{"product_id":"honeywell-10102-2-1-11301-fsc-fail-safe-analog-input-module","title":"Honeywell 10102\/2\/1 11301 FSC Fail-Safe Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 10102\/2\/1\u003c\/strong\u003e is a 4-channel fail-safe analog input module designed for safety-critical application in Honeywell Fail Safe Control (FSC) systems. Featuring a native 0-2 Vdc input range, the inputs share a common 0 V connection and are galvanically isolated from the internal 24 Vdc and 5 Vdc supply rails.\u003c\/p\u003e\n\u003cp\u003eThe module supports both active mode (supplying individual 26 Vdc short-circuit protected loop power for field transmitters) and passive mode (utilizing external transmitter power). Due to its high input impedance, two 10102\/2\/1 modules can be wired in parallel for enhanced redundancy. Every input channel requires an external analog input converter module (10102\/A\/x series), making this module strictly compatible with I\/O backplanes in the FSC rack.\u003c\/p\u003e\n\u003cp\u003eIntegrated self-diagnostics continuously monitor process safety times by testing absolute accuracy, full-range conversion integrity, inter-channel crosstalk, and internal reference voltages generated via an onboard D\/A converter.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 Galvanically Isolated Input Channels:\u003c\/strong\u003e Standard 0-2 Vdc direct input range, isolated from internal 5 Vdc and 24 Vdc electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive\/Passive Power Support:\u003c\/strong\u003e Provides active 26 Vdc power output for loop-powered transmitters, or accepts passive input signals from externally powered devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel Capability:\u003c\/strong\u003e High input impedance allows parallel wiring of two 10102\/2\/1 modules to double system signal distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Self-Testing:\u003c\/strong\u003e Scans inputs, internal supplies, and 26 Vdc outputs within configured process safety time windows, including input filter leakage testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Enhanced Variant:\u003c\/strong\u003e Module suffix 11301 features upgraded electromagnetic compatibility (EMC) protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-Bit Resolution A\/D Conversion:\u003c\/strong\u003e High-accuracy digital conversion with \u0026lt;= 0.75% total inaccuracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral \u0026amp; Power Requirements\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety Management Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType Number\u003c\/td\u003e\n\u003ctd\u003e10102\/2\/1 (11301* with enhanced EMC behavior)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE, TÜV, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Compatibility\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 3.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpace Requirements\u003c\/td\u003e\n\u003ctd\u003e4 TE, 3 HE (= 4 HP, 3U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (5 Vdc)\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (24 Vdc)\u003c\/td\u003e\n\u003ctd\u003e175 mA + 25 mA per active input channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eInput Performance\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0-2 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 100 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Max. Input Signal\u003c\/td\u003e\n\u003ctd\u003e+\/- 5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Converter\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInaccuracy\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 0.75%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Powering\u003c\/td\u003e\n\u003ctd\u003e26 Vdc (+\/- 1 V for 0.2 mA \u0026lt; I \u0026lt; 20 mA), short-circuit protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Current Limit\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 21 mA (solid state)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eMechanical Key Coding\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCode Pin Locations\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Connector Holes\u003c\/td\u003e\n\u003ctd\u003eA5, C17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Connector Large Pins\u003c\/td\u003e\n\u003ctd\u003eA5, C17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFSC Analog Input Signal Matching (10102\/A\/x Compatibility)\u003c\/h3\u003e\n\u003cp\u003eTo interface standard field instrumentation, the 10102\/2\/1 must be paired with the appropriate \u003cstrong\u003e10102\/A\/x\u003c\/strong\u003e converter module as detailed below:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eField Signal Range\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eModule Combination\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0(4)-20 mA\u003c\/td\u003e\n\u003ctd\u003eInternal power (Active)\u003c\/td\u003e\n\u003ctd\u003e10102\/2\/1 + 10102\/A\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0(4)-20 mA\u003c\/td\u003e\n\u003ctd\u003eExternal power (Passive)\u003c\/td\u003e\n\u003ctd\u003e10102\/2\/1 + 10102\/A\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0(1)-5 V\u003c\/td\u003e\n\u003ctd\u003eExternal power\u003c\/td\u003e\n\u003ctd\u003e10102\/2\/1 + 10102\/A\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0(2)-10 V\u003c\/td\u003e\n\u003ctd\u003eExternal power\u003c\/td\u003e\n\u003ctd\u003e10102\/2\/1 + 10102\/A\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop-monitored Digital Input\u003c\/td\u003e\n\u003ctd\u003eDirect \/ Field Power\u003c\/td\u003e\n\u003ctd\u003e10102\/2\/1 + 10102\/A\/5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003ci\u003eNote: Non-standard signals (e.g., Thermocouples, PT-100 RTDs) must be pre-converted into standard voltage or current loops prior to connecting to the 10102\/A\/x adapters.\u003c\/i\u003e\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Safety Inspection:\u003c\/strong\u003e Verify the physical integrity of the Eurocard housing, backplane pin connectors, and key-coding mechanism. Ensure system power down or follow plant-specific hot-swap safety protocols before inserting the module into an active rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Keying Alignment:\u003c\/strong\u003e Confirm the backplane slot is key-coded to match the module's key pattern (A5 C17 for model 10102\/2\/1). Do not force the card if resistance is met, as bent keying pins must be replaced rather than re-bent.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Insertion:\u003c\/strong\u003e Carefully align the module card edges with the top and bottom guide rails of the designated FSC I\/O rack. Slide the module firmly into place until the rear backplane connectors seat completely. Tighten front panel retaining screws to secure grounding and mechanical engagement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring and Converter Module Setup:\u003c\/strong\u003e Verify signal conditioning wiring via the appropriate Field Termination Assembly (FTA) or external resistor conversion network (e.g., converting 4-20 mA or 0-10 V inputs into the required module voltage level). Ensure shielded twisted-pair cabling is grounded at one end to prevent ground loop interference.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration and Commissioning\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Software Configuration:\u003c\/strong\u003e Open the FSC user station software and assign the module to its precise rack and slot position as defined in the project hardware layout. Confirm software revision compatibility is set to version 3.00 or higher.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Calibration and Loop Verification:\u003c\/strong\u003e Inject calibrated reference signals (e.g., 4 mA, 12 mA, and 20 mA via a loop calibrator) at the FTA terminals. Check the software engineering units and diagnostic display to confirm analog-to-digital conversion accuracy across all 4 channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Verification:\u003c\/strong\u003e Monitor front panel status LEDs and the Diagnostic and Battery Module (DBM) system status to ensure no channel fault, open-loop condition, or backplane communication error is reported.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN V 19250 \/ DIN V 0801:\u003c\/strong\u003e Certified for safety-critical applications up to Requirement Class AK 8.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Compliance:\u003c\/strong\u003e Conforms to European EMC Directive (89\/336\/EEC) and Low Voltage Directive (73\/23\/EEC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Safety Standards:\u003c\/strong\u003e Complies with EN 61131-2 (Programmable Controllers) and UL 508 \/ UL 1998 (Safety-Related Software and Control Equipment).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing:\u003c\/strong\u003e Tested to DIN IEC 68 Part 2 standards for cold, dry heat, damp heat, shock, and sinusoidal vibration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52679385710955,"sku":"10102\/2\/1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/10102-2-1_001_1200x1200_b4011105-549c-4397-9046-ad6de210d7d5.jpg?v=1786768569","url":"https:\/\/www.plcprotech.com\/products\/honeywell-10102-2-1-11301-fsc-fail-safe-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}