{"product_id":"honeywell-cc-pcnt01-51405046-175-experion-series-c-c300-controller-module","title":"Honeywell CC-PCNT01 51405046-175 Experion Series C C300 Controller Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PCNT01(Part Number: \u003cspan\u003e51405046-175\u003c\/span\u003e)\u003c\/strong\u003e is a C300 controller module designed for distributed process control and I\/O gateway operation within the Honeywell Experion PKS Series C automation architecture.\u003c\/p\u003e\n\u003cp\u003eThe module features conformally coated printed circuit assemblies enclosed in a protective plastic housing with integrated LED status indicators and a local display. Operating on a chassis-less design, the \u003cstrong\u003eHoneywell CC-PCNT01\u003c\/strong\u003e plugs directly onto an Input Output Termination Assembly (IOTA), specifically the \u003cstrong\u003eCC-TCNT01\u003c\/strong\u003e, eliminating the need for a separate physical rack or backplane.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PCNT01\u003c\/strong\u003e supports both non-redundant and fully redundant control topologies. High-availability redundancy is integrated directly into the controller design, enabling seamless dual-controller pairing via a dedicated redundancy link cable. The unit interfaces with field I\/O through dual I\/O Link channels and integrates into plant supervisory systems via Fault Tolerant Ethernet (FTE) connections provided on the underlying termination assembly.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExecutes distributed process control functions and acts as an I\/O gateway for Experion Series C systems.\u003c\/li\u003e\n\u003cli\u003eUtilizes a chassis-less Series C form factor that mounts directly to a dedicated Input Output Termination Assembly.\u003c\/li\u003e\n\u003cli\u003eFeatures conformally coated circuit boards (CC prefix) for added environmental protection against industrial contaminants.\u003c\/li\u003e\n\u003cli\u003eSupports non-redundant and fully redundant high-availability operating modes with automatic synchronization.\u003c\/li\u003e\n\u003cli\u003eEquipped with front-panel LED status indicators and an alphanumeric display for direct operational monitoring.\u003c\/li\u003e\n\u003cli\u003eConnects to field I\/O networks via dual I\/O Link interface connections on the base termination assembly.\u003c\/li\u003e\n\u003cli\u003eReceives regulated 24VDC system power directly through the termination assembly interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed Process Control:\u003c\/strong\u003e Executing complex continuous, batch, and logic control algorithms in plant automation environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExperion Series C Network Gateway:\u003c\/strong\u003e Interfacing Series C I\/O modules with Experion PKS human-machine interfaces and supervisory networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Availability Operations:\u003c\/strong\u003e Providing continuous, uninterrupted control in critical processing applications requiring full hardware redundancy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eCC-PCNT01\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51405046-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eC300 Controller Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform \/ Series\u003c\/td\u003e\n\u003ctd\u003eExperion Series C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Coating\u003c\/td\u003e\n\u003ctd\u003eConformal Coated (CC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Function\u003c\/td\u003e\n\u003ctd\u003eDistributed Process Controller and I\/O Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Current Rating\u003c\/td\u003e\n\u003ctd\u003e0.311 A @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Form Factor\u003c\/td\u003e\n\u003ctd\u003eChassis-less mount onto IOTA (CC-TCNT01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Capability\u003c\/td\u003e\n\u003ctd\u003eNon-redundant and fully redundant support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Diagnostics\u003c\/td\u003e\n\u003ctd\u003eFront-panel status indicators and local display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Network Interfacing\u003c\/td\u003e\n\u003ctd\u003eDual I\/O Link channels via IOTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003ePlastic housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface (via IOTA CC-TCNT01)\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFTE Connections\u003c\/td\u003e\n\u003ctd\u003eDual Fault Tolerant Ethernet ports for supervisory network integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Link Terminations\u003c\/td\u003e\n\u003ctd\u003eDual I\/O Link cable ports for Series C I\/O communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Port\u003c\/td\u003e\n\u003ctd\u003eDedicated synchronization cable interface for redundant pair operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Terminal\u003c\/td\u003e\n\u003ctd\u003eRegulated 24 VDC main power distribution to controller logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Terminations\u003c\/td\u003e\n\u003ctd\u003eDedicated terminals for time synchronization source and battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that the system power distribution supply provides a stable 24 VDC and that the target slot uses a compatible CC-TCNT01 IOTA.\u003c\/li\u003e\n\u003cli\u003eInspect the rear electrical connectors and plastic housing of the CC-PCNT01 module for physical damage prior to installation.\u003c\/li\u003e\n\u003cli\u003eAlign the module housing with the mounting guides on the CC-TCNT01 termination assembly.\u003c\/li\u003e\n\u003cli\u003ePress the module firmly onto the IOTA connector until the retention latches engage fully.\u003c\/li\u003e\n\u003cli\u003eVerify that all network, I\/O Link, and redundancy cables connected to the underlying IOTA are properly secured.\u003c\/li\u003e\n\u003cli\u003eApply 24 VDC system power and monitor the front-panel status display to confirm proper module initialization.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConnect to the controller using Control Builder engineering software via the Fault Tolerant Ethernet (FTE) network.\u003c\/li\u003e\n\u003cli\u003eAssign the controller node address and network communication parameters in the Experion hardware configuration tree.\u003c\/li\u003e\n\u003cli\u003eFor redundant operations, configure the secondary controller node and confirm signal synchronization across the dedicated redundancy link.\u003c\/li\u003e\n\u003cli\u003eDownload the control strategy to the CC-PCNT01 module and perform a parameter backup.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify system strategy backups are up to date. If operating in a redundant pair, ensure the secondary controller is online and synchronized.\u003c\/li\u003e\n\u003cli\u003eIsolate power to the controller slot or initiate a controlled failover to the standby unit before removing the module.\u003c\/li\u003e\n\u003cli\u003eRelease the mechanical retention clips on the CC-PCNT01 and pull the module straight off the CC-TCNT01 IOTA.\u003c\/li\u003e\n\u003cli\u003eMount the replacement CC-PCNT01 module securely onto the IOTA connector and restore system power.\u003c\/li\u003e\n\u003cli\u003eVerify that the replacement unit establishes network connectivity, downloads configuration data, and returns to normal operational status.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52679400194411,"sku":"CC-PCNT01 51405046-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CC-PCNT01-51405046-175_005_1200x1200_9edff00e-f74e-4036-b8de-d7f9e1dc7b34.jpg?v=1786881536","url":"https:\/\/www.plcprotech.com\/products\/honeywell-cc-pcnt01-51405046-175-experion-series-c-c300-controller-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}