{"product_id":"honeywell-cc-pdih01-experion-series-c-digital-input-high-voltage-module","title":"Honeywell CC-PDIH01 Experion Series-C Digital Input High Voltage Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell \u003cstrong\u003eCC-PDIH01\u003c\/strong\u003e is a high-density digital input module designed for process control and monitoring applications within the Experion Series-C I\/O platform. It serves as a field interface for high-voltage discrete signals, accepting inputs from field contactors, switches, and interlocks to convey binary system states to the C300 controller.\u003c\/p\u003e\n\u003cp\u003eFeaturing 32 input channels, the \u003cstrong\u003eCC-PDIH01\u003c\/strong\u003e provides isolated sensing across various high-voltage AC and DC field levels depending on the selected Input Output Termination Assembly (IOTA). By utilizing a universal Input Output Module (IOM) hardware unit paired with specialized high-voltage IOTAs, the module streamlines system spare parts management while delivering galvanically isolated field signal processing for industrial plants.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Channel Density:\u003c\/strong\u003e Provides 32 discrete input sensing channels within a compact Series-C module footprint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible High-Voltage Support:\u003c\/strong\u003e Operates across 120 VAC\/125 VDC or 240 VAC field signal levels using dedicated IOTAs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandardized Hardware Assembly:\u003c\/strong\u003e Utilizes a single IOM architecture across different line voltages to minimize spare parts inventory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Features optical isolation providing 1500 VAC RMS or +\/-1500 VDC isolation between field wiring and logic common.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Redundancy Options:\u003c\/strong\u003e Supports non-redundant and redundant IOTA configurations for fault-tolerant automation architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e Incorporates internal hardware self-testing to maintain signal transmission integrity and reliable state reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Logic:\u003c\/strong\u003e Supports direct and reverse input state interpretation per channel to adapt to plant switch logic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Voltage Contact Monitoring:\u003c\/strong\u003e Sensing discrete status from motor control centers (MCC), circuit breakers, and auxiliary relay contacts operating at 120 VAC, 125 VDC, or 240 VAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlant Interlock Processing:\u003c\/strong\u003e Integrating hardwired field safety switches and process interlocks directly into C300 control strategies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubstation and Electrical Interface:\u003c\/strong\u003e Interfacing 125 VDC substation signals and utility status points into the Experion DCS.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-PDIH01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input High Voltage Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform \/ Family\u003c\/td\u003e\n\u003ctd\u003eExperion Series-C I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC RMS or +\/-1500 VDC (field to logic common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Technique\u003c\/td\u003e\n\u003ctd\u003eOptical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Redundant 120 VAC\/125 VDC IOTA\u003c\/td\u003e\n\u003ctd\u003eCC-TDI110 (9 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant 120 VAC\/125 VDC IOTA\u003c\/td\u003e\n\u003ctd\u003eCC-TDI120 (12 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Redundant 240 VAC IOTA\u003c\/td\u003e\n\u003ctd\u003eCC-TDI220 (9 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant 240 VAC IOTA\u003c\/td\u003e\n\u003ctd\u003eCC-TDI230 (12 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120 VAC Operating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e90 to 132 VAC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e125 VDC Operating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e100 to 138 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e240 VAC Operating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e180 to 264 VAC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Frequency Range\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120 VAC Sense Current (ON)\u003c\/td\u003e\n\u003ctd\u003e7.5 mA RMS min @ 90V RMS; 10 mA RMS @ 132V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e125 VDC Sense Current (ON)\u003c\/td\u003e\n\u003ctd\u003e1.2 mA min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e240 VAC Sense Current (ON)\u003c\/td\u003e\n\u003ctd\u003e1.11 mA RMS min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120 VAC Sense Current (OFF)\u003c\/td\u003e\n\u003ctd\u003e2.0 mA RMS max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e125 VDC \/ 240 VAC Sense Current (OFF)\u003c\/td\u003e\n\u003ctd\u003e0.32 mA \/ 0.32 mA RMS max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120 VAC Pick-Up Voltage (ON)\u003c\/td\u003e\n\u003ctd\u003e90 VAC RMS min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e125 VDC Pick-Up Voltage (ON)\u003c\/td\u003e\n\u003ctd\u003e100 VDC min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e240 VAC Pick-Up Voltage (ON)\u003c\/td\u003e\n\u003ctd\u003e180 VAC RMS min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop-Out Voltage (OFF Max)\u003c\/td\u003e\n\u003ctd\u003e20 VAC RMS (120V) \/ 25 VDC (125V) \/ 50 VAC RMS (240V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Delay \/ Response Time\u003c\/td\u003e\n\u003ctd\u003e25 ms max (120\/240 VAC); 10 ms max (125 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIOTA Model\u003c\/th\u003e\n\u003cth\u003eVoltage Application\u003c\/th\u003e\n\u003cth\u003eConfiguration Type\u003c\/th\u003e\n\u003cth\u003eBoard Size\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-TDI110\u003c\/td\u003e\n\u003ctd\u003e120 VAC \/ 125 VDC\u003c\/td\u003e\n\u003ctd\u003eNon-Redundant\u003c\/td\u003e\n\u003ctd\u003e9 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-TDI120\u003c\/td\u003e\n\u003ctd\u003e120 VAC \/ 125 VDC\u003c\/td\u003e\n\u003ctd\u003eRedundant\u003c\/td\u003e\n\u003ctd\u003e12 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-TDI220\u003c\/td\u003e\n\u003ctd\u003e240 VAC\u003c\/td\u003e\n\u003ctd\u003eNon-Redundant\u003c\/td\u003e\n\u003ctd\u003e9 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-TDI230\u003c\/td\u003e\n\u003ctd\u003e240 VAC\u003c\/td\u003e\n\u003ctd\u003eRedundant\u003c\/td\u003e\n\u003ctd\u003e12 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that field signal levels (120 VAC, 125 VDC, or 240 VAC) match the specific IOTA installed (e.g., CC-TDI110\/120 or CC-TDI220\/230).\u003c\/li\u003e\n\u003cli\u003eVerify that power to field sensing circuits and the IOTA carrier bus is switched off before mounting hardware.\u003c\/li\u003e\n\u003cli\u003eSecurely mount the IOTA onto the cabinet carrier assembly.\u003c\/li\u003e\n\u003cli\u003eAlign the CC-PDIH01 module with the edge connectors on the IOTA and push firmly into place until seated.\u003c\/li\u003e\n\u003cli\u003eTerminate high-voltage field wiring into the detachable screw terminal blocks on the IOTA, ensuring appropriate wire gauge and field grounding principles are followed.\u003c\/li\u003e\n\u003cli\u003eApply logic power to the IOTA carrier bus and field excitation voltage to test channel status indications.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfigure input channels within Experion Control Builder under the corresponding C300 controller I\/O tree.\u003c\/li\u003e\n\u003cli\u003eSelect the channel direction (Direct or Reverse) according to field contact state specifications.\u003c\/li\u003e\n\u003cli\u003eFor redundant IOTA setups (e.g., CC-TDI120), assign the primary and secondary CC-PDIH01 modules to the same IOTA address slot to enable switchover functionality.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668004172139,"sku":"CC-TDI120","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-tdi120-digital-input-module-zfvjv3j4oui_df06f03a-08fe-46c2-ac25-e0bff6bae6eb.jpg?v=1765505034","url":"https:\/\/www.plcprotech.com\/products\/honeywell-cc-pdih01-experion-series-c-digital-input-high-voltage-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}