{"product_id":"honeywell-900g32-0301-digital-input-24-vdc-module","title":"Honeywell 900G32-0301 Digital Input 24 VDC Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 900G32-0301\u003c\/strong\u003e is a high-density \u003cstrong\u003eDigital Input Module\u003c\/strong\u003e engineered for the ControlEdge HC900 system, providing 32 sinking input channels. This module is designed to monitor a wide range of 24 Vdc field signals, offering robust performance in harsh industrial environments with an extended operating temperature range. With integrated galvanic isolation split into two groups of 16, this module effectively separates field-side electrical activity from the internal backplane, enhancing system reliability and protecting critical control components from voltage transients.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Channel Density:\u003c\/strong\u003e 32 sinking input channels per module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Operating Range:\u003c\/strong\u003e Compatible with signal voltages from 10 Vdc to 32 Vdc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Two isolated groups of 16 inputs for enhanced noise immunity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Response:\u003c\/strong\u003e Consistent 5 ms response time for both ON-to-OFF and OFF-to-ON transitions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Thermal Specs:\u003c\/strong\u003e Certified for extended operation from -40 degC to 70 degC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRemote monitoring of digital sensors, limit switches, and contact closures\u003c\/li\u003e\n\u003cli\u003eHigh-density I\/O acquisition for DCS or PLC architectures\u003c\/li\u003e\n\u003cli\u003eSafety-related process interlock monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial machinery diagnostic feedback loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900G32-0301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input 24 Vdc Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs per Module\u003c\/td\u003e\n\u003ctd\u003e32 (sinking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e10 Vdc to 32 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e2 groups of 16 inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Voltage Level\u003c\/td\u003e\n\u003ctd\u003e9.5 Vdc (min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Voltage Level\u003c\/td\u003e\n\u003ctd\u003e3.5 Vdc (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e6.9 K ohms (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e5 ms (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp.\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp.\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.175 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Seating:\u003c\/strong\u003e Insert the module into the HC900 rack carefully to ensure the backplane pins are not bent; ensure the locking mechanism is fully engaged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSinking Configuration:\u003c\/strong\u003e Ensure field devices are wired for a sinking configuration, where the module provides the ground path for the input signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Management:\u003c\/strong\u003e Distribute field wiring to respect the two isolated groups of 16 inputs to maintain the electrical integrity provided by the module design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e The module supports extended operating temperatures; however, ensure adequate airflow within the cabinet to prevent localized hot spots that may exceed the 70 degC limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e For inputs routed through long cable runs, utilize shielded twisted-pair cabling and bond the shield to the common ground at the cabinet entry point.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705611055467,"sku":"900G32-0301","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900g32-0301-zqy1ar5islm_f1e36db5-9437-4722-b735-c3dd2df61170.jpg?v=1766651658","url":"https:\/\/www.plcprotech.com\/products\/honeywell-900g32-0301-digital-input-24-vdc-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}