAlternative Designation\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eF 7133\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eF7133\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-fold power distribution with fuse monitoring and L- distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHIMA Paul Hildebrandt GmbH + Co KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emax. 4 A slow blow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eapprox. 100 ms (relay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoadability of the Relay Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 V\/4 A (continuous load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Voltage (Fuse Tripped)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current (Fuse Tripped)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Voltage (Missing Supply)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emax. 3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual Current (Missing Supply)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpace Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 TE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC: 60 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Contacts 1, 2, 3, 4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection for L+ resp. EL+ to supply the I\/O modules and sensor contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Contact L-\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection for L- distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRear Contacts d6, d10, d14, d18\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminals for 24 V supply of one I\/O slot each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Contacts d22\/z24\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafety monitoring loop contact (closed when all fuses are in order)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubrack Positioning\u003c\/strong\u003e: Install the module into slots 18 to 21 of the I\/O subrack based on the specific group of I\/O slots requiring power distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Setup\u003c\/strong\u003e: Wire the supply inputs directly to the front-side contact pins (1, 2, 3, 4, and L-) via the front cable plug to establish the monitoring circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear Connection Check\u003c\/strong\u003e: Secure the power feed to the rear side of the modules using XG. 7\/8\/9\/10 connectors for proper distribution to the bus board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":52695393501547,"sku":"F7133","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/hima-f7133-4-fold-power-distribution-module-y2r3mrb10db_e1c1df89-4259-498d-97c5-754ce30cb0f5.jpg?v=1766133169","url":"https:\/\/www.plcprotech.com\/products\/hima-f-7133-h51q-system-family-4-fold-power-distribution-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}