{"product_id":"honeywell-621-2150r-logic-manager-digital-output-module","title":"Honeywell 621-2150R Logic Manager Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 621-2150R\u003c\/strong\u003e is a digital output module designed for high-speed switching of AC load devices in Logic Manager systems on the Universal Control Network (UCN). Operating within a 90-140 Vac range with a 115 Vac nominal voltage, this module provides 16 AC output channels that activate at zero crossing to reduce electrical noise during operation. The \u003cstrong\u003e621-2150R\u003c\/strong\u003e features single-common point distribution across all 16 points, 2 A maximum current capacity per circuit, and individual 3 A slow-blow fuse protection for connected industrial loads.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures 16 digital output channels with zero-crossing activation\u003c\/li\u003e\n\u003cli\u003eConfigured with 16 points per single common line\u003c\/li\u003e\n\u003cli\u003eDelivers up to 2 A maximum current per circuit and 12 A total per module\u003c\/li\u003e\n\u003cli\u003eProvides individual circuit protection via 3 A slow-blow fuses\u003c\/li\u003e\n\u003cli\u003eWithstands nonrepetitive surge currents up to 15 A for 2 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC load switching\u003c\/li\u003e\n\u003cli\u003eSolenoid valve control\u003c\/li\u003e\n\u003cli\u003eMotor starter activation\u003c\/li\u003e\n\u003cli\u003eRelay coil control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 Output On at zero crossing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoints Per Common\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90-140 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A per circuit, 12 A per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A, 2 cycle (nonrepetitive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff-State Leakage Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e= 5 mA (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-State Voltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e= 2 Vac at 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFusing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 per circuit, 3 A slo blow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Current (+5 Vdc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145 mA plus 24 mA for each Energized output, 529 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEEE 518 Signal Level Wiring Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDATA 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm that the AC line supply power stays within the required 90-140 Vac operating range.\u003c\/li\u003e\n\u003cli\u003eVerify that total load current across all 16 channels does not exceed the module limit of 12 A.\u003c\/li\u003e\n\u003cli\u003eDisconnect main field power prior to inspecting or replacing the 3 A slow-blow individual circuit fuses.\u003c\/li\u003e\n\u003cli\u003eComply with IEEE 518 DATA 3 wiring practices for proper cable routing and noise isolation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705557709163,"sku":"621-2150R","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/621-2150R_004_1200x1200_088113ba-8885-46b1-ba1d-5d8345b55022.jpg?v=1786010088","url":"https:\/\/www.plcprotech.com\/products\/honeywell-621-2150r-logic-manager-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}