{"product_id":"honeywell-05701-a-0327-system-57-double-spco-relay-card","title":"Honeywell 05701-A-0327 System 57 Double SPCO Relay Card","description":"\u003cp\u003eHoneywell 05701-A-0327 System 57 Double SPCO Relay Card\u003c\/p\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 05701-A-0327\u003c\/strong\u003e is a plug-in interface and control loop module designed for the \u003cstrong\u003eSystem 57 \/ 5701 Series Control System\u003c\/strong\u003e. This hardware module functions primarily as an electrical bridge providing connections between field-mounted industrial gas sensors and their designated Single Channel Control Cards. By decoupling the continuous gas display and processor logic from physical field wiring, the card secures high loop integrity across individual monitoring nodes.\u003c\/p\u003e\n\u003cp\u003eIn addition to routing standard sensor signaling paths, the module features single-pole change-over (\u003cstrong\u003eSPCO\u003c\/strong\u003e) electromechanical relays that provide voltage-free contact outputs to drive external alarm indicators or protective shutdown systems. These integrated relay contacts are permanently or field-configured to monitor specific hazard indices, continuously operating across discrete thresholds for the \u003cstrong\u003eA1 alarm level\u003c\/strong\u003e, \u003cstrong\u003eA2 alarm level\u003c\/strong\u003e, and local \u003cstrong\u003efault condition\u003c\/strong\u003e paths. The physical layout is optimized for high-density DIN-rail rack assemblies with a dual-chamber separation design providing native attenuation of localized electromagnetic anomalies.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHouses high-reliability single-pole change-over (\u003cstrong\u003eSPCO\u003c\/strong\u003e) relays delivering secure voltage-free contact outputs directly to external field infrastructure.\u003c\/li\u003e\n\u003cli\u003eProcesses individual signal loops for three distinct tracking criteria: \u003cstrong\u003eA1 alarm\u003c\/strong\u003e, \u003cstrong\u003eA2 alarm\u003c\/strong\u003e, and \u003cstrong\u003efault condition\u003c\/strong\u003e states.\u003c\/li\u003e\n\u003cli\u003eIncorporates an integrated ground termination pathway to facilitate clean cable shield drainage directly inside the sub-rack housing.\u003c\/li\u003e\n\u003cli\u003eFormed in a compact 3U Eurocard format factor, permitting seamless slot installation without modifying the existing backplane power bus.\u003c\/li\u003e\n\u003cli\u003eBuilt with independent terminal blocks mapping clearly labeled user references for both front and rear sub-rack access configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed gas monitoring arrays requiring physical contact replication for localized A1 and A2 hazard sirens or warning strobe beams.\u003c\/li\u003e\n\u003cli\u003eInterface termination matrices in industrial marshaling cabinets that bridge analog safety metrics to remote PLC or DCS monitoring systems.\u003c\/li\u003e\n\u003cli\u003eDedicated control loops processing low-voltage field safety signals across oil and gas production environments or water treatment facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05701-A-0327\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble SPCO Relay Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem 57 \/ 5701 Series Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Pole Change-Over (SPCO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Signal Paths\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA1 Alarm, A2 Alarm, Fault Condition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax AC Relay Fusing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5A maximum (when switching mains AC voltages)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e112mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e102mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTB1 - PSU (+)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain External 24V DC Power Supply Unit Positive Termination Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTB1 - PSU (-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain External 24V DC Power Supply Unit Negative Common Reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTB1 - AUX (+)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandby Backup Battery Storage Power Supply Positive Termination Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTB1 - AUX (-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandby Backup Battery Storage Power Supply Negative Common Reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTB1 - GND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-Impedance Dedicated Instrumentation Clean Earth Shield Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eRear Access Connections\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eUser Terminal Reference\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Function\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26 \/ Shield Ground Path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor S Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 \/ Sensor Supply line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor NS Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27 \/ Non-Sink \/ Signal return line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor 01 Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 \/ Sensor 0V reference line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalogue O\/P (+)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29 \/ Isolated Current Loop Output Positive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalogue O\/P (-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 \/ Isolated Current Loop Output Negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Inhibit In\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31 \/ External Channel Inhibit Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Reset In\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34 \/ External Alarm Reset Command Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+24V (Out\/In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 \/ System 24V DC auxiliary line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0V (Out\/In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 \/ System 0V DC auxiliary common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFault NC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 \/ Fault Relay Normally Closed Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFault NO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 \/ Fault Relay Normally Open Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFault COM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 \/ Fault Relay Common Path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA1(1) NC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 \/ A1 Alarm Normally Closed Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA1(1) NO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 \/ A1 Alarm Normally Open Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA1(1) COM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 \/ A1 Alarm Common Path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA2(1) NC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 \/ A2 Alarm Normally Closed Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA2(1) NO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 \/ A2 Alarm Normally Open Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA2(1) COM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 \/ A2 Alarm Common Path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eFront Access Connections\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eUser Terminal Reference\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Function\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0V (Out\/In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 \/ System 0V DC auxiliary common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+24V (Out\/In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 \/ System 24V DC auxiliary line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Reset In\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34 \/ External Alarm Reset Command Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Inhibit In\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 \/ External Channel Inhibit Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalogue O\/P (-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 \/ Isolated Current Loop Output Negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalogue O\/P (+)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31 \/ Isolated Current Loop Output Positive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor 01 Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 \/ Sensor 0V reference line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor NS Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29 \/ Non-Sink \/ Signal return line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 \/ Shield Ground Path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor S Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27 \/ Sensor Supply line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26 \/ Alternative Shield Ground Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 \/ Alternative Shield Ground Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFault NC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 \/ Fault Relay Normally Closed Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFault NO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 \/ Fault Relay Normally Open Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFault COM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 \/ Fault Relay Common Path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA1(1) NC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 \/ A1 Alarm Normally Closed Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA1(1) NO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 \/ A1 Alarm Normally Open Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA1(1) COM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 \/ A1 Alarm Common Path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA2(1) NC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 \/ A2 Alarm Normally Closed Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA2(1) NO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 \/ A2 Alarm Normally Open Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA2(1) COM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 \/ A2 Alarm Common Path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains Switching Safety\u003c\/strong\u003e: When introducing mains AC infrastructure across the relay terminals, verify that the external AC supply lines are strictly restricted with a 5A maximum fuse rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Earth Grounding\u003c\/strong\u003e: A high-integrity safety earth connection must be terminated directly onto the dedicated ground stud terminal of the relay card whenever high-voltage lines are routed to the contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing Separation\u003c\/strong\u003e: Isolate all control relay contact wiring fields from high-sensitivity sensor signal lines to avoid inducing parasitic voltage noise across precision measuring paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-End Shield Termination\u003c\/strong\u003e: For field-mounted gas detectors anchored to local earth studs or steel structures, terminate the cable screen sheath exclusively at one end (either at the sensor body or at the relay interface card) to prevent hazardous ground loop fields.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swap Interlocks\u003c\/strong\u003e: Individual channel control cards can be removed from the front side of the sub-rack without disturbing the active field or relay wiring connected at the rear interface terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow are the contact orientations of the A1 and A2 alarm relays defined?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eThe documented terminal descriptions for normally closed (NC) and normally open (NO) states match the completely de-energized, unpowered condition of the control module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the default operation mode of the onboard FAULT relay circuit?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eThe FAULT relay is hardwired for normally energized operation during normal, non-fault plant conditions, ensuring that a total drop in control loop power triggers a fail-safe system alarm state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the alarm relay actuation modes be altered to fit normally energized logic?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e Yes, the A1 and A2 alarm relays can be individually reconfigured for normally energized or normally de-energised operation by executing setup updates via the central Engineering Interface Software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this interface module accept thicker high-current industrial wires?\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eThe mechanical compression terminals populated on the interface card assembly are rated to accept single-stranded or multi-stranded instrumentation cables up to a maximum cross-sectional area of 2.5mm2.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705770439019,"sku":"05701-A-0327","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/05701-a-0327-dfg3mddemin_0e77e59a-57f9-4ca7-b03a-028bca2220ec.jpg?v=1766659522","url":"https:\/\/www.plcprotech.com\/products\/honeywell-05701-a-0327-system-57-double-spco-relay-card","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}