{"product_id":"honeywell-8c-ip0102-51454362-275-series-8-profibus-gateway-module","title":"Honeywell 8C-IP0102 51454362-27 Experion LX Series 8 PROFIBUS Gateway Module Coated","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-IP0102\u003c\/strong\u003e (Part Number: \u003cstrong\u003e51454362-275\u003c\/strong\u003e) is a conformally coated PROFIBUS Gateway Module (PGM) engineered for the Experion LX Series 8 Distributed Control System (DCS) platform. Supplied complete with its dedicated \u003cstrong\u003e8C-TPOXA1\u003c\/strong\u003e Input Output Termination Assembly (IOTA) base, this gateway system serves as an industrial communication interface connecting PROFIBUS DP field networks directly into the Series 8 control architecture. The module handles high-speed protocol translation and data routing between field instrumentation, motor control centers (MCC), variable frequency drives (VFD), or remote I\/O subsystems and the higher-level controller network.\u003c\/p\u003e\n\u003cp\u003eDesigned for demanding process environments, both the \u003cstrong\u003e8C-IP0102\u003c\/strong\u003e gateway module and the \u003cstrong\u003e8C-TPOXA1\u003c\/strong\u003e IOTA base feature factory-applied conformal coating to protect internal electronic components against airborne contaminants, corrosive atmospheres, and moisture. The complete assembly mounts securely inside standard control enclosures, drawing regulated 24 VDC system power via the cabinet power distribution bus while providing redundant Fault Tolerant Ethernet (FTE) interfaces for high-availability control-level networking.\u003c\/p\u003e\n\u003cp\u003eOperating as a unified communication gateway, the \u003cstrong\u003eHoneywell 8C-IP0102\u003c\/strong\u003e set enables bi-directional process data transfer, device status reporting, and fieldbus diagnostics. Integrated status indicators on the module faceplate allow maintenance personnel to quickly verify power status, operational modes, and communication activity during standard operation or field troubleshooting.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete hardware set combining the \u003cstrong\u003e8C-IP0102\u003c\/strong\u003e module and matching \u003ca href=\"\/products\/honeywell-8c-tpoxa1-51307153-175-experion-series-8-profibus-gateway-iota-coated\"\u003e8C-TPOXA1\u003c\/a\u003e IOTA base.\u003c\/li\u003e\n\u003cli\u003eFactory-applied conformal coating across all board assemblies for harsh environment protection.\u003c\/li\u003e\n\u003cli\u003eDesigned specifically for seamless integration into Experion LX Series 8 DCS architectures.\u003c\/li\u003e\n\u003cli\u003eDedicated PROFIBUS DP gateway interface supporting high-speed fieldbus device networks.\u003c\/li\u003e\n\u003cli\u003eDual RJ-45 Fault Tolerant Ethernet (FTE) ports on the IOTA base for high-availability communication.\u003c\/li\u003e\n\u003cli\u003eIntegrated front faceplate LED status indicators for power, CPU status, and bus network diagnostics.\u003c\/li\u003e\n\u003cli\u003eHot-swappable module design enabling physical unit replacement without disturbing field or network wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInterfacing PROFIBUS DP motor control centers (MCC) and variable frequency drives (VFD) to Series 8 control strategies.\u003c\/li\u003e\n\u003cli\u003eConnecting third-party smart field transmitters, gas chromatographs, and discrete I\/O racks to Experion LX.\u003c\/li\u003e\n\u003cli\u003eIntegrating complex skid-based package automation into unified DCS supervisory control systems.\u003c\/li\u003e\n\u003cli\u003eHeavy industrial and offshore installations requiring conformally coated electronics against corrosive gases.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGateway Module Part Number\u003c\/td\u003e\n\u003ctd\u003e51454362-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGateway Module Model\u003c\/td\u003e\n\u003ctd\u003e8C-IP0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatching IOTA Base Part Number\u003c\/td\u003e\n\u003ctd\u003e8C-TPOXA1 (\u003ca href=\"\/products\/honeywell-8c-tpoxa1-51307153-175-experion-series-8-profibus-gateway-iota-coated\" title=\"8C-TPOXA1 51307153-175 Gateway IOTA\"\u003eLearn more\u003c\/a\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eExperion LX Series 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS Gateway Module Set (PGM + IOTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Protection\u003c\/td\u003e\n\u003ctd\u003eConformal Coated (Module \u0026amp; Base)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Current\u003c\/td\u003e\n\u003ctd\u003e430 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +60 degC (32 degF to +140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration (Sinusoidal)\u003c\/td\u003e\n\u003ctd\u003e10-57 Hz: 0.075 mm displacement; 57-150 Hz: 1 G acceleration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e15 G peak for 11 ms duration (across 3 axes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Accessories Included\u003c\/td\u003e\n\u003ctd\u003e8C-TPOXA1 PROFIBUS Gateway IOTA Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that the cabinet environment satisfies operating conditions: ambient temperature between 0 degC and +60 degC and relative humidity between 5% and 95% non-condensing.\u003c\/li\u003e\n\u003cli\u003eSecurely mount the \u003cstrong\u003e8C-TPOXA1\u003c\/strong\u003e IOTA base onto the cabinet DIN rail or mounting channel.\u003c\/li\u003e\n\u003cli\u003eVerify cabinet grounding is properly bonded using minimum #8 AWG solid copper wire connected from the IOTA ground lug to the main AC safety ground bar.\u003c\/li\u003e\n\u003cli\u003eAlign the \u003cstrong\u003e8C-IP0102\u003c\/strong\u003e circuit board edge connectors with the mating connector socket on the \u003cstrong\u003e8C-TPOXA1\u003c\/strong\u003e IOTA base.\u003c\/li\u003e\n\u003cli\u003ePush the module firmly onto the IOTA connector until fully seated.\u003c\/li\u003e\n\u003cli\u003eHand-tighten the retention screws on each side of the module cover to secure the physical assembly to the IOTA base.\u003c\/li\u003e\n\u003cli\u003eTighten the front plastic screw on the module faceplate using a #2 Phillips screwdriver without over-torquing.\u003c\/li\u003e\n\u003cli\u003eConnect yellow FTE-A Cat5 cable to FTEA connector and green FTE-B Cat5 cable to FTEB connector on the IOTA board.\u003c\/li\u003e\n\u003cli\u003eWire the shielded DB9\/terminal PROFIBUS network cables to the corresponding PBLink connectors on the IOTA base.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \/ Commissioning \/ Replacement\u003c\/h3\u003e\n\u003ch4\u003eConfiguration \u0026amp; Commissioning\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSet the rotary FTE Device Index switches (1 to 999) on the \u003cstrong\u003e8C-TPOXA1\u003c\/strong\u003e IOTA base to match the assigned node address in Honeywell Control Builder.\u003c\/li\u003e\n\u003cli\u003eApply 24 VDC system power; observe that the module boots into an ALIVE or NODB (No Database) operational state.\u003c\/li\u003e\n\u003cli\u003eDownload the appropriate firmware version matching the running system software baseline via Control Builder.\u003c\/li\u003e\n\u003cli\u003ePerform a \"Load with Contents\" operation from Control Builder to transfer network configurations, slave device maps, and control strategies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eReplacement Recommendations\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-Process Requirement:\u003c\/strong\u003e Ensure the associated control loop or process segment is brought to a safe offline state prior to module maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Removal:\u003c\/strong\u003e Loosen the two side cover screws and front faceplate plastic screw. Gently pull the module straight out from the \u003cstrong\u003e8C-TPOXA1\u003c\/strong\u003e IOTA base socket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Installation:\u003c\/strong\u003e Insert the replacement \u003cstrong\u003e8C-IP0102\u003c\/strong\u003e module onto the existing IOTA base, securing all side screws and front plastic screw.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRestoration:\u003c\/strong\u003e Once power is verified and the module reaches the ALIVE or NODB state, reload matching firmware and execute a \"Load with Contents\" from Control Builder.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility (EMC):\u003c\/strong\u003e EN 61326-1:2006, IEC 61326-1:2005\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Voltage Directive (LVD) \/ Safety:\u003c\/strong\u003e EN 61010-1:2010\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirectives:\u003c\/strong\u003e 2004\/108\/EC (EMC Directive), 2006\/95\/EC (Low Voltage Directive)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667990606187,"sku":"8C-IP0102 51454362-275","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-ip0102-51454362-275-profibus-gateway-module-dptoxvneva1_1d3744bb-b018-4001-a640-40c222d36f46.jpg?v=1765504892","url":"https:\/\/www.plcprotech.com\/products\/honeywell-8c-ip0102-51454362-275-series-8-profibus-gateway-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}