{"product_id":"honeywell-8c-pain01-51454356-175-series-8-coated-high-level-analog-input-module","title":"Honeywell 8C-PAIN01 51454356-175 Series 8 Coated High-Level Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-PAIN01\u003c\/strong\u003e (Part Number \u003cstrong\u003e51454356-175\u003c\/strong\u003e) is a conformally coated, 16-channel High-Level Analog Input Module (IOM) designed for high-density analog signal processing within the Honeywell Experion Process Knowledge System (PKS) and PlantCruise by Experion Series 8 I\/O architecture. Operating under the control of the C300 Controller, the module interfaces directly with 4-20 mA DC current signals from 2-wire field transmitters or self-powered process instruments.\u003c\/p\u003e\n\u003cp\u003eArchitecturally, the \u003cstrong\u003eHoneywell 8C-PAIN01\u003c\/strong\u003e mounts directly onto a Series 8 Input Output Termination Assembly (IOTA) via physical blind-mating connectors, completely eliminating the need for a separate electronic chassis or external marshalling racks. Its physical form factor features the signature Series 8 tilted housing layout, which optimizes thermal dissipation performance and allows high cabinet packing density without compromise to system availability.\u003c\/p\u003e\n\u003cp\u003eEngineered with conformal coating (designated by the 8C prefix), the \u003cstrong\u003eHoneywell 8C-PAIN01\u003c\/strong\u003e internal circuitry is protected against atmospheric moisture, conductive dust, airborne chemical contaminants, and temperature extremes. The module includes integrated, individually protected current-limiting power distribution to feed field transmitters directly from the IOTA. This built-in signal conditioning provides Class 1, Division 2 non-incendive field power without requiring external user-supplied field power supplies or inline field fuses.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Single-Ended Input Channels:\u003c\/strong\u003e Accepts standard 4-20 mA analog signals across a 200 ohm sense resistor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16-Bit A\/D Resolution:\u003c\/strong\u003e High-resolution analog-to-digital conversion provides precise input sampling for process control variables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Loop Execution:\u003c\/strong\u003e Features a 50 ms input scan rate across all channels for rapid process variable updates to the C300 controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformally Coated Assembly:\u003c\/strong\u003e Provides physical circuit board protection against harsh environmental contaminants, humidity, and chemical exposure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Incendive Transmitter Power:\u003c\/strong\u003e Delivers integrated, current-limited transmitter field power supporting Class 1, Div 2 hazardous locations without external marshalling or fuses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant \u0026amp; Non-Redundant Configurations:\u003c\/strong\u003e Plugs onto the 6-inch non-redundant IOTA (8C-TAIX51) or the 12-inch redundant IOTA (8C-TAIX61) where dual IOMs reside on a single assembly without external switchover cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Heat Management:\u003c\/strong\u003e Tilted vertical module design promotes cabinet air circulation and heat dissipation in high-density installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Variable Monitoring:\u003c\/strong\u003e Continuous current loop measurement from pressure, flow, level, and temperature transmitters in continuous or batch process environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDCS Control Loop Inputs:\u003c\/strong\u003e Direct process variable (PV) feedback to the C300 Controller for PID control strategies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Field Interfacing:\u003c\/strong\u003e Powering and acquiring 4-20 mA current loops in Class 1, Division 2 process plant environments using non-incendive circuit topology.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-PAIN01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51454356-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries \/ Platform\u003c\/td\u003e\n\u003ctd\u003eSeries 8 I\/O \/ PlantCruise by Experion \/ Experion PKS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Analog Input Module (Coated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 Channels (Single-Ended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC (2-wire or self-powered transmitters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Converter Resolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance \/ Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA through 200 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Scan Rate\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Accuracy (@ CMV = 0 V)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e+\/-0.075% of full-scale (23.5 degC +\/- 2 degC)\u003c\/p\u003e\n\u003cp\u003e+\/-0.15% of full-scale (0 to 60 degC)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Non-Damaging Input Voltage\u003c\/td\u003e\n\u003ctd\u003e+\/-30 VDC (any input referenced to common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Rejection Ratio (NMRR)\u003c\/td\u003e\n\u003ctd\u003e19 dB at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Filter Response\u003c\/td\u003e\n\u003ctd\u003eSingle-pole RC, -3 dB @ 6.5 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Channel Crosstalk\u003c\/td\u003e\n\u003ctd\u003e-60 dB (DC to 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power Conditioning\u003c\/td\u003e\n\u003ctd\u003eIndividually protected current-limiting circuits (Class 1, Div 2 non-incendive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Non-Redundant IOTA\u003c\/td\u003e\n\u003ctd\u003e8C-TAIX51 (Coated, 6-inch \/ 152 mm width)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Redundant IOTA\u003c\/td\u003e\n\u003ctd\u003e8C-TAIX61 (Coated, 12-inch \/ 304 mm width)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Verification:\u003c\/strong\u003e Confirm that the mounting environment matches the module specifications. Though the \u003cstrong\u003eHoneywell 8C-PAIN01\u003c\/strong\u003e features conformal coating, cabinet temperature should remain within 0 to 60 degC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIOTA Installation:\u003c\/strong\u003e Mount the compatible IOTA assembly (8C-TAIX51 for single, 8C-TAIX61 for redundant configurations) to the cabinet mounting channel. Securely fasten the bushed 24 VDC power connections to the backplane carrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Termination:\u003c\/strong\u003e Land field instrument wiring at the two-level detachable screw terminals on the IOTA. Ensure signal polarity matches 2-wire powered or self-powered loop configurations (wiring accepts up to 12 AWG \/ 2.5 mm2 stranded wire).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Align the rear connector pins of the \u003cstrong\u003e8C-PAIN01\u003c\/strong\u003e module with the dedicated IOM slot on the IOTA. Press firmly until the mechanical latches seat completely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Assembly Setup:\u003c\/strong\u003e If configuring redundant analog inputs on an 8C-TAIX61 IOTA, insert two identical \u003cstrong\u003e8C-PAIN01\u003c\/strong\u003e modules into the primary and secondary slots. Redundancy control is handled directly by the IOTA hardware backplane without external interconnect cables.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration Recommendations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Assignment:\u003c\/strong\u003e Assign the \u003cstrong\u003e8C-PAIN01\u003c\/strong\u003e module to its designated I\/O Link channel under the host C300 Controller configuration tree in the engineering environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Parameterization:\u003c\/strong\u003e Define the input signal range, PV scaling limits, filter constant, and failure state handling for each of the 16 analog channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Budgeting Check:\u003c\/strong\u003e Verify total current consumption from 2-wire field loops to ensure the IOTA 24 VDC supply bus remains well within operational margins during normal field instrument draw.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning \u0026amp; Diagnostic Verification:\u003c\/strong\u003e Prior to placing loops into auto control, inspect the Series 8 status indicator on the module front panel to confirm green operational health and verify individual process values at the engineering station.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667755397483,"sku":"8C-PAIN01 51454356-175","price":1800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8C-PAIN01-51454356-175_001_1200x1200_6ea21ba4-56a0-45b7-a951-3307a52b0c70.jpg?v=1786802593","url":"https:\/\/www.plcprotech.com\/products\/honeywell-8c-pain01-51454356-175-series-8-coated-high-level-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}