{"product_id":"honeywell-asy782-030-led-connector-cable-30-ft","title":"Honeywell ASY782-030 LED Connector Cable 30-FT","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered specifically to facilitate reliable signal distribution in rugged industrial environments, the \u003cstrong\u003eHoneywell ASY782-030\u003c\/strong\u003e functions as a heavy-duty connector cable assembly with an integrated diagnostic status indicator. This \u003cstrong\u003e30-foot (9-meter)\u003c\/strong\u003e cable enables direct physical and electrical connection between field sensors, actuators, or burner control system components and local control panels. The embedded \u003cstrong\u003eLED indicator\u003c\/strong\u003e provides immediate, high-visibility visual feedback on power availability and signal status at the coupling point, minimizing troubleshooting downtime. Built with an oil-resistant, robust jacket, this assembly resists mechanical wear and chemical exposure typical of industrial manufacturing settings.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStatus Indicator:\u003c\/strong\u003e Integrated inline LED provides real-time signal and power verification at the physical junction.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGenerous Cable Run:\u003c\/strong\u003e 30-foot (9-meter) overall length supports long-distance routing across cable trays and conduit runs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Durability:\u003c\/strong\u003e Resilient outer jacket provides excellent protection against moisture, mechanical abrasion, and common industrial oils.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMolded Coupling:\u003c\/strong\u003e High-integrity molded connector body prevents ingress of particulate matter and fluids at the termination point.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStripped Lead Ends:\u003c\/strong\u003e Free end features pre-stripped conductors for fast terminal block termination inside control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 20px;\"\u003e\n  \u003cli\u003eBurner control systems and flame safeguard monitoring integration.\u003c\/li\u003e\n  \u003cli\u003eRemote industrial sensor-to-junction-box signaling loops.\u003c\/li\u003e\n  \u003cli\u003eProcess control setups requiring localized visual verification of active power paths.\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty machinery wiring in automotive, petrochemical, and packaging plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eValue \/ Rating\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eASY782-030\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCable Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e30 Feet (9 Meters)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDiagnostic Indicator\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIntegrated LED Status Light\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eConnector Style\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMolded Industrial Connector to Stripped Flying Leads\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eJacket Characteristics\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOil-resistant, high-flexibility synthetic polymer\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUnited States (or as specified by OEM)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.2 kg (Estimated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe ASY782-030 shares pin layouts and operational design parameters with the shorter 15-foot variations (such as the ASY782-015). For systems requiring shorter physical loop distances without cable slack management, the shorter versions can be swapped directly. Ensure your electrical drawings are updated if changing run lengths, as loop resistance differs slightly over long distances.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen deploying the 30-foot run, ensure the cable is not routed in immediate parallel proximity to high-voltage AC motor drives or heavy switching contactors to prevent electromagnetic interference from distorting low-level control signals. Although the cable outer jacket is highly durable, avoid placing sharp 90-degree bends immediately behind the molded LED connector body to prevent premature strain-relief failure under high vibration.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003eThe integrated diagnostic LED relies on correct electrical polarity. If the connected device is operational but the LED does not illuminate, verify that the signal positive and return lines are not transposed. Always terminate the shield drain wire (if equipped) strictly at the panel ground bus and never at both ends, thereby preventing ground loop interference across the 9-meter distance.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize all associated controllers, primary power supplies, and output relays before initiating installation or maintenance on this cable assembly. Verify that no voltage is present on the terminal block using a calibrated digital multimeter. Failure to isolate power can result in equipment damage, false triggering of safety loops, or electrical shock.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 15px; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 10px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; font-size: 14px;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003eInspect the molded connector end of the cable for dust, debris, or bent pins before physical engagement. Ensure the receiver socket on the device is completely clean and dry.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 10px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; font-size: 14px;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003eAlign the physical keyway on the molded connector to the socket. Push the plug firmly home and secure the retention mechanism (coupling nut or latch) to preserve IP environmental protection ratings.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 10px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; font-size: 14px;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003eRoute the 30-foot cable run through protective conduit or on designated trays. Maintain a minimum bend radius of ten times the overall cable diameter to prevent internal wire damage.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 10px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; font-size: 14px;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003eStrip the outer jacket at the control panel end to reveal the conductor insulation. Terminate according to the terminal assignments outlined in your system electrical drawings, and torque terminal block screws to the specified tension.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 10px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; font-size: 14px;\"\u003e5\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003eApply system power. Trigger the field device and verify that the inline status LED lights up to confirm signal flow and power path verification.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705334329707,"sku":"ASY782-030","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/asy782-030-qxysi3smm3g_214f3fcb-b42b-4e48-b29a-656fc226a4ed.jpg?v=1766640800","url":"https:\/\/www.plcprotech.com\/products\/honeywell-asy782-030-led-connector-cable-30-ft","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}