{"product_id":"honeywell-c200-tk-odk161-ac-output-module","title":"Honeywell C200 TK-ODK161 AC Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTK-ODK161\u003c\/strong\u003e is a high-density, isolated \u003cstrong\u003eAC Output Module\u003c\/strong\u003e designed for integration into Honeywell process automation systems. This module features 16 individually isolated output channels engineered to switch alternating current loads across a wide voltage spectrum ranging from 74 to 265 VAC at line frequencies of 47 to 63 Hz. Each output is constructed with dedicated galvanic isolation barriers to prevent cross-channel interference and shield supervisory backplane electronics from field-side electrical transients. Designed for reliable signal delivery to final control elements such as solenoids, motor starters, and indicators, the module incorporates zero-crossing synchronization to suppress electromagnetic interference and thermal stress during load transitions.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 individually isolated output circuits providing channel-to-channel and user-to-system galvanic separation.\u003c\/li\u003e\n\u003cli\u003eLow on-state voltage drop and optimized power dissipation parameters for dense cabinet enclosures.\u003c\/li\u003e\n\u003cli\u003eHigh peak surge current capability to accommodate inductive and capacitive inrush loads.\u003c\/li\u003e\n\u003cli\u003eIntegrated zero-crossing inhibition mechanisms to prolong field device operational life.\u003c\/li\u003e\n\u003cli\u003eDirect compatibility with high-density 36-position connection terminal blocks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eControl of industrial solenoid valves and actuators.\u003c\/li\u003e\n\u003cli\u003eInterfacing with fixed-speed AC motor starters and contactors.\u003c\/li\u003e\n\u003cli\u003eExecution of pilot light arrays and visual signaling systems.\u003c\/li\u003e\n\u003cli\u003eSegregated load switching in chemical, petrochemical, and power generation environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK-ODK161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAC Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e16 (individually isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e74-265 VAC, 47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Rating (Per Point)\u003c\/td\u003e\n\u003ctd\u003e2.0 A max @ 30 Celsius \u0026amp; 2.0 A max @ 60 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Rating (Per Module)\u003c\/td\u003e\n\u003ctd\u003e5.0 A max @ 30 Celsius \u0026amp; 4.0 A max @ 60 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Current\u003c\/td\u003e\n\u003ctd\u003e20 A for 43 ms each, repeatable every 2 sec @ 60 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Current (Minimum)\u003c\/td\u003e\n\u003ctd\u003e10 mA per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage Drop (Maximum)\u003c\/td\u003e\n\u003ctd\u003e1.5 Vrms @ 2.0 A, 6.0 Vrms @ I \u0026lt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inhibit Voltage\u003c\/td\u003e\n\u003ctd\u003e60 V peak (zero crossing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage Current (Maximum)\u003c\/td\u003e\n\u003ctd\u003e3 mA per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Delay (Off to On \/ On to Off)\u003c\/td\u003e\n\u003ctd\u003e9.3 ms @ 60 Hz; 11 ms @ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e9.6 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw (24 VDC)\u003c\/td\u003e\n\u003ctd\u003e0.002 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw (5 VDC)\u003c\/td\u003e\n\u003ctd\u003e0.300 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage (Channel to Channel)\u003c\/td\u003e\n\u003ctd\u003e100% tested at 2546 VDC for 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage (User to System)\u003c\/td\u003e\n\u003ctd\u003e100% tested at 2546 VDC for 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Terminal Blocks\u003c\/td\u003e\n\u003ctd\u003eTC-TBCH (36-position terminal block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC-TBCH Terminal Slot\u003c\/td\u003e\n\u003ctd\u003e36-position terminal block interface mapping for 16 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eGrounding and Shielding\u003c\/h3\u003e\n\u003cp\u003eEnsure that the chassis rack and mounting backplane are securely bonded to the plant instrumentation grounding network. Field wiring shields, if deployed for noise mitigation, must be terminated at designated shield grounding bars outside the module assembly to prevent stray currents from entering the control logic plane.\u003c\/p\u003e\n\u003ch3\u003eHandling and ESD Protection\u003c\/h3\u003e\n\u003cp\u003eElectrostatic discharge can degrade or destroy internal solid-state components. Prior to inserting, removing, or wiring the module, personnel must wear a properly grounded static-dissipative wrist strap. Store and transport the unit exclusively in approved anti-static protective packaging.\u003c\/p\u003e\n\u003ch3\u003eThermal Management and Airflow\u003c\/h3\u003e\n\u003cp\u003eReview thermal derating parameters when planning module layouts. Note that the total module current limits scale from 5.0 A at 30 Celsius down to 4.0 A at 60 Celsius. Maintain proper clearance margins between high-power equipment and the chassis to promote unhindered natural convection or forced-air circulation.\u003c\/p\u003e\n\u003ch3\u003eWiring and Terminal Block Assignment\u003c\/h3\u003e\n\u003cp\u003eAll field connections must be wired through the compatible TC-TBCH 36-position terminal block. Verify that the load requirements meet the minimum on-state threshold of 10 mA per output to guarantee proper switching operations and prevent leakage current false-activation states.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the electrical isolation rating between channels for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvery channel is fully isolated from adjacent circuits, withstanding testing procedures at 2546 VDC for a duration of 1 second.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the ambient operational temperature increases from 30 to 60 Celsius?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile individual points remain rated up to 2.0 A, the collective maximum module current capacity decreases from 5.0 A to 4.0 A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit switch low-power instrumentation signals below 10 mA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, a minimum on-state current threshold of 10 mA per output channel is necessary for the solid-state switching circuitry to operate correctly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific terminal block is required to interface with field wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis module requires the TC-TBCH 36-position terminal block for managing field-side connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this device feature zero-crossing switching attributes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it limits switching based on a maximum zero-crossing inhibit voltage threshold of 60 V peak to minimize inductive surges.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the typical output signal delay when operating on a standard 50 Hz line?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe propagation and signal processing delay for both turning on and turning off is approximately 11 ms at 50 Hz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much power does the module draw from the 24 VDC backplane supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe nominal continuous current consumption from the 24 VDC rail is extremely low, specified at 0.002 A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum transient surge current individual channels can tolerate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach output point can endure an inrush surge current of up to 20 A lasting for 43 ms, repeatable every 2 seconds at 60 Celsius.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat level of leakage current should be expected when an output is turned off?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe off-state leakage current can reach a maximum value of 3 mA per individual output point.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the net weight of the module excluding shipping materials?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unboxed module weight is exactly 1 kg.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705571635563,"sku":"TK-ODK161","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tk-odk161-qjsl1ws1ow0_0d805f04-5929-479d-aaf2-159b3d9bc8b7.jpg?v=1766650184","url":"https:\/\/www.plcprotech.com\/products\/honeywell-c200-tk-odk161-ac-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}