{"product_id":"honeywell-8c-tpoxa1-51307153-175-experion-series-8-profibus-gateway-iota-coated","title":"Honeywell 8C-TPOXA1 51307153-175 Experion Series 8 PROFIBUS Gateway IOTA, Coated","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-TPOXA1\u003c\/strong\u003e (Part Number \u003cstrong\u003e51307153-175\u003c\/strong\u003e) is a conformal coated Input\/Output Termination Assembly (IOTA) designed specifically for the Honeywell \u003cstrong\u003eExperion LX Series 8\u003c\/strong\u003e Distributed Control System (DCS) platform. It serves as the physical mounting and wiring interface for the \u003cstrong\u003eHoneywell 8C-IP0102 PROFIBUS Gateway Module (PGM)\u003c\/strong\u003e, enabling fieldbus communication links between field instrumentation and the controller system.\u003c\/p\u003e\n\u003cp\u003eThis IOTA functions as the vital connection point for external field communication cables, power distribution, and system-level interface routing. Built with factory conformal coating, the \u003cstrong\u003e8C-TPOXA1\u003c\/strong\u003e is engineered to withstand harsh industrial processing environments, preventing board-level contamination and corrosion.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Gateway Interface:\u003c\/strong\u003e Designed specifically to host the 8C-IP0102 PROFIBUS Gateway Module within the Experion Series 8 architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating Protection:\u003c\/strong\u003e Coated circuit board construction provides enhanced resilience against industrial airborne pollutants and moisture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Connectivity:\u003c\/strong\u003e Features dual FTE-A and FTE-B Ethernet link RJ-45 ports along with PBLink network interface terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddressing Capability:\u003c\/strong\u003e Incorporates three rotary FTE Device Index switches directly on the assembly for hardware node identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Bus Isolation:\u003c\/strong\u003e Features grounded mounting interface hardware connecting to the system COM bus bar for proper ground integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Control Fieldbus Integration:\u003c\/strong\u003e Hosts PROFIBUS gateway modules connecting smart instrumentation to Experion Series 8 DCS controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosive Processing Environments:\u003c\/strong\u003e Ideal for installation in chemical, oil and gas, or manufacturing facilities requiring conformal coated control hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Network Subsystems:\u003c\/strong\u003e Interfacing field devices with high-availability control network topologies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-TPOXA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51307153-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS Gateway IOTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eExperion LX Series 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eConformal Coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current Rating\u003c\/td\u003e\n\u003ctd\u003e20 A (Header board subsystem)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e10–57 Hz (0.075 mm displacement), 57–150 Hz (1 G load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Shock\u003c\/td\u003e\n\u003ctd\u003e15 G in 3 axes (11 ms duration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface \/ Connector\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFTE-A (RJ-45)\u003c\/td\u003e\n\u003ctd\u003ePrimary Fault Tolerant Ethernet network link connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFTE-B (RJ-45)\u003c\/td\u003e\n\u003ctd\u003eSecondary Fault Tolerant Ethernet network link connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePBLink Ports\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS network cable terminal connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Index Switches\u003c\/td\u003e\n\u003ctd\u003eThree rotary switches for setting FTE hardware network node address\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem COM Ground\u003c\/td\u003e\n\u003ctd\u003eGround connection interface to cabinet COM bus bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that the system power supply is isolated or the system is off-process before mounting.\u003c\/li\u003e\n\u003cli\u003eConfirm the IOTA hardware part number and ensure the conformal coating matches installation requirements.\u003c\/li\u003e\n\u003cli\u003eMount the IOTA onto the cabinet channel rail using the dedicated screws, washers, and spacers.\u003c\/li\u003e\n\u003cli\u003eTighten the grounding screw on the right side of the IOTA to secure connection to the cabinet COM bus bar.\u003c\/li\u003e\n\u003cli\u003eEnsure the four main mounting screws are tightened uniformly without causing board distortion.\u003c\/li\u003e\n\u003cli\u003eConnect the yellow Cat5 cable to the FTE-A connector and green Cat5 cable to the FTE-B connector.\u003c\/li\u003e\n\u003cli\u003eTerminate PBLink fieldbus cables to their designated connector points.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration and Replacement Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Verification:\u003c\/strong\u003e Set the three rotary FTE Device Index switches to match the exact node address of the original unit prior to powering up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Seating:\u003c\/strong\u003e When installing the 8C-IP0102 gateway module onto the IOTA, ensure board edge connectors mate cleanly before tightening retention screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Load:\u003c\/strong\u003e After hardware replacement, perform a \"Load with Contents\" operation from Control Builder to update operational parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Voltage Directive (LVD):\u003c\/strong\u003e EN 61010-1:2010\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive:\u003c\/strong\u003e EN 61326-1:2006, IEC 61326-1:2005\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668000207211,"sku":"8C-TPOXA1 51307153-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-tpoxa1-51307153-175-profibus-gateway-module-kevuqr2u2as_08b6b731-76d7-4c30-90e9-28bb1fb2fa1c.jpg?v=1765504993","url":"https:\/\/www.plcprotech.com\/products\/honeywell-8c-tpoxa1-51307153-175-experion-series-8-profibus-gateway-iota-coated","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}