{"product_id":"honeywell-8u-pwsp01-cn-experion-lx-series-8-20a-power-supply-module","title":"Honeywell 8U-PWSP01-CN Experion LX Series 8 20A Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8U-PWSP01-CN\u003c\/strong\u003e is a 20A power supply module designed for providing regulated DC system power in Experion LX Series 8 control environments. Operating on an AC input voltage rating of 120\/240 VAC, it converts line utility power into the stabilized +24 VDC output required by C300 controllers, Series 8 Input\/Output modules, and associated I\/O Termination Assemblies (IOTAs).\u003c\/p\u003e\n\u003cp\u003eAs a core element of the Experion LX Series 8 power subsystem, the \u003cstrong\u003e8U-PWSP01-CN\u003c\/strong\u003e mounts within the dedicated Series 8 metal power rack assembly. It transfers system voltage through top-mounted header boards to the cabinet power distribution network. In dual-access cabinet configurations, power systems can be deployed across both cabinet sides to maintain continuous operational coverage across all installed control hardware.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDelivers +24 VDC output with up to 20A current capacity to feed Series 8 I\/O modules and C300 control hardware.\u003c\/li\u003e\n\u003cli\u003eOperates on 120\/240 VAC line input voltage via terminal block connections for flexible power distribution.\u003c\/li\u003e\n\u003cli\u003eInstalls directly into the Series 8 power supply metal chassis, connecting to top header boards for cabinet-wide power distribution.\u003c\/li\u003e\n\u003cli\u003eSupports redundant dual-power module configurations when paired with a second 20A unit in the power rack.\u003c\/li\u003e\n\u003cli\u003eFeeds power directly into the cabinet distribution subsystem without requiring individual external DC power wiring runs to IOTAs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExperion LX Series 8 cabinet power distribution subsystems requiring primary or redundant 24 VDC power rails.\u003c\/li\u003e\n\u003cli\u003eCentralized +24 VDC power distribution for Honeywell C300 controllers, Control Firewalls, and Series 8 I\/O modules.\u003c\/li\u003e\n\u003cli\u003eContinuous processing, batch automation, and industrial control cabinets operating within Experion LX hardware architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8U-PWSP01-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eExperion LX Series 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e120 \/ 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e+24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Rating\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rack Interface\u003c\/td\u003e\n\u003ctd\u003eMetal Power System Rack (Part Number 51154886)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistribution Interface\u003c\/td\u003e\n\u003ctd\u003eHeader Board (Part Number 51307186)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that incoming AC line voltage matches the 120\/240 VAC rating before installing the 8U-PWSP01-CN module into the cabinet.\u003c\/li\u003e\n\u003cli\u003eEnsure line power feeder breakers are isolated and locked out prior to wiring the cabinet AC terminal block.\u003c\/li\u003e\n\u003cli\u003eMount the power supply module securely into the designated metal power supply rack inside the Series 8 cabinet.\u003c\/li\u003e\n\u003cli\u003eConnect user-supplied AC power conductors (L1, L2, and Safety Ground) through the cabinet entry port to the AC terminal block.\u003c\/li\u003e\n\u003cli\u003eVerify protective earth ground connections to ensure system safety and high electrical noise immunity.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration and Commissioning Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConduct continuity checks across the +24 VDC power distribution header board to verify there are no field short circuits.\u003c\/li\u003e\n\u003cli\u003eApply AC line power via the cabinet Circuit Breaker Box and measure the output at the header board to verify stable +24 VDC supply.\u003c\/li\u003e\n\u003cli\u003eInspect status LEDs on the power supply module to confirm proper initialization and power subsystem health.\u003c\/li\u003e\n\u003cli\u003eVerify proper cabinet ventilation and fan assembly operation to maintain acceptable operating ambient temperature limits.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668028748139,"sku":"8U-PWSP01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8u-pwsp01-cn-power-supply-module-ynl1mfeu1sw_5f039fb3-0f05-456f-a854-171a8b9b8f68.jpg?v=1765505302","url":"https:\/\/www.plcprotech.com\/products\/honeywell-8u-pwsp01-cn-experion-lx-series-8-20a-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}