{"product_id":"honeywell-cc-paix01-51405038-275-experion-pks-series-c-high-level-analog-input-module","title":"Honeywell CC-PAIX01 51405038-275 Experion PKS Series C High-Level Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAIX01\u003c\/strong\u003e (Part Number \u003cstrong\u003e51405038-275\u003c\/strong\u003e) is a 16-channel High-Level Analog Input (HLAI) module designed for the Honeywell Experion PKS Series C I\/O family. Engineered to interface directly with a Honeywell C300 controller via the dedicated I\/O Link network, the module provides high-density signal conditioning and A\/D conversion for standard industrial analog current and voltage field transmitters.\u003c\/p\u003e\n\u003cp\u003eOperating under the control of the C300 controller using the AI-HL IOM function block in Control Builder, the \u003cstrong\u003eCC-PAIX01\u003c\/strong\u003e processes incoming field signals independently of the main controller execution cycle. The module supports differential input configurations on channels 13 through 16 alongside single-ended high-level inputs, offering signal flexibility and noise suppression for critical process loops.\u003c\/p\u003e\n\u003cp\u003eDesigned for demanding process control environments, the \u003cstrong\u003e51405038-275\u003c\/strong\u003e module mounts directly onto Series C Input Output Termination Assemblies (IOTAs). It supports hardware redundancy when installed on compatible redundant IOTA boards, enabling automatic switchover and continuous process monitoring without interruption. Note that the \u003cstrong\u003eCC-PAIX01\u003c\/strong\u003e model has been officially succeeded by the \u003ca href=\"\/products\/honeywell-cc-paih02-51405038-375-c300-high-level-analog-input-with-hart\"\u003e\u003cstrong\u003eCC-PAIX02\u003c\/strong\u003e\u003c\/a\u003e model, which expands differential input support across all 16 channels.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 High-Level Channels:\u003c\/strong\u003e Provides 16 input channels designed to accept high-level analog signals from 2-wire and self-powered field transmitters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelectable Differential Inputs:\u003c\/strong\u003e Supports differential input signal connections on channels 13 through 16 for enhanced common-mode noise rejection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC300 \u0026amp; I\/O Link Integration:\u003c\/strong\u003e Communicates natively with C300 controllers over the I\/O Link network via the AI-HL function block in Control Builder.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e Fully supports redundant hardware configurations on designated Series C IOTAs to maintain process availability during single-module maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable Design:\u003c\/strong\u003e Mounts onto Series C IOTAs with an angled insertion design, enabling online removal and replacement under power without disturbing field wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnboard Diagnostics:\u003c\/strong\u003e Integrates self-diagnostic capabilities with CTools software monitoring to report hardware health and firmware status in real time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Process Monitoring:\u003c\/strong\u003e Interfacing standard high-level current and voltage field transmitters with Experion PKS control systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential Signal Acquisition:\u003c\/strong\u003e Connecting noisy or non-isolated analog loops on channels 13 through 16 to eliminate ground loop interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Loop Feedback:\u003c\/strong\u003e Supplying high-density analog process variables (PV) for flow, pressure, temperature, and level loops managed by C300 controllers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Model\u003c\/td\u003e\n\u003ctd\u003eCC-PAIX01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51405038-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series C I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Analog Input Module (Non-HART)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell C300 Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOM Block Name\u003c\/td\u003e\n\u003ctd\u003eAI-HL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuccessor Model\u003c\/td\u003e\n\u003ctd\u003eCC-PAIX02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eInput \/ Output\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Current \/ Voltage (Non-HART)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDifferential Input Channels\u003c\/td\u003e\n\u003ctd\u003eChannels 13 through 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eSeries C I\/O Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Method\u003c\/td\u003e\n\u003ctd\u003eHoneywell Control Builder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eOperational Capabilities\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSupported on redundant IOTA boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInitialization Time (Module Power Loss)\u003c\/td\u003e\n\u003ctd\u003e10 seconds (+\/- 25%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Switchover Performance\u003c\/td\u003e\n\u003ctd\u003eEquivalent to PM I\/O switchover time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear Board Edge Connector\u003c\/td\u003e\n\u003ctd\u003eConnects directly to Series C Input Output Termination Assembly (IOTA) for power, backplane bus, and field signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries C I\/O Link\u003c\/td\u003e\n\u003ctd\u003eSerial communication link managed by the C300 controller for data transfer and module programming\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Inspection:\u003c\/strong\u003e Confirm the exact part number \u003cstrong\u003e51405038-275\u003c\/strong\u003e on the module side label and inspect the physical connector pins for damage prior to installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIOTA Mounting:\u003c\/strong\u003e Ensure the target Series C IOTA carrier is securely fastened inside the cabinet and properly bonded to protective earth ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Align the module housing with the guide tracks of the target IOTA slot. Slide the module in at the standard 18-degree tilt angle until the locking latches click firmly into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Verification:\u003c\/strong\u003e Route high-level analog current or voltage input signal wires to the corresponding terminals on the IOTA. Ensure differential signal sources are correctly assigned to channels 13 through 16.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Link Verification:\u003c\/strong\u003e Verify that the I\/O Link cable connectors on the IOTA carrier are tight and assigned the correct physical address jumper matching the software setup.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \/ Commissioning \/ Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Builder Setup:\u003c\/strong\u003e Assign an AI-HL module block under the corresponding IOLINK master block in Honeywell Control Builder, matching the assigned hardware address on the IOTA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Module Replacement:\u003c\/strong\u003e When replacing an older revision \u003cstrong\u003eCC-PAIX01\u003c\/strong\u003e module in a redundant pair, verify hardware revision levels. For systems running Experion PKS R310 or later, ensure the controller patch level is updated before pairing older (rev \u0026lt;=K) and newer (rev \u0026gt;=M) hardware revisions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnline Switchover Check:\u003c\/strong\u003e Upon inserting a replacement module into an energized IOTA slot, monitor CTools to verify that firmware synchronization completes and the module status transitions to green\/active.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667736981867,"sku":"CC-PAIX01 51405038-275","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-paix01-51405038-275-analog-input-module-hknbcxbtnph_4f3b11b1-8363-4f10-bee1-164b1ceb123a.jpg?v=1765501331","url":"https:\/\/www.plcprotech.com\/products\/honeywell-cc-paix01-51405038-275-experion-pks-series-c-high-level-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}