{"product_id":"honeywell-900g02-0102-controledge-hc900-16-channel-24-vdc-digital-input-module","title":"Honeywell 900G02-0102 ControlEdge HC900 16 Channel 24 VDC Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 900G02-0102\u003c\/strong\u003e is a \u003cstrong\u003e16-channel 24 VDC digital input module\u003c\/strong\u003e designed for the \u003cstrong\u003eControlEdge HC900 controller system\u003c\/strong\u003e. It interfaces discrete field signals with the system rack, delivering signal processing and galvanic isolation between chassis ground and input channels.\u003c\/p\u003e\n\u003cp\u003eEach channel on the \u003cstrong\u003e900G02-0102\u003c\/strong\u003e digital input module monitors discrete state changes from field devices and reports channel status to the \u003cstrong\u003eControlEdge HC900\u003c\/strong\u003e CPU or scanner module. An onboard microprocessor conducts parallel signal processing per module to maintain high-speed execution across backplane racks. The device features front-panel LEDs for channel and module diagnostics and interfaces with detachable Euro or Barrier terminal blocks or Remote Termination Panels.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSenses 16 discrete 24 VDC digital input channels for process state monitoring\u003c\/li\u003e\n\u003cli\u003eDedicated onboard microprocessor in each module for parallel signal processing\u003c\/li\u003e\n\u003cli\u003eFront-panel status indicators for module status and individual channel activity\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between chassis ground and input channels\u003c\/li\u003e\n\u003cli\u003eCompatible with Euro style and Barrier style terminal blocks\u003c\/li\u003e\n\u003cli\u003eSupports Remote Termination Panel (RTP) wiring assemblies\u003c\/li\u003e\n\u003cli\u003eSupports Removal and Insertion Under Power (RIUP) during maintenance procedures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDiscrete device state monitoring in process control systems\u003c\/li\u003e\n\u003cli\u003eSequence and safety interlock state sensing in ControlEdge HC900 controller racks\u003c\/li\u003e\n\u003cli\u003eField signal integration for manufacturing unit operations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSIL Compatible\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e900G02-0102\u003c\/td\u003e\n\u003ctd\u003eDigital Input, 24 VDC (16 channel)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e900G02-0202\u003c\/td\u003e\n\u003ctd\u003eDigital Input, 24 VDC (16 channel) - SIL\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900G02-0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eControlEdge HC900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation (chassis to input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eDedicated microprocessor per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSIL Capability\u003c\/td\u003e\n\u003ctd\u003eNon-SIL (SIL Compatible: No)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eControlEdge HC900 Controller \/ Scanner Racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \/ Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block Options\u003c\/td\u003e\n\u003ctd\u003eEuro style (900TEK-0001) or Barrier style (900TBK-0001)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote Termination Panel\u003c\/td\u003e\n\u003ctd\u003eCompatible with RTP (900RTS-0001) via low voltage cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Jumpers\u003c\/td\u003e\n\u003ctd\u003eInternal jumpers for input circuit configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module securely into a designated slot in a ControlEdge HC900 controller rack or I\/O expansion rack.\u003c\/li\u003e\n\u003cli\u003eRoute field input wiring using appropriate wire gauges and terminate firmly at the detachable terminal block or RTP cable connector.\u003c\/li\u003e\n\u003cli\u003eMaintain shield grounding and wiring separation standards inside cabinet enclosures.\u003c\/li\u003e\n\u003cli\u003eAdhere to RIUP safety protocols before inserting or removing modules under power.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705766867307,"sku":"900G02-0102","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900G02-0102_003_1200x1200_36b7193f-04d6-4021-9f76-4009c03cfadc.jpg?v=1786366074","url":"https:\/\/www.plcprotech.com\/products\/honeywell-900g02-0102-controledge-hc900-16-channel-24-vdc-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}