{"product_id":"honeywell-cc-paon01-51410070-176-series-c-non-hart-analog-output-module","title":"Honeywell CC-PAON01 51410070-176 Series C Non-HART Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAON01 51410070-176\u003c\/strong\u003e is a 16-channel non-HART Analog Output Module (AOM) designed for execution within the Experion PKS Series C I\/O architecture. Operating on an IOLINK managed by a C300 controller, the module receives digital control commands from the controller software and generates precise, analog 4-20mA current signals to drive field actuators, control valves, positioners, and variable speed drives.\u003c\/p\u003e\n\u003cp\u003eEngineered as a core component of the Experion PKS automation platform, the \u003cstrong\u003eHoneywell CC-PAON01 51410070-176\u003c\/strong\u003e occupies a dedicated slot on a compatible Input Output Termination Assembly (IOTA). It utilizes an IOM block designation of AO. The module features a vertical, tilted form factor optimized for cabinet heat dissipation, toolless field replacement, and seamless integration with single or redundant IOTA configurations.\u003c\/p\u003e\n\u003cp\u003eCompared to earlier analog output variants such as the CC-PAOX01, the \u003cstrong\u003eHoneywell CC-PAON01 51410070-176\u003c\/strong\u003e represents an updated hardware baseline designed for non-HART loop control. In redundant implementations, paired modules share the control load and provide auto-failover, ensuring continuous output generation for critical process loops.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures 16 independent analog output channels designed for standard non-HART 4-20mA process control loops.\u003c\/li\u003e\n\u003cli\u003eUses the standardized AO IOM function block within Experion PKS Control Builder software.\u003c\/li\u003e\n\u003cli\u003eConnects directly to Experion C300 controllers over redundant IOLINK communications networks.\u003c\/li\u003e\n\u003cli\u003eCompatible with both non-redundant (CC-TAON01) and redundant (CC-TAON11) Series C I\/O Termination Assemblies.\u003c\/li\u003e\n\u003cli\u003eFast startup cycle capable of initializing in approximately 10 seconds following module-level power restoration.\u003c\/li\u003e\n\u003cli\u003eSupports high-density cabinet mounting with Series C vertical inclination for efficient thermal management.\u003c\/li\u003e\n\u003cli\u003eOn-board diagnostic reporting continuously updates module status and hardware health to the Experion system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinal Control Element Driving:\u003c\/strong\u003e Delivers 4-20mA analog current signals to control valves, I\/P converters, and electronic valve positioners.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed Reference Signals:\u003c\/strong\u003e Sends continuous setpoint control signals to Variable Frequency Drives (VFDs) and motor control centers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Process Control Loops:\u003c\/strong\u003e Serves as the primary analog output interface for pressure, flow, temperature, and level regulation across process industries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDCS Upgrades and Expansions:\u003c\/strong\u003e Serves as the updated Series C module model for expanding or replacing legacy non-HART analog output channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eCC-PAON01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51410070-176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSeries C Analog Output Module (Non-HART)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eExperion PKS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Interface\u003c\/td\u003e\n\u003ctd\u003eC300 Controller via IOLINK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Communication\u003c\/td\u003e\n\u003ctd\u003eNot Supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOM Block Name\u003c\/td\u003e\n\u003ctd\u003eAO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquivalent PM I\/O IOP Type\u003c\/td\u003e\n\u003ctd\u003eAO16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Non-Redundant IOTA\u003c\/td\u003e\n\u003ctd\u003eCC-TAON01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Redundant IOTA\u003c\/td\u003e\n\u003ctd\u003eCC-TAON11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Initialization Time\u003c\/td\u003e\n\u003ctd\u003e10 seconds (±25%) post module power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Level Recovery Time\u003c\/td\u003e\n\u003ctd\u003e60 seconds (±25%) post cabinet power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface \/ Assembly\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane\/IOTA Connector\u003c\/td\u003e\n\u003ctd\u003eConnects the module to the IOTA board for internal 24V DC power and dual IOLINK communications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-TAON01 Terminal Block\u003c\/td\u003e\n\u003ctd\u003eInterface for 16 non-redundant field output loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-TAON11 Terminal Block\u003c\/td\u003e\n\u003ctd\u003eDual-module interface providing redundant 16-channel field output connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \u0026amp; Compatibility Check:\u003c\/strong\u003e Verify that the physical module part number (CC-PAON01 \/ 51410070-176) matches system design and that the destination IOTA is model CC-TAON01 (non-redundant) or CC-TAON11 (redundant).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower \u0026amp; Safety:\u003c\/strong\u003e Ensure cabinet power distribution conforms to Honeywell Series C installation requirements. Keep the ESD grounding strap attached while handling the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Align the module guide pins with the dedicated slot on the IOTA board. Press firmly until the module latches securely into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Verification:\u003c\/strong\u003e Confirm that field loop wiring is properly connected to the screw terminals or field wiring connectors on the IOTA board prior to energizing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Initialization:\u003c\/strong\u003e Apply system power. The module will complete its internal diagnostic self-test and initialize within approximately 10 seconds.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \u0026amp; Replacement Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Configuration:\u003c\/strong\u003e In Experion Control Builder, assign the module using the AO IOM function block. Ensure the corresponding IOLINK block is configured for Series C I\/O communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy Model Migration:\u003c\/strong\u003e Note that CC-PAON01 is the designated updated model for the older CC-PAOX01 analog output module. Because CC-PAON01 and CC-PAOX01 cannot be mixed within a redundant pair, both modules in a redundant configuration must be updated simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Module Replacement:\u003c\/strong\u003e When replacing one module of an active redundant pair, verify that the active module is healthy. Insert the replacement module into the secondary slot on the CC-TAON11 IOTA. The controller will sync firmware and parameters to the new module automatically.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667752677739,"sku":"CC-PAON01 51410070-176","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-paon01-51410070-176-analog-output-module-tzbo4c1tlzd_55ed9c8b-7d02-47fa-9f85-481a243645f1.jpg?v=1765501582","url":"https:\/\/www.plcprotech.com\/products\/honeywell-cc-paon01-51410070-176-series-c-non-hart-analog-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}