{"product_id":"honeywell-900p01-0001-hc900-power-supply-module","title":"Honeywell 900P01-0001 HC900 Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding steady backplane power distribution, the \u003cstrong\u003eHoneywell 900P01-0001\u003c\/strong\u003e serves as the primary AC power supply module for the \u003cstrong\u003eHC900 Process \u0026amp; Safety Controller\u003c\/strong\u003e system. This module converts incoming line voltage to the regulated DC levels required by the rack backplane to support CPU, scanner, and input\/output modules. Engineered for high-availability industrial automation environments, it features robust transient protection, internal fusing, and a high-reliability hardware architecture that ensures uninterrupted operation under demanding thermal and electrical conditions.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eAuto-sensing universal AC input voltage range eliminates manual jumper configurations.\u003c\/li\u003e\n  \u003cli\u003eDelivers clean, regulated 5 VDC and 24 VDC rails directly to the HC900 backplane.\u003c\/li\u003e\n  \u003cli\u003eIntegral diagnostic monitoring relays status information directly to the controller CPU.\u003c\/li\u003e\n  \u003cli\u003eConvection-cooled design eliminates moving mechanical parts, increasing mean time between failures (MTBF).\u003c\/li\u003e\n  \u003cli\u003eSecure mechanical locking mechanism guarantees continuous electrical connection even in high-vibration applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eThermal processing control systems including industrial kilns, ovens, and environmental chambers.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater municipal treatment plant automation.\u003c\/li\u003e\n  \u003cli\u003eBoiler combustion control systems and burner management systems (BMS).\u003c\/li\u003e\n  \u003cli\u003eChemical and petrochemical batch processing installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eModel \/ Part Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e900P01-0001\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eSystem Compatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eHC900 Process \u0026amp; Safety Controller Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eInput Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 90 to 264 VAC (Universal input)\u0026lt;\/td\u0026gt;\n      \u0026lt;\/tr\u0026gt;\n      \u0026lt;tr style=\" border-bottom: solid\u003e\n        \u003c\/td\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eLine Frequency\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e47 to 63 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eMaximum Power Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e140 VA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOutput Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e60 Watts total backplane power\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eInrush Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e40 A maximum for 120 VAC, 80 A maximum for 240 VAC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eMounting Location\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDedicated leftmost slot of the HC900 rack\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eRelative Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3.0 kg (6.6 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e140 mm x 70 mm x 140 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eTerminal Connection\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eL (Line)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eAC Live Input (90 to 264 VAC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eN (Neutral)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eAC Neutral Input\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eGND \/ PE\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eProtective Earth Ground (Required for internal EMI filtering)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe \u003cstrong\u003e900P01-0001\u003c\/strong\u003e is intended for non-redundant power configurations on HC900 racks. If your application mandates a redundant power configuration to eliminate single points of failure, you must utilize the \u003cstrong\u003e900P02-0001\u003c\/strong\u003e Redundant Power Supply module along with the appropriate redundant backplane and power status module. These models are not interchangeable in terms of backplane slot spacing.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eA common issue in sealed field enclosures is thermal stagnation. While the \u003cstrong\u003e900P01-0001\u003c\/strong\u003e operates reliably up to 60 degC, prolonged exposure to high ambient temperatures accelerates the degradation of internal electrolytic capacitors. This degradation can lead to voltage ripple on the 5 VDC backplane rail, resulting in unexplained controller resets. Always maintain at least 50 mm of vertical clearance above and below the module rack to allow natural convective airflow.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFor critical control tasks, feed the AC input of the power supply from an isolation transformer or a dedicated UPS system. Sharing an AC line with large inductive loads like induction motors or magnetic contactors can induce high-energy spikes. Additionally, ensure the Protective Earth (PE) ground wire is connected directly to a low-impedance copper busbar; poor grounding degrades the internal EMI filter's efficacy and can introduce high-frequency noise into sensitive analog I\/O modules on the same rack.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present on the input terminals of this module. Disconnect, lock out, and tag out the primary AC power distribution circuit before attempting to install, wire, or remove the power supply module. Wait at least two minutes for internal filter capacitors to discharge fully before touching terminal connections.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; justify-content: center; align-items: center; min-width: 28px; height: 28px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 12px; font-size: 0.9rem;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; line-height: 1.5;\"\u003eConfirm that the rack chassis is securely mounted and grounded to the enclosure backplate.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; justify-content: center; align-items: center; min-width: 28px; height: 28px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 12px; font-size: 0.9rem;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; line-height: 1.5;\"\u003eAlign the 900P01-0001 module with the dedicated leftmost power slot on the HC900 rack. Slide the unit inward until the backplane connectors seat completely.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; justify-content: center; align-items: center; min-width: 28px; height: 28px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 12px; font-size: 0.9rem;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; line-height: 1.5;\"\u003eTighten the upper and lower module retaining screws to prevent accidental disconnects and to secure the module ground path.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; justify-content: center; align-items: center; min-width: 28px; height: 28px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 12px; font-size: 0.9rem;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; line-height: 1.5;\"\u003eStrip 14 AWG to 18 AWG copper wire to the manufacturer recommended length and connect the PE (Ground), Neutral, and Line conductors to their respective screw terminals.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; justify-content: center; align-items: center; min-width: 28px; height: 28px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 12px; font-size: 0.9rem;\"\u003e5\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; line-height: 1.5;\"\u003eVerify all wire connections are tight, close the protective terminal cover, and re-energize the source AC circuit to test.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705342587243,"sku":"900P01-0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900P01-0001-hbhwhef4v2t_ac44764e-6377-473f-b2cd-47018db7eba6.jpg?v=1766641045","url":"https:\/\/www.plcprotech.com\/products\/honeywell-900p01-0001-hc900-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}