{"product_id":"hima-himatrix-f2-do-8-01-safety-related-remote-i-o-module","title":"HIMA HIMatrix F2 DO 8 01 Safety-Related Remote I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA F2 DO 8 01\u003c\/strong\u003e (also designated as \u003cstrong\u003eF2DO801\u003c\/strong\u003e) is a compact, safety-related remote I\/O unit housed in a metal enclosure and featuring 8 safety-related relay outputs. Designed for safety shutdown applications up to SIL 3, the \u003cstrong\u003eF2 DO 8 01\u003c\/strong\u003e extends the I\/O capacity of \u003cstrong\u003eHIMax\u003c\/strong\u003e and \u003cstrong\u003eHIMatrix\u003c\/strong\u003e controllers over \u003cstrong\u003esafeethernet\u003c\/strong\u003e communication.\u003c\/p\u003e\n\u003cp\u003eEach output channel on the \u003cstrong\u003eF2 DO 8 01 (F2DO801)\u003c\/strong\u003e incorporates two safety relays with forcibly guided contacts and one standard relay, providing potential-free normally open contact operation. The module operates on 24 VDC power and features an integrated 2-port Ethernet switch for network integration.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHIMA F2 DO 8 01 (F2DO801) contains 8 safety-related relay outputs with potential-free normally open contacts.\u003c\/li\u003e\n\u003cli\u003eIntegrated Ethernet switch with two RJ-45 ports supporting safeethernet communication at 10\/100 Mbit\/s.\u003c\/li\u003e\n\u003cli\u003eRelay outputs feature forcibly guided safety contacts and individual internal 3.15 A fuses.\u003c\/li\u003e\n\u003cli\u003eCompatible with SILworX (OS version 7 and beyond) and ELOP II Factory (OS versions prior to 7).\u003c\/li\u003e\n\u003cli\u003eCompact metal enclosure designed for 35 mm DIN rail mounting with IP20 protection class.\u003c\/li\u003e\n\u003cli\u003eCertified for installation in Ex-Zone 2 hazardous locations.\u003c\/li\u003e\n\u003cli\u003eOnboard diagnostic LED indicators for power supply, processor status, communication, and individual output channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSafety shutdown systems in process automation\u003c\/li\u003e\n\u003cli\u003eRemote I\/O expansion for HIMax and HIMatrix safety controllers\u003c\/li\u003e\n\u003cli\u003eHazardous area control applications requiring Ex-Zone 2 compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDesignation\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eF2 DO 8 01\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O with 8 relay outputs up to 250 VAC \/ 250 VDC, operating temperature 0...+60 degC, for ELOP II Factory programming tool\u003c\/td\u003e\n\u003ctd\u003e98 2200407\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF2 DO 8 01 SILworX\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O with 8 relay outputs up to 250 VAC \/ 250 VDC, operating temperature 0...+60 degC, for SILworX programming tool\u003c\/td\u003e\n\u003ctd\u003e98 2200481\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHIMA Paul Hildebrandt GmbH + Co KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 x RJ-45, 10\/100BaseT (100 Mbit\/s) with integrated switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (-15%...+20%, w_ss \u0026lt;= 15%) from SELV\/PELV power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input\u003c\/td\u003e\n\u003ctd\u003emax. 0.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Fuse\u003c\/td\u003e\n\u003ctd\u003e10 A time-lag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBack-up Battery\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (without plug)\u003c\/td\u003e\n\u003ctd\u003eWidth: 207 mm, Height: 114 mm, Depth: 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Types per Channel\u003c\/td\u003e\n\u003ctd\u003e2 safety relays with forcibly guided contacts, 1 standard relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Relay Outputs\u003c\/td\u003e\n\u003ctd\u003e8 potential-free normally open contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 5 V, \u0026lt;= 250 VAC \/ 250 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 10 mA, \u0026lt;= 3 A (internally fused with 3.15 A, breaking capacity 100 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Switching Capacity (UL)\u003c\/td\u003e\n\u003ctd\u003e250 VAC at 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Switching Capacity (TUV)\u003c\/td\u003e\n\u003ctd\u003emax. 250 VA (cos phi \u0026gt;= 0.5) \/ max. 625 VA (cos phi = 1) at max. 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Switching Capacity (UL)\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 1 A with ohmic load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Switching Capacity (TUV)\u003c\/td\u003e\n\u003ctd\u003eup to 30 VDC: max. 90 W (3.5 A); up to 70 VDC: max. 22 W (0.315 A); up to 127 VDC: max. 25 W (0.25 A); up to 250 VDC: max. 40 W (0.16 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Material\u003c\/td\u003e\n\u003ctd\u003eSilver alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Time\u003c\/td\u003e\n\u003ctd\u003eapprox. 30 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset Time\u003c\/td\u003e\n\u003ctd\u003eapprox. 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBounce Time\u003c\/td\u003e\n\u003ctd\u003eapprox. 15 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 3 x 10^6 switching operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 2.5 x 10^5 switching operations at ohmic full load (\u0026lt;= 0.1 ops\/sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 1\u003c\/td\u003e\n\u003ctd\u003eDO1 Contact 1, terminal A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 2\u003c\/td\u003e\n\u003ctd\u003eDO1 Contact 1, terminal B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 3\u003c\/td\u003e\n\u003ctd\u003eDO2 Contact 2, terminal A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 4\u003c\/td\u003e\n\u003ctd\u003eDO2 Contact 2, terminal B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 5\u003c\/td\u003e\n\u003ctd\u003eDO3 Contact 3, terminal A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 6\u003c\/td\u003e\n\u003ctd\u003eDO3 Contact 3, terminal B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 7\u003c\/td\u003e\n\u003ctd\u003eDO4 Contact 4, terminal A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 8\u003c\/td\u003e\n\u003ctd\u003eDO4 Contact 4, terminal B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 9\u003c\/td\u003e\n\u003ctd\u003eDO5 Contact 5, terminal A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 10\u003c\/td\u003e\n\u003ctd\u003eDO5 Contact 5, terminal B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 11\u003c\/td\u003e\n\u003ctd\u003eDO6 Contact 6, terminal A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 12\u003c\/td\u003e\n\u003ctd\u003eDO6 Contact 6, terminal B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 13\u003c\/td\u003e\n\u003ctd\u003eDO7 Contact 7, terminal A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 14\u003c\/td\u003e\n\u003ctd\u003eDO7 Contact 7, terminal B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 15\u003c\/td\u003e\n\u003ctd\u003eDO8 Contact 8, terminal A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal 16\u003c\/td\u003e\n\u003ctd\u003eDO8 Contact 8, terminal B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module on a standard 35 mm DIN rail within a protective enclosure.\u003c\/li\u003e\n\u003cli\u003eProvide 24 VDC power from a SELV or PELV power supply unit with safe isolation according to IEC 61131-2, protected by an external 10 A time-lag fuse.\u003c\/li\u003e\n\u003cli\u003eFor Ex-Zone 2 installations, mount inside an enclosure achieving at least IP54 protection according to EN 60529 and capable of dissipating heat (power dissipation 18 W to 46 W).\u003c\/li\u003e\n\u003cli\u003eWhen connecting DC switching voltages, fit an external fuse rated for the maximum permissible current in the contact circuit.\u003c\/li\u003e\n\u003cli\u003eUse double or reinforced insulated cabling when switching voltages higher than SELV or PELV.\u003c\/li\u003e\n\u003cli\u003eEnsure electrostatic discharge protective measures are observed, including using an ESD wrist strap during installation or replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE: EMC, ATEX Zone 2 (Directive 94\/9\/EC)\u003c\/li\u003e\n\u003cli\u003eTUV: IEC 61508 Parts 1-7:2000 up to SIL 3, IEC 61511:2004, EN 954-1:1996 up to Cat. 4\u003c\/li\u003e\n\u003cli\u003eTUV ATEX: 94\/9\/EG, EN 1127-1, EN 61508\u003c\/li\u003e\n\u003cli\u003eUL: ANSI\/UL 508, NFPA 70 - Industrial Control Equipment, CSA C22.2 No.142, UL 1998, NFPA 79, IEC 61508\u003c\/li\u003e\n\u003cli\u003eFM Approvals: Class I, DIV 2, Groups A, B, C and D; Class 3600; Class 3611; Class 3810; CSA C22.2 No 142; CSA C22.2 No 213\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":52695389602155,"sku":"F2DO801","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/hima-himatrix-f2do801-safety-remote-output-module-fpvycsrg3z1_3321decd-a63c-4bf0-9d09-6bb412ca889c.jpg?v=1766132993","url":"https:\/\/www.plcprotech.com\/products\/hima-himatrix-f2-do-8-01-safety-related-remote-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}