{"product_id":"honeywell-cc-gaix11-analog-input-gi-is-redundant-iota","title":"Honeywell CC-GAIX11 Analog Input GI\/IS Redundant IOTA","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-GAIX11\u003c\/strong\u003e is a Redundant Analog Input GI\/IS IOTA (Galvanic Isolation \/ Intrinsically Safe Input Output Termination Assembly) designed for high-availability process control within the Honeywell Experion PKS Series C I\/O architecture. It provides the physical and electrical interface required to land field sensor signals and route them securely to paired Series C Analog Input Modules, such as the \u003cstrong\u003e\u003ca href=\"\/products\/honeywell-cc-paih01-experion-series-c-analog-input-module-with-hart\"\u003eCC-PAIH01\u003c\/a\u003e\u003c\/strong\u003e, \u003cstrong\u003e\u003ca href=\"\/products\/honeywell-cc-paih02-series-c300-hart-analog-input-module\"\u003eCC-PAIH02\u003c\/a\u003e\u003c\/strong\u003e, \u003ca href=\"\/products\/honeywell-cc-paix01-51405038-275-experion-pks-series-c-high-level-analog-input-module\"\u003e\u003cstrong\u003eCC-PAIX01\u003c\/strong\u003e\u003c\/a\u003e, or \u003ca href=\"\/products\/honeywell-cc-paih02-51405038-375-c300-high-level-analog-input-with-hart\"\u003e\u003cstrong\u003eCC-PAIX02\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eBuilt for critical industrial operations, the \u003cstrong\u003eCC-GAIX11\u003c\/strong\u003e incorporates redundant IOM mounting positions directly on the board. This configuration allows two compatible Series C Analog Input Modules to operate in a parallel, redundant setup without requiring external switching hardware or additional cross-cabling. The assembly provides built-in signal conditioning and field power distribution, ensuring reliable data acquisition from 4-20mA and voltage transmitters across demanding processing environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Architecture:\u003c\/strong\u003e Supports two plug-in Series C I\/O modules on a single assembly for seamless hardware fault tolerance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation \/ Intrinsically Safe (GI\/IS) Support:\u003c\/strong\u003e Formed specifically to interface with galvanically isolated field circuits for safety-critical plant environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact 12-Inch Form Factor:\u003c\/strong\u003e Standardized 12-inch (304 mm) IOTA footprint maximizes cabinet density while providing full termination access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect-Bus Powering:\u003c\/strong\u003e Receives primary 24 VDC operating power directly from the mounting carrier bus, eliminating extra power distribution wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Signal Routing:\u003c\/strong\u003e Combines process signal conditioning and redundant network bus connection (I\/O LINK) on a single board assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetachable Screw Terminals:\u003c\/strong\u003e Features two-level field wiring terminals to facilitate simplified installation, maintenance, and field loops testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Field Interfacing:\u003c\/strong\u003e Integrates process transmitters installed in demanding process zones into the Experion C300 controller platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Analog Data Acquisition:\u003c\/strong\u003e Guarantees uninterrupted monitoring of critical process variables such as flow, pressure, level, and temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDCS Cabinet Optimization:\u003c\/strong\u003e Reduces overall enclosure footprint by integrating field terminations, power distribution, and redundancy on one board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-GAIX11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRedundant Analog Input GI\/IS IOTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eExperion Series C I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible IOM Models\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/honeywell-cc-paih01-experion-series-c-analog-input-module-with-hart\"\u003eCC-PAIH01\u003c\/a\u003e, \u003ca href=\"\/products\/honeywell-cc-paih02-series-c300-hart-analog-input-module\"\u003eCC-PAIH02\u003c\/a\u003e, \u003ca href=\"\/products\/honeywell-cc-paix01-51405038-275-experion-pks-series-c-high-level-analog-input-module\"\u003eCC-PAIX01\u003c\/a\u003e, \u003ca href=\"\/products\/honeywell-cc-paih02-51405038-375-c300-high-level-analog-input-with-hart\"\u003eCC-PAIX02\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eYes (Dual IOM Slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Size\u003c\/td\u003e\n\u003ctd\u003e12 inches (304 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Signal Types\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0 to 5 V, 1 to 5 V, 0.4 to 2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC via IOTA Carrier Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring Terminals\u003c\/td\u003e\n\u003ctd\u003eDetachable two-level terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Wire Size\u003c\/td\u003e\n\u003ctd\u003e12 AWG \/ 2.5 mm2 stranded wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOM Plug-in Slots\u003c\/td\u003e\n\u003ctd\u003eDual mounting positions for redundant High-Level Analog Input Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Terminal Blocks\u003c\/td\u003e\n\u003ctd\u003eDetachable 2-level screw terminals for field transmitter wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Power Interface\u003c\/td\u003e\n\u003ctd\u003eDirect bus connections for 24 VDC system power entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem I\/O Link\u003c\/td\u003e\n\u003ctd\u003eOn-board routing to the Experion C300 controller network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Inspection:\u003c\/strong\u003e Verify that the \u003cstrong\u003eCC-GAIX11\u003c\/strong\u003e assembly is undamaged and that the mounting carrier slots are clean and free of debris.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the IOTA onto the Series C cabinet enclosure base or carrier rail, ensuring proper engagement with the 24 VDC power bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Connections:\u003c\/strong\u003e Land field wiring on the two-level detachable terminal blocks using stranded wire up to 12 AWG (2.5 mm²). Ensure shield and signal commons are properly routed according to plant grounding guidelines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Carefully align and plug the designated Analog Input Modules (e.g., CC-PAIH02 or CC-PAIX02) into the primary and redundant IOM positions on the IOTA until fully seated and locked.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Verification:\u003c\/strong\u003e Confirm proper 24 VDC supply voltage at the carrier bus prior to commissioning control loops.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52679467532651,"sku":"CC-GAIX11","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-gaix11-analog-input-module-dvknmzlqlzt.jpg?v=1765450155","url":"https:\/\/www.plcprotech.com\/products\/honeywell-cc-gaix11-analog-input-gi-is-redundant-iota","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}