{"product_id":"honeywell-10106-2-1-fail-safe-line-monitored-digital-input-module","title":"Honeywell 10106\/2\/1 Fail-Safe Line-Monitored Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 10106\/2\/1\u003c\/strong\u003e is a 16-channel fail-safe digital input module for Honeywell FSC systems. It is designed for \u003cstrong\u003e24\/48 VDC NAMUR field inputs\u003c\/strong\u003e with line monitoring and earth-fault supervision.\u003c\/p\u003e\n\u003cp\u003eThe module uses NAMUR input characteristics and monitors field circuits rather than only reading ON\/OFF states. This makes the 10106\/2\/1 suitable where input wiring faults must be distinguished from normal process status. Honeywell FSC documentation identifies it as a \u003cstrong\u003efail-safe line-monitored digital input module with earth fault monitor\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 digital input channels\u003c\/li\u003e\n\u003cli\u003eFail-safe input processing\u003c\/li\u003e\n\u003cli\u003eNAMUR input interface\u003c\/li\u003e\n\u003cli\u003e24\/48 VDC field input application\u003c\/li\u003e\n\u003cli\u003eLine-monitored input circuits\u003c\/li\u003e\n\u003cli\u003eEarth-fault monitoring\u003c\/li\u003e\n\u003cli\u003e1.4 to 1.9 mA switching level\u003c\/li\u003e\n\u003cli\u003e0.2 mA hysteresis\u003c\/li\u003e\n\u003cli\u003eMaximum 50 Ohm field-wire resistance\u003c\/li\u003e\n\u003cli\u003eShort-circuit-protected 8 V loop supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSafety-related digital input acquisition\u003c\/li\u003e\n\u003cli\u003eNAMUR sensor and contact monitoring\u003c\/li\u003e\n\u003cli\u003eField wiring supervision\u003c\/li\u003e\n\u003cli\u003eESD and interlock input processing\u003c\/li\u003e\n\u003cli\u003eHoneywell FSC I\/O replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e10106\/2\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFail-Safe Line-Monitored Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eHoneywell FSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eNAMUR, DIN 19234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Input Application\u003c\/td\u003e\n\u003ctd\u003e24\/48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch Level\u003c\/td\u003e\n\u003ctd\u003e1.4 to 1.9 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHysteresis\u003c\/td\u003e\n\u003ctd\u003e0.2 mA +\/-0.05 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wire Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ohm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8 V Loop Supply\u003c\/td\u003e\n\u003ctd\u003e7.9 to 8.7 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Supply Current\u003c\/td\u003e\n\u003ctd\u003e170 mA, short-circuit protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 x 14 x 19.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003ePower Requirements\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eCurrent\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003ctd\u003e160 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003ctd\u003e110 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEarth-Fault Monitoring\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth Connection Monitor\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003eTypically 0.5 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance Range\u003c\/td\u003e\n\u003ctd\u003e-40 V \u0026lt; U \u0026lt; +40 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Current\u003c\/td\u003e\n\u003ctd\u003eTypically 0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003eTypically 0.5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Fault Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eReplacement Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMatch the complete \u003cstrong\u003e10106\/2\/1\u003c\/strong\u003e model number.\u003c\/li\u003e\n\u003cli\u003eConfirm the existing field circuits use the NAMUR configuration.\u003c\/li\u003e\n\u003cli\u003ePreserve channel wiring and line-monitoring arrangements during replacement.\u003c\/li\u003e\n\u003cli\u003eModules with suffix code 22100 have a documented restriction when used with 10106\/A\/2 converter modules.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668003287403,"sku":"10106\/2\/1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-10106-2-1-control-module-hk4fas2ratd_f986d423-e91f-4903-bed3-91206dde8e73.jpg?v=1765505024","url":"https:\/\/www.plcprotech.com\/products\/honeywell-10106-2-1-fail-safe-line-monitored-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}