{"product_id":"honeywell-cc-paon01-51410070-175-experion-pks-series-c-non-hart-analog-output-module","title":"Honeywell CC-PAON01 51410070-175 Experion PKS Series C Non-HART Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAON01\u003c\/strong\u003e (Part Number \u003cstrong\u003e51410070-175\u003c\/strong\u003e) is a 16-channel non-HART analog output module engineered for process automation applications within the Honeywell Experion Process Knowledge System (PKS) Series C architecture. Operating on the Series C I\/O link (IOLINK) mastered by a C300 controller, the module delivers 4-20 mA control signals to field elements such as control valves, actuators, positioners, and variable speed drives.\u003c\/p\u003e\n\u003cp\u003eDesigned as an updated functional successor to earlier CC-PAOX01 and CU-PAOX01 hardware models, the \u003cstrong\u003eCC-PAON01\u003c\/strong\u003e utilizes the standard AO16 function block in Experion Control Builder. The module mounts directly onto dedicated Series C Input Output Termination Assemblies (IOTA), integrating into single or redundant IOLINK topographies.\u003c\/p\u003e\n\u003cp\u003eIn Experion PKS control architectures, the \u003cstrong\u003eCC-PAON01\u003c\/strong\u003e supports both non-redundant and 1-on-1 redundant hardware configurations. Following localized power disruptions, single I\/O modules complete initialization in 10 seconds (+\/- 25%), resuming control loop processing without requiring full system reboots.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 16 analog output channels dedicated to non-HART 4-20 mA field control loops.\u003c\/li\u003e\n\u003cli\u003eInterfaces directly with C300 controllers over the Series C I\/O link (IOLINK) network.\u003c\/li\u003e\n\u003cli\u003eConfigured and executed in Experion Control Builder using the standard AO16 IOM block structure.\u003c\/li\u003e\n\u003cli\u003eServes as the direct functional replacement model for legacy CC-PAOX01 and CU-PAOX01 modules.\u003c\/li\u003e\n\u003cli\u003eSupports non-redundant (CC-TAON01) and redundant (CC-TAON11) Field Termination Assemblies.\u003c\/li\u003e\n\u003cli\u003eRapid module-level initialization completes within 10 seconds (+\/- 25%) following power restoration.\u003c\/li\u003e\n\u003cli\u003eSupports up to 40 redundant IOMs per IOLINK and up to 80 redundant IOMs per C300 controller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModulating final control elements including 4-20 mA control valves, I\/P converters, and positioners.\u003c\/li\u003e\n\u003cli\u003eProviding analog control speed references to variable frequency drives (VFD) and motor controllers.\u003c\/li\u003e\n\u003cli\u003eIntegrating non-HART analog output field loops into Experion PKS C300 process automation systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eCC-PAON01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51410070-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSeries C Non-HART Analog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl System Compatibility\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series C \/ C300 Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA (Non-HART)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction Block Type\u003c\/td\u003e\n\u003ctd\u003eAO16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Non-Redundant IOTA\u003c\/td\u003e\n\u003ctd\u003eCC-TAON01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Redundant IOTA\u003c\/td\u003e\n\u003ctd\u003eCC-TAON11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Communication Interface\u003c\/td\u003e\n\u003ctd\u003eSeries C IOLINK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Modules per IOLINK\u003c\/td\u003e\n\u003ctd\u003e40 redundant IOMs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Modules per C300 Controller\u003c\/td\u003e\n\u003ctd\u003e80 redundant IOMs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle Module Initialization Time\u003c\/td\u003e\n\u003ctd\u003e10 seconds (+\/- 25%) after module power restoration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet-Level Initialization Time\u003c\/td\u003e\n\u003ctd\u003e60 seconds (+\/- 25%) after cabinet power restoration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperseded Models\u003c\/td\u003e\n\u003ctd\u003eCC-PAOX01, CU-PAOX01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAssembly Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Redundant IOTA\u003c\/td\u003e\n\u003ctd\u003eCC-TAON01\u003c\/td\u003e\n\u003ctd\u003eSingle-channel field termination assembly for CC-PAON01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant IOTA\u003c\/td\u003e\n\u003ctd\u003eCC-TAON11\u003c\/td\u003e\n\u003ctd\u003eDual-channel redundant field termination assembly for CC-PAON01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that the module model (CC-PAON01) and part number (51410070-175) match engineering design drawings before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm cabinet logic power status and observe ESD protection procedures before handling the module assembly.\u003c\/li\u003e\n\u003cli\u003eAlign the rear connector of the CC-PAON01 with the designated slot on the CC-TAON01 or CC-TAON11 IOTA base.\u003c\/li\u003e\n\u003cli\u003ePress the module onto the IOTA mounting position until the securing latches click into place.\u003c\/li\u003e\n\u003cli\u003eInspect field wiring connected to the IOTA screw terminals to ensure secure wire termination and shielding ground connections.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \/ Commissioning \/ Replacement Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlock Assignment\u003c\/strong\u003e: In Experion Control Builder, assign the channel configuration using the standard AO16 function block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLink Configuration\u003c\/strong\u003e: Ensure the C300 controller IOLINKTYPE parameter is set correctly to support Series C I\/O modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Restrictions\u003c\/strong\u003e: When replacing older CC-PAOX01 units with CC-PAON01, note that mixed redundant pairs (pairing a PAOX01 with a PAON01) are not supported; online migration requires identical hardware pairs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning Verification\u003c\/strong\u003e: Measure loop current across the output terminals using a calibrated meter prior to placing the corresponding control loop into automatic mode.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667744911723,"sku":"CC-PAON01 51410070-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-paon01-51410070-175-analog-output-module-15ttl14pgnq_6f9cb4a6-3951-407d-89e5-d605928abeb7.jpg?v=1765501464","url":"https:\/\/www.plcprotech.com\/products\/honeywell-cc-paon01-51410070-175-experion-pks-series-c-non-hart-analog-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}