{"product_id":"honeywell-cc-paih02-51405038-375-c300-high-level-analog-input-with-hart","title":"Honeywell CC-PAIH02 51405038-375 C300 High Level Analog Input with HART","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAIH02\u003c\/strong\u003e is a 16-channel High Level Analog Input module with HART capability designed for the Experion PKS Series C I\/O family. Engineered to operate under the control of a \u003cstrong\u003eHoneywell C300\u003c\/strong\u003e controller via the high-speed I\/O Link network, the module performs signal conditioning, A\/D conversion, and input scanning independently of controller processing execution.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eCC-PAIH02\u003c\/strong\u003e features differential input support across all 16 channels, providing robust noise immunity and accurate signal conditioning for standard 4–20 mA process loops. Equipped with onboard HART modems, the module enables multi-variable digital communication with smart field transmitters without requiring additional marshalling hardware. Dedicated open-wire detection diagnostics safeguard critical process loops by identifying broken field wiring promptly to prevent false process variable (PV) readings.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Differential Input Channels:\u003c\/strong\u003e Supports differential 4–20 mA analog input signals across all 16 channels for superior noise rejection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated HART Communication:\u003c\/strong\u003e Features built-in HART modems to support HART-capable, multi-variable field transmitters and pass-through secondary variables to the control system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Loop Scan Rate:\u003c\/strong\u003e Delivers a 50 ms loop scan rate to ensure rapid updating of process variables for continuous control strategies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroken-Wire Detection:\u003c\/strong\u003e Onboard diagnostic monitoring detects open field circuits on 4–20 mA loops and alerts operators via soft failure alarms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Incendive Field Power:\u003c\/strong\u003e Delivers non-incendive power directly to field transmitters without requiring external marshalling or safety barriers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIOM Redundancy Support:\u003c\/strong\u003e Configurable for optional hardware redundancy on the standard IOTA board to maintain process availability during module maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Process Monitoring:\u003c\/strong\u003e Interfacing standard 2-wire and self-powered 4–20 mA flow, pressure, level, and temperature transmitters with the C300 controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Field Device Integration:\u003c\/strong\u003e Extracting secondary HART diagnostic variables and multivariable readings directly into Experion PKS control strategies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential Voltage \/ Current Measurement:\u003c\/strong\u003e Applications requiring differential analog signal connections to eliminate ground loop interference across field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eCC-PAIH02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51405038-375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series C I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHigh Level Analog Input Module with HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eInput \/ Output\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e4–20 mA \/ 0–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eDifferential (Supported on all 16 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Rate\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eIntegrated HART (HART 6.0 and later compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eOpen-wire detection \/ soft failure reporting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd\u003e18-degree tilt angle on Series C IOTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-Pin IOTA Connector\u003c\/td\u003e\n\u003ctd\u003eMates directly to Series C Input Output Termination Assembly (IOTA) for power, field signals, and backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Link Network\u003c\/td\u003e\n\u003ctd\u003eRedundant serial I\/O link interface connecting the module to the C300 controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Inspection:\u003c\/strong\u003e Verify the part number \u003cstrong\u003e51405038-375\u003c\/strong\u003e on the module label and inspect the edge connector pins for physical damage before mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIOTA Carrier Mounting:\u003c\/strong\u003e Ensure the corresponding Series C IOTA (such as CC-TAIX02 or CC-TAIX51\/61 series) is securely fastened to the carrier frame and properly grounded.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Align the tilted module guide rails with the IOTA connector slot and press firmly until the locking mechanism fully engages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Check:\u003c\/strong\u003e Verify that field loops (2-wire or self-powered 3\/4-wire transmitters) are wired in according to the differential signal polarity indicated in the IOTA pinout diagram.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Link Connection:\u003c\/strong\u003e Ensure the redundant I\/O Link cables are securely connected to the carrier assembly and assigned a unique address jumper on the IOTA prior to powering on.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \/ Commissioning \/ Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Builder Configuration:\u003c\/strong\u003e Add the AI-HART module block under the appropriate IOLINK block in Control Builder and assign the module address matching the physical IOTA jumpers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Parameterization:\u003c\/strong\u003e Set each channel's PV range, engineering units, characterization type (linear, square root), and HART configuration settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParameter Backup \u0026amp; Switchover:\u003c\/strong\u003e When replacing an existing module, verify that the active C300 controller has backed up the module configuration. Inserting the new module into the active IOTA slot will automatically download the existing parameter set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning Validation:\u003c\/strong\u003e Use the Control Builder Monitoring tab to verify PV readings, check loop current values, and confirm HART communication status for connected field instruments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705318109547,"sku":"CC-PAIH02 51405038-375","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-paih02-51405038-375-analog-input-module-rzag0capiej.jpg?v=1765450173","url":"https:\/\/www.plcprotech.com\/products\/honeywell-cc-paih02-51405038-375-c300-high-level-analog-input-with-hart","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}