{"product_id":"honeywell-900p01-0301-120-240vac-power-supply","title":"Honeywell 900P01-0301 120\/240VAC Power Supply","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 900P01-0301\u003c\/strong\u003e is a high-reliability \u003cstrong\u003e120\/240VAC Power Supply\u003c\/strong\u003e designed to provide stable, regulated power to the ControlEdge HC900 controller system. This module is engineered to handle a wide range of input voltages, making it adaptable to diverse industrial power grids. With an output rating of 58 W and integrated test jacks for easy monitoring of 5 Vdc and 24 Vdc rails, this power supply ensures consistent performance for sensitive control logic and field instrumentation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Input:\u003c\/strong\u003e Wide operating range of 90 to 264 V AC (47–63 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Efficiency:\u003c\/strong\u003e Delivers a 58 W output capacity from a 130 VA input rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Monitoring:\u003c\/strong\u003e Integrated test jacks for real-time verification of 5 Vdc and 24 Vdc output levels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Transient Handling:\u003c\/strong\u003e Designed for a 40 A peak-to-peak inrush current to ensure stability during power-up\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHold-up Capability:\u003c\/strong\u003e Provides 20 ms of hold-up time at 115 V AC to maintain system integrity during brief power interruptions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary power distribution for ControlEdge HC900 rack systems\u003c\/li\u003e\n\u003cli\u003eIndustrial automation cabinet power supply\u003c\/li\u003e\n\u003cli\u003eProcess control loop power source for PLC and DCS architectures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900P01-0301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e120\/240VAC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e90 to 264 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rating\u003c\/td\u003e\n\u003ctd\u003e58 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e40 A peak-to-peak (120 ms @ 240 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-up Time\u003c\/td\u003e\n\u003ctd\u003e20 ms @ 115 V AC (max load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Terminal\u003c\/td\u003e\n\u003ctd\u003eScrew type (0.3 mm2 to 3.3 mm2 \/ #12-22 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e137mm H x 72.6mm W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use appropriately sized cabling (#12-22 AWG) for the screw-type terminals; ensure all connections are tight to prevent resistive heating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Mount the power supply vertically to allow for natural convection cooling, maintaining the specified operational temperature range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection:\u003c\/strong\u003e The unit contains an internal non-replaceable fuse; ensure the input circuit is protected by an external appropriately rated circuit breaker to prevent damage during upstream faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring:\u003c\/strong\u003e Use the front-panel test jacks to periodically verify that the 5 Vdc and 24 Vdc outputs are within tolerance during preventative maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705608991083,"sku":"900P01-0301","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900p01-0301-u325hnrtmk0_500d3051-1b17-4f5b-a857-b79e0d1fe39d.jpg?v=1766651585","url":"https:\/\/www.plcprotech.com\/products\/honeywell-900p01-0301-120-240vac-power-supply","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}