{"product_id":"hima-f3349-h41q-h51q-system-digital-output-module","title":"HIMA F3349 H41q\/H51q System Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA F3349\u003c\/strong\u003e is a digital output module engineered for the H41q and H51q safety-related automation systems. Designed to maximize process availability, the module features a channel-by-channel shutdown mechanism. In the event of a single channel failure, only the affected channel is isolated and shut down, while all other healthy channels continue to operate without interruption. This localized fault tolerance ensures continuous production and system stability. The device integrates seamlessly into the 2oo4D\/QMR (Quadruple Modular Redundant) architecture of the H41q\/H51q systems and is configured using the IEC-61131-3 compliant ELOP II engineering tool.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChannel-by-channel fault isolation and shutdown\u003c\/li\u003e\n\u003cli\u003eMaintains active operation of healthy channels during a single-channel fault\u003c\/li\u003e\n\u003cli\u003eIncreases overall process availability and system fault tolerance\u003c\/li\u003e\n\u003cli\u003eFully compatible with HIMA H41q and H51q safety system architectures\u003c\/li\u003e\n\u003cli\u003eSupports online module replacement without process interruption\u003c\/li\u003e\n\u003cli\u003eConfigurable via ELOP II software with drag-and-drop functionality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmergency shut-down systems (ESD)\u003c\/li\u003e\n\u003cli\u003eBurner management systems (BMS)\u003c\/li\u003e\n\u003cli\u003eFire and gas monitoring systems (F\u0026amp;G)\u003c\/li\u003e\n\u003cli\u003eHigh-integrity pressure protection systems (HIPPS)\u003c\/li\u003e\n\u003cli\u003eChemical and petrochemical process automation\u003c\/li\u003e\n\u003cli\u003eOffshore drilling platform safety circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eH41q\/H51q Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003e2oo4D\/QMR (Quadruple Modular Redundant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eUp to SIL 3 \/ AK 6 (in mono-configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Replacement\u003c\/td\u003e\n\u003ctd\u003eOnline replacement supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming System\u003c\/td\u003e\n\u003ctd\u003eELOP II (IEC 61131-3 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the device within standard 19-inch subracks designated for H41q or H51q systems.\u003c\/li\u003e\n\u003cli\u003eThe module supports online replacement; defective units can be swapped during active operation without stopping the system.\u003c\/li\u003e\n\u003cli\u003ePerform all configuration, diagnostics, and logic testing offline or online using the ELOP II engineering tool.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding and shielding protocols are followed as per standard HIMA backplane installation requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 61508 to SIL 3\u003c\/li\u003e\n\u003cli\u003eDIN V 19250 to AK 6\u003c\/li\u003e\n\u003cli\u003eEN 954-1 to category 4\u003c\/li\u003e\n\u003cli\u003eprEN 50156\u003c\/li\u003e\n\u003cli\u003eNFPA 8501, NFPA 8502, NFPA 72\u003c\/li\u003e\n\u003cli\u003eEN 54-2\u003c\/li\u003e\n\u003cli\u003eEN 61000, EN 50082-2, EN 50081-2, EN 61131-2\u003c\/li\u003e\n\u003cli\u003eATEX 94\/9\/EG, EN 1127-1\u003c\/li\u003e\n\u003cli\u003eFactory Mutual (FM)\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eGOST R\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":52695392813419,"sku":"F3349","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/hima-f3349-digital-i-o-module-owdrit2rt10_38c11f18-d439-4add-af89-43c916e8e99f.jpg?v=1766133135","url":"https:\/\/www.plcprotech.com\/products\/hima-f3349-h41q-h51q-system-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}