{"product_id":"honeywell-51309206-125-universal-xpm-charger-circuit-board-rev-b","title":"Honeywell 51309206-125 Universal XPM Charger Circuit Board Rev B","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51309206-125 Rev B\u003c\/strong\u003e is a \u003cstrong\u003eUniversal XPM Charger Circuit Board\u003c\/strong\u003e designed for process control and DCS power subsystem management within Honeywell industrial systems. Functioning as a dedicated battery charger and power regulation assembly, this module manages power delivery, battery charging cycles, and status monitoring for Process Manager \/ Extended Process Manager (XPM) field enclosures and control racks.\u003c\/p\u003e\n\u003cp\u003eBuilt on a high-reliability industrial printed circuit board assembly (Assembly No. \u003cstrong\u003e51309206-125\u003c\/strong\u003e), the card incorporates integrated voltage regulation, current limiting circuitry, onboard fuse protection, and signaling relays. Interface connection to the backplane or system chassis is established via an onboard multi-pin DIN 41612 standard connector (DIN 48CPC connector marked J1).\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUniversal XPM charger board architecture for Honeywell process control subsystem power management\u003c\/li\u003e\n\u003cli\u003eIntegrated power switching and linear\/switching voltage regulation components with heatsink thermal dissipation\u003c\/li\u003e\n\u003cli\u003eOnboard fuse holder (F1) providing hardware-level overcurrent protection\u003c\/li\u003e\n\u003cli\u003eSolid-state logic ICs and onboard electromechanical relay for battery status switching and alarm outputs\u003c\/li\u003e\n\u003cli\u003eStandard DIN 41612 (48-pin) connector interface (J1) for direct backplane insertion and signal routing\u003c\/li\u003e\n\u003cli\u003eMulti-stage resistor-capacitor filtering network for stable DC output conditioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBattery charging and power backup regulation in Honeywell TDC 3000 \/ Process Manager systems\u003c\/li\u003e\n\u003cli\u003ePower distribution and monitoring inside Extended Process Manager (XPM) cabinets\u003c\/li\u003e\n\u003cli\u003eReplacement circuit assembly for industrial DCS power supply units and battery backup modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51309206-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRevision\u003c\/td\u003e\n\u003ctd\u003eRev B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Description\u003c\/td\u003e\n\u003ctd\u003eUniversal XPM Charger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePrinted Circuit Board \/ Power Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Process Manager \/ XPM Subsystems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Connector Interface\u003c\/td\u003e\n\u003ctd\u003eDIN 41612 48-Pin Male Connector (J1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Components\u003c\/td\u003e\n\u003ctd\u003eOnboard Fuse (F1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ1 Connector\u003c\/td\u003e\n\u003ctd\u003e48-Pin DIN 41612 backplane edge connector for DC power input, charge output, and system status signaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm system DC power is isolated and battery leads are safely disconnected before removing or installing the board.\u003c\/li\u003e\n\u003cli\u003eObserve proper ESD (electrostatic discharge) safety precautions, including grounding wrist straps, when handling the circuit assembly.\u003c\/li\u003e\n\u003cli\u003eInspect the board visually for physical damage, blown fuses, or loose components prior to mounting.\u003c\/li\u003e\n\u003cli\u003eAlign the board carefully with the chassis card guides and push firmly until the J1 DIN connector seats completely into the backplane socket.\u003c\/li\u003e\n\u003cli\u003eRe-engage rack mechanical locks or retention screws before restoring system power and battery connections.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e Fully disconnect primary AC\/DC input power and battery backup lines before swapping the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Inspection:\u003c\/strong\u003e Verify that the replacement unit has the correct fuse rating installed in position F1 before power-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePost-Replacement Checks:\u003c\/strong\u003e Upon restoring power, measure charge output voltage across battery terminals to verify proper charger regulation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667760476523,"sku":"51309206-125","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/51309206-125_001_1200x1200_5444eb07-6338-4634-bc54-18517c33a2c8.jpg?v=1787661136","url":"https:\/\/www.plcprotech.com\/products\/honeywell-51309206-125-universal-xpm-charger-circuit-board-rev-b","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}