{"product_id":"honeywell-cc-pdod51-series-c-24vdc-digital-output-module-sink-open-drain-coated","title":"Honeywell CC-PDOD51 Series C 24VDC Digital Output Module SINK Open Drain Coated","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PDOD51\u003c\/strong\u003e is a 32-channel, 24VDC digital output module designed for process switching applications within the Experion C300 Series C I\/O architecture. Functioning as an open-drain SINK-type output card, this module allows the system to switch field loads by pulling the return path to ground, operating seamlessly with user-supplied field power supplies up to 30 VDC. The assembly comes conformal coated to protect internal electronic circuits against corrosive elements and harsh environmental contaminants commonly found in industrial processing plants.\u003c\/p\u003e\n\u003cp\u003eDesigned for cabinet density and reliable execution in DCS installations, the \u003cstrong\u003eCC-PDOD51\u003c\/strong\u003e plugs directly into its designated Input Output Termination Assembly (IOTA). It eliminates the need for separate chassis housing, receiving its operational logic power directly through the carrier bus. The module features integrated electronic overcurrent protection on every channel, eliminating the maintenance overhead associated with traditional inline fuses. It also provides configurable safe-state (FAILOPT) behaviors, enabling each output channel to either hold its last value or shed to a predetermined safe value in the event of system communication loss or controller failure.\u003c\/p\u003e\n\u003cp\u003eOperating across 32 discrete output channels, the module supports flexible switching functions including latched, pulsed, and pulse-width modulated (PWM) outputs. To preserve signal integrity between field circuits and control logic, the \u003cstrong\u003eHoneywell CC-PDOD51\u003c\/strong\u003e maintains 1000 VAC RMS galvanic isolation between field power loops and the core system backplane. When deployed on redundant IOTA base units, the hardware delivers seamless switchover capability with zero output current gap, ensuring continuous process operations for critical actuators, interposing relays, and solenoid valves.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e32-Channel SINK Configuration:\u003c\/strong\u003e Operates as an open-drain discrete output card designed to switch 24VDC field loads up to 0.1 A per channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e Factory-coated internal circuitry provides resistance against airborne pollutants, industrial moisture, and corrosive atmospheric contaminants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Overcurrent Protection:\u003c\/strong\u003e Features integrated current-limiting hardware to safeguard field wiring and channel drivers without requiring physical fuses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Safe-State (FAILOPT):\u003c\/strong\u003e Allows per-channel programming to either Hold Last Value or Shed to Safe Value during system communication faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Switching Modes:\u003c\/strong\u003e Supports latched, pulsed, or pulse-width modulated (PWM) signal generation tailored to process control hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Provides 1000 VAC RMS isolation between field-supplied power circuits and the system architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-Gap Switchover:\u003c\/strong\u003e Eliminates output current dropping (0 ms gap) during redundancy failover when installed on dual-IOM base units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolenoid Valve Actuation:\u003c\/strong\u003e Control and switching of 24VDC pneumatic and hydraulic solenoid coils in process skids.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterposing Relay Logic:\u003c\/strong\u003e Interfacing low-current DCS output signals with higher-voltage motor control centers (MCC) and field equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnnunciator \u0026amp; Pilot Light Control:\u003c\/strong\u003e Driving cabinet status indicators, local alarm horns, and visual display panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Skid Integration:\u003c\/strong\u003e Switching discrete actuators and equipment run\/stop commands within Experion C300 control networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eCC-PDOD51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eSeries C I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSINK Type 24VDC Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Coating\u003c\/td\u003e\n\u003ctd\u003eCoated (Conformal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eInput \/ Output Characteristics\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSINK (Open Drain)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Voltage\u003c\/td\u003e\n\u003ctd\u003e30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Voltage\u003c\/td\u003e\n\u003ctd\u003e15 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e0.1 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003e0 VDC (at 0.1 A max load current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e100 uA (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn-On \/ Turn-Off Time\u003c\/td\u003e\n\u003ctd\u003e10 ms (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitchover Gap (Redundancy)\u003c\/td\u003e\n\u003ctd\u003e0 ms (None)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Functions\u003c\/td\u003e\n\u003ctd\u003eLatched, Pulsed, Pulse-Width Modulated (per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical \u0026amp; Isolation\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e1000 VAC RMS (System-to-Field isolation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eUser-supplied field power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eElectronic overcurrent protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eIOTA Compatibility\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Redundant IOTA Model\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"products\/honeywell-cc-tdod51-experion-series-c-non-redundant-digital-output-iota\"\u003eCC-TDOD51 (9-inch \/ 228 mm)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant IOTA Model\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/honeywell-cc-tdod61-51307089-175-experion-series-c-12-inch-redundant-digital-output-iota\"\u003eCC-TDOD61 (12-inch \/ 304 mm)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Inspection:\u003c\/strong\u003e Verify the module part number (CC-PDOD51) and check that the physical enclosure and connector pins show no shipping damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIOTA Mounting:\u003c\/strong\u003e Ensure the target IOTA (CC-TDOD51 or CC-TDOD61) is securely installed onto the cabinet enclosure rails and properly bonded to system ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Power Wiring:\u003c\/strong\u003e Connect the external 24VDC user field power supply to the designated terminals on the IOTA assembly, maintaining correct polarity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Load Termination:\u003c\/strong\u003e Land field wiring onto the detachable two-level IOTA terminal blocks. Ensure wire sizes do not exceed 12 AWG (2.5 mm stranded).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Align the CC-PDOD51 module with the guide connectors on the IOTA and press firmly until the locking mechanism engages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding \u0026amp; Shielding:\u003c\/strong\u003e Confirm overall cabinet ground continuity to prevent common-mode voltage fluctuations from impacting field circuits.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \u0026amp; Commissioning\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Parameterization:\u003c\/strong\u003e Assign individual channel operation parameters (latched, pulsed, or PWM) within the Experion Engineering Studio environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFAILOPT Behavior Setup:\u003c\/strong\u003e Configure safe-state parameters on a per-channel basis, defining whether outputs hold their last valid state or transition to a safe zero\/off condition upon system failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Loop Testing:\u003c\/strong\u003e Perform point-to-point output verification from the control software, observing channel switching performance and load current across active field devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Verification:\u003c\/strong\u003e If installed in a dual-module configuration on a CC-TDOD61 IOTA, perform a manual failover check to ensure continuous load state retention without signal interruption.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52679444037995,"sku":"CC-PDOD51","price":1500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CC-PDOD51_003_1200x1200_38a9e78a-23a3-40c9-b819-1179d27f04c9.jpg?v=1786760151","url":"https:\/\/www.plcprotech.com\/products\/honeywell-cc-pdod51-series-c-24vdc-digital-output-module-sink-open-drain-coated","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}